Investigating the ocular temperature rise during femtosecond laser lens fragmentation: an in vitro study

被引:6
|
作者
Mencucci, Rita [1 ]
Matteoli, Sara [2 ]
Corvi, Andrea [2 ]
Terracciano, Luca [1 ]
Favuzza, Eleonora [1 ]
Gherardini, Stefano [3 ]
Caruso, Filippo [4 ]
Bellucci, Roberto [5 ]
机构
[1] Univ Florence, Eye Clin, Dept Surg & Translat Med, I-50134 Florence, Italy
[2] Univ Florence, Dept Ind Engn, I-50134 Florence, Italy
[3] Univ Florence, Dept Informat Engn, CSDC, INFN, I-50134 Florence, Italy
[4] Univ Florence, Dept Phys & Astron, LENS, QSTAR, I-50134 Florence, Italy
[5] Univ Hosp, Ophthalm Unit, Verona, Italy
关键词
Cataract; Eye temperature; Femtosecond laser; Femtosecond laser-assisted cataract surgery; ASSISTED CATARACT-SURGERY; PHACOEMULSIFICATION; IOL;
D O I
10.1007/s00417-015-3196-7
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
To investigate the trend of temperature variation during lens fragmentation simulated by a femtosecond laser on an in vitro eye model. In our experimental study, a convex cylinder of gelatinous material, usually employed in femtosecond laser calibration, was used to simulate both an anterior segment and a crystalline lens during fragmentation performed with the Victus femtosecond laser (Technolas Perfect Vision GmbH, Germany; Bausch + Lomb Incorporated, USA). Two radiated energies (7000 nJ and 9000 nJ) and three cutting patterns (crosses, circles and cross + circle) were applied. Trends of temperature variation as a function of time were obtained using a T-type thermocouple. The maximum value of temperature rise during lens fragmentation ranged from 3.53 to 5.13 A degrees C; the rise was directly proportional to the intensity of the radiated energy (7000 nJ or 9000 nJ) and the cutting pattern performed. This behavior was experimentally represented by an asymmetric function with a characteristic bell curve shape, whereas it was mathematically described by a transport diffusive model. Since the temperature rise at the fragmentation volume base resulted to be around 5 A degrees C in our in vitro study, lens fragmentation performed using the Victus femtosecond laser might be considered safe form a thermal point of view.
引用
收藏
页码:2203 / 2210
页数:8
相关论文
共 50 条
  • [1] Investigating the ocular temperature rise during femtosecond laser lens fragmentation: an in vitro study
    Rita Mencucci
    Sara Matteoli
    Andrea Corvi
    Luca Terracciano
    Eleonora Favuzza
    Stefano Gherardini
    Filippo Caruso
    Roberto Bellucci
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2015, 253 : 2203 - 2210
  • [2] Intraocular Lens Fragmentation Using Femtosecond Laser: An In Vitro Study
    Bala, Chandra
    Shi, Jeffrey
    Meades, Kerrie
    TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2015, 4 (03):
  • [3] Posterior capsule dynamics during femtosecond laser lens fragmentation
    Bellucci, Carlo
    Mora, Paolo
    Tedesco, Salvatore Antonio
    Bellucci, Roberto
    Gandolfi, Stefano
    INTERNATIONAL OPHTHALMOLOGY, 2023, 43 (09) : 3339 - 3343
  • [4] Posterior capsule dynamics during femtosecond laser lens fragmentation
    Carlo Bellucci
    Paolo Mora
    Salvatore Antonio Tedesco
    Roberto Bellucci
    Stefano Gandolfi
    International Ophthalmology, 2023, 43 : 3339 - 3343
  • [5] In vitro experiment study on ablation parameters in femtosecond laser-ocular tissue interaction
    Ngoi, K. A.
    Hou, D. X.
    Hoh, S. T.
    Koh, L. H. K.
    Deng, Y. Z.
    INTERNATIONAL JOURNAL OF NANOSCIENCE, VOL 4, NO 4, 2005, 4 (04): : 483 - 488
  • [6] Behavior of Generated Gas during Femtosecond Laser Lens Irradiation in Porcine Cadaver Eyes
    Masuda, Yoichiro
    Oki, Kotaro
    Watanabe, Akira
    Ohkido, Makiko
    Iwaki, Hisaharu
    Shiba, Takuya
    Nakano, Tadashi
    APPLIED SCIENCES-BASEL, 2021, 11 (17):
  • [7] Effect of numerical aperture of a femtosecond laser system on the required pulse energy for capsulotomy and lens fragmentation
    Campos, Michael
    Dennison, Anthony
    Fu, Hong
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [8] Crystalline lens photodisruption using femtosecond laser: Experimental study
    Chatoux, O.
    Touboul, D.
    Buestel, C.
    Balcou, P.
    Colin, J.
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2010, 33 (07): : 472 - 480
  • [9] Effect of femtosecond laser-assisted lens surgery on posterior capsule opacification in the human capsular bag in vitro
    Wertheimer, Christian
    Kreutzer, Thomas C.
    Dirisamer, Martin
    Eibl-Lindner, Kirsten
    Kook, Daniel
    Priglinger, Siegfried
    Mayer, Wolfgang J.
    ACTA OPHTHALMOLOGICA, 2017, 95 (02) : E85 - E88
  • [10] An in vitro study of femtosecond laser photodisruption in rabbit sclera
    Jiang F.
    Yang X.
    Dai N.
    Lu P.
    Long H.
    Cui L.
    Frontiers of Optoelectronics in China, 2008, 1 (1-2): : 162 - 167