Fault Ride Through Techniques of DFIG-based Wind Energy Systems

被引:0
作者
Fan, Lingling [1 ]
Zhu, Chanxia [2 ,3 ]
Hu, Minqiang [2 ,3 ]
机构
[1] NDSU, Dept Elect & Comp Engn, Fargo, ND 58105 USA
[2] Southeast Univ, Coll Elect Engn, Nanjing 210096, Jiangsu, Peoples R China
[3] NDSU, ECE Dept, Nanjing 210096, Jiangsu, Peoples R China
来源
PROCEEDINGS OF THE 48TH IEEE CONFERENCE ON DECISION AND CONTROL, 2009 HELD JOINTLY WITH THE 2009 28TH CHINESE CONTROL CONFERENCE (CDC/CCC 2009) | 2009年
关键词
FED INDUCTION GENERATOR; TURBINES;
D O I
10.1109/CDC.2009.5400331
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
This paper presents a novel control technique for fault ride through of a DFIG-based wind energy system. Both unbalanced faults and balanced faults are considered. For unbalanced faults, a close to 120 Hz component will be present in the rotor currents. For balanced faults, the rotor currents will experience a surge. The control technique presented in this paper is effective in mitigating the high frequency harmonic components and reducing the surge in the rotor currents. The novelty of the control technique is its simplicity and effectiveness: (i) only one reference transformation (abc/alpha beta) is required and (ii) harmonic filters are not required. Simulations performed in Matlab/Simulink are presented to illustrate the effectiveness of the proposed control strategy.
引用
收藏
页码:6829 / 6834
页数:6
相关论文
共 10 条
[1]   Overview of control and grid synchronization for distributed power generation systems [J].
Blaabjerg, Frede ;
Teodorescu, Remus ;
Liserre, Marco ;
Timbus, Adrian V. .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2006, 53 (05) :1398-1409
[2]   Control of a doubly fed induction wind generator under unbalanced grid voltage conditions [J].
Brekken, Ted K. A. ;
Mohan, Ned .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2007, 22 (01) :129-135
[3]   Modeling and enhanced control of DFIG under unbalanced grid voltage conditions [J].
Hu, Jiabing ;
He, Yikang .
ELECTRIC POWER SYSTEMS RESEARCH, 2009, 79 (02) :273-281
[4]  
Krause P.C., 1994, ANAL ELECT MACHINERY
[5]   Ridethrough of wind turbines with doubly-fed induction generator during a voltage dip [J].
Morren, J ;
de Haan, SWH .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2005, 20 (02) :435-441
[6]   Doubly fed induction generator systems for wind turbines [J].
Müller, S ;
Deicke, M ;
De Doncker, RW .
IEEE INDUSTRY APPLICATIONS MAGAZINE, 2002, 8 (03) :26-33
[7]  
Peña R, 2007, IEEE T ENERGY CONVER, V22, P544, DOI [10.1109/TEC.2006.895393, 10.1109/TEC.2007.895393]
[8]   Proportional-resonant controllers and filters for grid-connected voltage-source converters [J].
Teodorescu, R. ;
Blaabjerg, F. ;
Liserre, M. ;
Loh, P. C. .
IEE PROCEEDINGS-ELECTRIC POWER APPLICATIONS, 2006, 153 (05) :750-762
[9]   Control of a doubly fed induction generator in a wind turbine during grid fault ride-through [J].
Xiang, Dawei ;
Ran, Li ;
Tavner, Peter J. ;
Yang, Shunchang .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2006, 21 (03) :652-662
[10]   Dynamic modeling and control of DFIG-based wind turbines under, unbalanced network conditions [J].
Xu, Lie ;
Wang, Yi .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2007, 22 (01) :314-323