Computed tomography imaging with the Adaptive Statistical Iterative Reconstruction (ASIR) algorithm: dependence of image quality on the blending level of reconstruction

被引:18
作者
Barca, Patrizio [1 ,2 ]
Giannelli, Marco [3 ]
Fantacci, Maria Evelina [1 ,2 ]
Caramella, Davide [4 ]
机构
[1] Univ Pisa, Dept Phys, Pisa, Italy
[2] INFN, Pisa Sect, Pisa, Italy
[3] Azienda Osped Univ Pisana, Pisa Univ Hosp, Unit Med Phys, Via Roma 67, I-56126 Pisa, Italy
[4] Univ Pisa, Diagnost & Intervent Radiol, Pisa, Italy
关键词
Computed tomography; Adaptive Statistical Iterative Reconstruction; Image quality; Noise; Modulation transfer function; NOISE-POWER SPECTRUM; DOSE REDUCTION; CT; MODEL; RESOLUTION; SYSTEM; SNR;
D O I
10.1007/s13246-018-0645-8
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Computed tomography (CT) is a useful and widely employed imaging technique, which represents the largest source of population exposure to ionizing radiation in industrialized countries. Adaptive Statistical Iterative Reconstruction (ASIR) is an iterative reconstruction algorithm with the potential to allow reduction of radiation exposure while preserving diagnostic information. The aim of this phantom study was to assess the performance of ASIR, in terms of a number of image quality indices, when different reconstruction blending levels are employed. CT images of the Catphan-504 phantom were reconstructed using conventional filtered back-projection (FBP) and ASIR with reconstruction blending levels of 20, 40, 60, 80, and 100%. Noise, noise power spectrum (NPS), contrast-to-noise ratio (CNR) and modulation transfer function (MTF) were estimated for different scanning parameters and contrast objects. Noise decreased and CNR increased non-linearly up to 50 and 100%, respectively, with increasing blending level of reconstruction. Also, ASIR has proven to modify the NPS curve shape. The MTF of ASIR reconstructed images depended on tube load/contrast and decreased with increasing blending level of reconstruction. In particular, for low radiation exposure and low contrast acquisitions, ASIR showed lower performance than FBP, in terms of spatial resolution for all blending levels of reconstruction. CT image quality varies substantially with the blending level of reconstruction. ASIR has the potential to reduce noise whilst maintaining diagnostic information in low radiation exposure CT imaging. Given the opposite variation of CNR and spatial resolution with the blending level of reconstruction, it is recommended to use an optimal value of this parameter for each specific clinical application.
引用
收藏
页码:463 / 473
页数:11
相关论文
共 39 条
[1]  
[Anonymous], 2014, 180 EUR COMM
[2]  
Argaud C, 2012, ASIR NEW RECONSTRUCT
[3]   Dual energy CT with photon counting and dual source systems: comparative evaluation [J].
Atak, Haluk ;
Shikhaliev, Polad M. .
PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (23) :8949-8975
[4]   Iterative reconstruction methods in X-ray CT [J].
Beister, Marcel ;
Kolditz, Daniel ;
Kalender, Willi A. .
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2012, 28 (02) :94-108
[5]   Characterization of adaptive statistical iterative reconstruction algorithm for dose reduction in CT: A pediatric oncology perspective [J].
Brady, S. L. ;
Yee, B. S. ;
Kaufman, R. A. .
MEDICAL PHYSICS, 2012, 39 (09) :5520-5531
[6]   Material-specific transfer function model and SNR in CT [J].
Brunner, Claudia C. ;
Kyprianou, Iacovos S. .
PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (20) :7447-7461
[7]   Performance evaluation of iterative reconstruction algorithms for achieving CT radiation dose reduction - a phantom study [J].
Dodge, Cristina T. ;
Tamm, Eric P. ;
Cody, Dianna D. ;
Liu, Xinming ;
Jensen, Corey T. ;
Wei, Wei ;
Kundra, Vikas ;
Rong, X. John .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (02) :511-531
[8]   A simple approach to measure computed tomography (CT) modulation transfer function (MTF) and noise-power spectrum (NPS) using the American College of Radiology (ACR) accreditation phantom [J].
Friedman, Saul N. ;
Fung, George S. K. ;
Siewerdsen, Jeffrey H. ;
Tsui, Benjamin M. W. .
MEDICAL PHYSICS, 2013, 40 (05)
[9]   Investigation into image quality and dose for different patient geometries with multiple cone-beam CT systems [J].
Gardner, Stephen J. ;
Studenski, Matthew T. ;
Giaddui, Tawfik ;
Cui, Yunfeng ;
Galvin, James ;
Yu, Yan ;
Xiao, Ying .
MEDICAL PHYSICS, 2014, 41 (03)
[10]   Dose reduction in 64-row whole-body CT in multiple trauma: an optimized CT protocol with iterative image reconstruction on a gemstone-based scintillator [J].
Geyer, Lucas L. ;
Koerner, Markus ;
Harrieder, Andreas ;
Mueck, Fabian G. ;
Deak, Zsuzsanna ;
Wirth, Stefan ;
Linsenmaier, Ulrich .
BRITISH JOURNAL OF RADIOLOGY, 2016, 89 (1061)