Investigating the ocular temperature rise during femtosecond laser lens fragmentation: an in vitro study

被引:6
作者
Mencucci, Rita [1 ]
Matteoli, Sara [2 ]
Corvi, Andrea [2 ]
Terracciano, Luca [1 ]
Favuzza, Eleonora [1 ]
Gherardini, Stefano [3 ]
Caruso, Filippo [4 ]
Bellucci, Roberto [5 ]
机构
[1] Univ Florence, Eye Clin, Dept Surg & Translat Med, I-50134 Florence, Italy
[2] Univ Florence, Dept Ind Engn, I-50134 Florence, Italy
[3] Univ Florence, Dept Informat Engn, CSDC, INFN, I-50134 Florence, Italy
[4] Univ Florence, Dept Phys & Astron, LENS, QSTAR, I-50134 Florence, Italy
[5] Univ Hosp, Ophthalm Unit, Verona, Italy
关键词
Cataract; Eye temperature; Femtosecond laser; Femtosecond laser-assisted cataract surgery; ASSISTED CATARACT-SURGERY; PHACOEMULSIFICATION; IOL;
D O I
10.1007/s00417-015-3196-7
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
To investigate the trend of temperature variation during lens fragmentation simulated by a femtosecond laser on an in vitro eye model. In our experimental study, a convex cylinder of gelatinous material, usually employed in femtosecond laser calibration, was used to simulate both an anterior segment and a crystalline lens during fragmentation performed with the Victus femtosecond laser (Technolas Perfect Vision GmbH, Germany; Bausch + Lomb Incorporated, USA). Two radiated energies (7000 nJ and 9000 nJ) and three cutting patterns (crosses, circles and cross + circle) were applied. Trends of temperature variation as a function of time were obtained using a T-type thermocouple. The maximum value of temperature rise during lens fragmentation ranged from 3.53 to 5.13 A degrees C; the rise was directly proportional to the intensity of the radiated energy (7000 nJ or 9000 nJ) and the cutting pattern performed. This behavior was experimentally represented by an asymmetric function with a characteristic bell curve shape, whereas it was mathematically described by a transport diffusive model. Since the temperature rise at the fragmentation volume base resulted to be around 5 A degrees C in our in vitro study, lens fragmentation performed using the Victus femtosecond laser might be considered safe form a thermal point of view.
引用
收藏
页码:2203 / 2210
页数:8
相关论文
共 50 条
  • [21] Direct observation of the temperature field during ablation of materials by multiple femtosecond laser pulses
    Tran, D. V.
    Lam, Y. C.
    Zheng, H. Y.
    Wong, B. S.
    Hardt, D. E.
    APPLIED SURFACE SCIENCE, 2007, 253 (17) : 7290 - 7294
  • [22] Preoperative intraocular pressure as a strong predictive factor for intraocular pressure rise during vacuum application in femtosecond laser-assisted cataract surgery
    Mariacher, Siegfried
    Laubichler, Peter
    Wendelstein, Jascha
    Mariacher, Martina
    Bolz, Matthias
    ACTA OPHTHALMOLOGICA, 2019, 97 (08) : E1123 - E1129
  • [23] Comparison of cumulative dispersed energy between conventional phacoemulsification and femtosecond laser-assisted cataract surgery with two different lens fragmentation patterns
    Hung-Yuan Lin
    Shu-Ting Kao
    Ya-Jung Chuang
    Shuan Chen
    Pi-Jung Lin
    Lasers in Medical Science, 2022, 37 : 843 - 848
  • [24] Comparison of cumulative dispersed energy between conventional phacoemulsification and femtosecond laser-assisted cataract surgery with two different lens fragmentation patterns
    Lin, Hung-Yuan
    Kao, Shu-Ting
    Chuang, Ya-Jung
    Chen, Shuan
    Lin, Pi-Jung
    LASERS IN MEDICAL SCIENCE, 2022, 37 (02) : 843 - 848
  • [25] The Effect of Femtosecond Laser Treatment on the Effectiveness of Resin-Zirconia Adhesive: An In Vitro Study
    Vicente Prieto, Maria
    Caseiro Gomes, Ana Luisa
    Montero Martin, Javier
    Alvarado Lorenzo, Alfonso
    Seoane Mato, Vicente
    Albaladejo Martinez, Alberto
    JOURNAL OF LASERS IN MEDICAL SCIENCES, 2016, 7 (04) : 214 - 219
  • [26] Mechanical protective effect of lens anterior capsule disc on corneal endothelial cells during femtosecond laser-assisted cataract surgery in a rabbit model
    Wu, Bowen
    Ding, Xue
    Li, Shaowei
    Huo, Dongmei
    Zhang, Fan
    Liang, Weiyan
    Li, Ling
    Dou, Zexia
    BMC OPHTHALMOLOGY, 2023, 23 (01)
  • [27] An In Vitro Study on Focusing fs-Laser Pulses Into Ocular Media for Ophthalmic Surgery
    Merker, Marina
    Ackermann, Roland
    Kammel, Robert
    Kunert, Kathleen S.
    Nolte, Stefan
    LASERS IN SURGERY AND MEDICINE, 2013, 45 (09) : 589 - 596
  • [28] Standard manual capsulorhexis / Ultrasound phacoemulsification compared to femtosecond laser-assisted capsulorhexis and lens fragmentation in clear cornea small incision cataract surgery
    Kanellopoulos, Anastasios John
    Asimellis, George
    EYE AND VISION, 2016, 3
  • [29] Measurement of the temperature increase in the porcine cadaver iris during direct illumination by femtosecond laser pulses
    Sun, Hui
    Kurtz, Ronald M.
    Juhasz, Tibor
    OPTICAL INTERACTIONS WITH TISSUES AND CELLS XXI, 2010, 7562
  • [30] Temperature effects on the geometry during the formation of micro-holes fabricated by femtosecond laser in PMMA
    Zhang, Fan
    Dong, Xinran
    Yin, Kai
    Song, Yuxin
    Tian, Yaxiang
    Wang, Cong
    Duan, Ji'an
    OPTICS AND LASER TECHNOLOGY, 2018, 100 : 256 - 260