No benefits with computer assistance in triple pelvic osteotomy

被引:5
作者
Pakvis, D [1 ]
van Hellemondt, G [1 ]
Anderson, P [1 ]
de Kleuver, M [1 ]
机构
[1] St Maartens Clin, Dept Orthopaed, NL-6500 GM Nijmegen, Netherlands
来源
ACTA ORTHOPAEDICA SCANDINAVICA | 2004年 / 75卷 / 03期
关键词
D O I
10.1080/00016470410001187
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We evaluated computer-assisted surgery (CAS) used for 21 triple pelvic osteotomies on 20 patients with symptomatic acetabular dysplasia and compared the intraoperative and immediate postoperative data with those of 32 patients who underwent 40 pelvic osteotomies without CAS. The use of the CAS system was abandoned during 9/21 operations mostly because of technical and CT data failure. The peroperative blood loss and duration of surgery were greater, while neurovascular damage occurred less often in the CAS group. We found that the CAS system for pelvic osteotomy was not better than conventional methods.
引用
收藏
页码:265 / 268
页数:4
相关论文
共 19 条
[1]  
Berlemann U, 1997, ORTHOPADE, V26, P463
[2]   CT and MR imaging of the hip [J].
Conway, WF ;
Totty, WG ;
McEnery, KW .
RADIOLOGY, 1996, 198 (02) :297-307
[3]  
DALAUNAY S, 1997, SKELETAL RADIOL, V26, P75
[4]   Three-dimensional displacement of the hip joint after triple pelvic osteotomy - A postmortem radiostereometric study [J].
de Kleuver, M ;
Huiskes, R ;
Kauer, JMG ;
Veth, RPH .
ACTA ORTHOPAEDICA SCANDINAVICA, 1998, 69 (06) :585-589
[5]  
GANZ R, 1988, CLIN ORTHOP RELAT R, P26
[7]  
KLAUE K, 1988, CLIN ORTHOP RELAT R, V232, P235
[8]   Accuracy of pedicle screw insertion with and without computer assistance: a randomised controlled clinical study in 100 consecutive patients [J].
Laine, T ;
Lund, T ;
Ylikoski, M ;
Lohikoski, J ;
Schlenzka, D .
EUROPEAN SPINE JOURNAL, 2000, 9 (03) :235-240
[9]  
Langlotz F, 1997, Comput Aided Surg, V2, P317, DOI 10.3109/10929089709149831
[10]  
Langlotz F, 1998, CLIN ORTHOP RELAT R, P92