The effect of dual frequency cyclic compression on matrix deposition by osteoblast-like cells grown in 3D scaffolds and on modulation of VEGF variant expression

被引:51
作者
Dumas, Virginie [1 ,2 ]
Perrier, Anthony [1 ,2 ]
Malaval, Luc [1 ,2 ]
Laroche, Norbert [1 ,2 ]
Guignandon, Alain [1 ,2 ]
Vico, Laurence [1 ,2 ]
Rattner, Aline [1 ,2 ]
机构
[1] INSERM, U890, Lab Biol Tissu Osseux, IFR143, F-42023 St Etienne 2, France
[2] Univ Lyon, F-42023 St Etienne, France
关键词
Bone tissue engineering/osseointegration; Osteoblast; ECM (extracellular matrix); Growth factors; Hydroxyapatite; Mechanical test/strain rate; ENGINEERING THICK TISSUES; MECHANICAL STRAIN; IN-VITRO; ENDOTHELIAL-CELLS; BONE REGENERATION; TRABECULAR BONE; VASCULARIZATION PROBLEM; GENE-EXPRESSION; STEM-CELLS; OSTEOGENESIS;
D O I
10.1016/j.biomaterials.2009.02.048
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
As a strategy to optimise osteointegration of biomaterials by inducing proper extracellular matrix synthesis, and specifically angiogenic growth factor production and storage, we tested the effects of cyclic mechanical compression on 3D cultures of human osteoblast-like cells. MG-63 cells were seeded into 3D porous hydroxyrapatite ceramics under vacuum to enable a homogenous cellular distribution. A four-day culture period allowed cell proliferation throughout the scaffolds. Low amplitude cyclic compressions were then applied to the scaffolds for 15 min with different regimens generated by the ZetOS (TM) system. A 3 Hz sinusoidal (sine) signal increased slightly collagen and fibronectin expression. When 50 Hz or 100 Hz vibrations were superimposed to the 3 Hz signal, matrix protein expression was down-regulated. In contrast, adding a 25 Hz vibration up-regulated significantly collagen and fibronectin. Moreover, expression of a matrix-bound variant of vascular endothelial growth factor-A (VEGF-A) was specifically stimulated compared to control or 3 Hz sine, and non-soluble VEGF protein was increased. Our study enabled us to identify low-amplitude, high-frequency strain regimen able to increase major matrix proteins of bone tissue and to regulate the expression of VEGF variants, showing that an appropriate combined loading has the potential to functionalise cellularized bone-like constructs. (C) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:3279 / 3288
页数:10
相关论文
共 45 条
[1]  
Amoroso A, 1997, Eur Rev Med Pharmacol Sci, V1, P17
[2]  
Barrère F, 2006, INT J NANOMED, V1, P317
[3]   Uniaxial mechanical strain:: An in vitro correlate to distraction osteogenesis [J].
Bhatt, Kirit A. ;
Chang, Eric I. ;
Warren, Stephen M. ;
Lin, Shin-e ;
Bastidas, Nicholas ;
Ghali, Shadi ;
Thibboneir, Aurelia ;
Capla, Jennifer M. ;
McCarthy, Joseph G. ;
Gurtner, Geoffrey C. .
JOURNAL OF SURGICAL RESEARCH, 2007, 143 (02) :329-336
[4]   ARE MG-63 AND HOS TE85 HUMAN OSTEOSARCOMA CELL-LINES REPRESENTATIVE MODELS OF THE OSTEOBLASTIC PHENOTYPE [J].
CLOVER, J ;
GOWEN, M .
BONE, 1994, 15 (06) :585-591
[5]   Ex vivo bone formation in bovine trabecular bone cultured in a dynamic 3D bioreactor is enhanced by compressive mechanical strain [J].
David, Valentin ;
Guignandon, Alain ;
Martin, Aline ;
Malaval, Luc ;
Lafage-Proust, Marie-Helene ;
Rattner, Aline ;
Mann, Val ;
Noble, Brendon ;
Jones, David B. ;
Vico, Laurence .
TISSUE ENGINEERING PART A, 2008, 14 (01) :117-126
[6]   Mechanical signals modulated vascular endothelial growth factor-A (VEGF-A) alternative splicing in osteoblastic cells through actin polymerisation [J].
Faure, Celine ;
Linossier, Marie-Therese ;
Malaval, Luc ;
Lafage-Proust, Marie-Helene ;
Peyroche, Sylvie ;
Vico, Laurence ;
Guignandon, Alain .
BONE, 2008, 42 (06) :1092-1101
[7]   Quantifying the strain history of bone: spatial uniformity and self-similarity of low-magnitude strains [J].
Fritton, SP ;
McLeod, KJ ;
Rubin, CT .
JOURNAL OF BIOMECHANICS, 2000, 33 (03) :317-325
[8]   THE VASCULAR ENDOTHELIAL GROWTH-FACTOR FAMILY - IDENTIFICATION OF A 4TH MOLECULAR-SPECIES AND CHARACTERIZATION OF ALTERNATIVE SPLICING OF RNA [J].
HOUCK, KA ;
FERRARA, N ;
WINER, J ;
CACHIANES, G ;
LI, B ;
LEUNG, DW .
MOLECULAR ENDOCRINOLOGY, 1991, 5 (12) :1806-1814
[9]   Effects of loading frequency on mechanically induced bone formation [J].
Hsieh, YF ;
Turner, CH .
JOURNAL OF BONE AND MINERAL RESEARCH, 2001, 16 (05) :918-924
[10]  
Jones D. B., 2003, European Cells & Materials, V5, P48