共 53 条
Determination of organophosphorus flame retardants in fish by pressurized liquid extraction using aqueous solutions and solid-phase microextraction coupled with gas chromatography-flame photometric detector
被引:47
作者:
Gao, Zhanqi
[1
,2
,3
]
Den, Yuehua
[1
]
Yuan, Wenting
[1
]
He, Huan
[1
]
Yang, Shaogui
[1
]
Sun, Cheng
[1
]
机构:
[1] Nanjing Univ, Sch Environm, State Key Lab Pollut Control & Resource Reuse, Nanjing 210023, Jiangsu, Peoples R China
[2] State Environm Protect Key Lab Monitoring & Anal, Nanjing 210036, Jiangsu, Peoples R China
[3] Environm Monitoring Ctr Jiangsu Prov, Nanjing 210036, Jiangsu, Peoples R China
基金:
国家教育部博士点专项基金资助;
中国国家自然科学基金;
中国博士后科学基金;
美国国家科学基金会;
关键词:
Organophosphorus flame retardants;
Pressurized liquid extraction;
Aqueous solutions;
Solid-phase microextraction;
Fish;
ACCELERATED SOLVENT-EXTRACTION;
HOT-WATER EXTRACTION;
MICROWAVE-ASSISTED EXTRACTION;
MASS-SPECTROMETRY;
ORGANOCHLORINE PESTICIDES;
INDOOR DUST;
PLASTICIZERS;
ESTERS;
CLEANUP;
ANTIMICROBIALS;
D O I:
10.1016/j.chroma.2014.09.028
中图分类号:
Q5 [生物化学];
学科分类号:
071010 ;
081704 ;
摘要:
A novel method was developed for the determination of organophosphorus flame retardants (PFRs) in fish. The method consists of a combination of pressurized liquid extraction (PLE) using aqueous solutions and solid-phase microextraction (SPME), followed by gas chromatography-flame photometric detector (GC-FPD). The experimental parameters that influenced extraction efficiency were systematically evaluated. The optimal responses were observed by extracting 1 g of fish meat with the solution of water:acetonitrile (90:10, v/v) at 150 degrees C for 5 min and acid-washed silica gel used as lipid sorbent. The obtained extract was then analyzed by SPME coupled with GC-FPD without any additional clean-up steps. Under the optimal conditions, the proposed procedure showed a wide linear range (0.90-5000 ng g(-1)) obtained by analyzing the spiked fish samples with increasing concentrations of PFRs and correlation coefficient (R) ranged from 0.9900 to 0.9992. The detection limits (S/N = 3) were in the range of 0.010-0.208 ng g(-1) with standard deviations (RSDs) ranging from 2.0% to 9.0%. The intra-day and inter-day variations were less than 9.0% and 7.8%, respectively. The proposed method was successfully applied to the determination of PFRs in real fish samples with recoveries varying from 79.8% to 107.3%. The results demonstrate that the proposed method is highly effective for analyzing PFRs in fish samples. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:31 / 37
页数:7
相关论文