Monte Carlo simulation for Gamma Knife radiosurgery using the Grid

被引:0
作者
Ganesan, Vasu [1 ]
Mehrem, Rami [1 ]
Fenner, John [1 ]
Walton, Lee [1 ]
机构
[1] Royal Hallamshire Hosp, Natl Ctr Stereotact Radiosurg, Sheffield S10 2JF, S Yorkshire, England
来源
RADIOSURGERY, VOL 6 | 2006年 / 6卷
关键词
D O I
10.1159/000093713
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Gamma Knife radiosurgery is an established technique for the treatment of intracranial lesions and vascular malformations in the brain. In this study, dose distributions in a phantom calculated by GammaPlan have been compared with dose distributions computed by a Monte Carlo code (RAPT) assuming the phantom as a homogenous medium. Comparisons have considered both single shot plans and treatment plans. Approximately 200 radiosurgery treatment plans have been simulated using the Monte Carlo method and the initial results are discussed in this paper. The features and application of the GEMSS Grid (cluster of powerful computers) used for our computational work is described here. Analysis of the number of photons required for adequate simulation is also presented. A preliminary study of the effects of in-homogeneity has also been carried out by incorporating a 5 mm thin bone shell into the water phantom and the observed differences in the dose distribution are presented here. MATLAB software has been used to view, overlay and compare the dose distributions. A classical method of visualization of isodose lines and conformity indices has been used to compare and quantify differences. Copyright (c) 2006 S. Karger AG, Basel.
引用
收藏
页码:26 / 35
页数:10
相关论文
共 7 条
[1]   A simplified model of the source channel of the Leksell GammaKnife® tested with PENELOPE [J].
Al-Dweri, FM ;
Lallena, AM ;
Vilches, M .
PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (12) :2687-2703
[2]   Monte Carlo calculation of single-beam dose profiles used in a gamma knife treatment planning system [J].
Cheung, JYC ;
Yu, KN ;
Yu, CP ;
Ho, RTK .
MEDICAL PHYSICS, 1998, 25 (09) :1673-1675
[3]  
Fenner JW, 2005, STUD HEALTH TECHNOL, V112, P190
[4]  
GILL A, 1996, P HIGH PERF COMP NET, V1067, P183
[5]   A simple scoring ratio to index the conformity of radiosurgical treatment plans - Technical note [J].
Paddick, I .
JOURNAL OF NEUROSURGERY, 2000, 93 :219-222
[6]   THE SHEFFIELD STEREOTAXIC RADIOSURGERY UNIT - PHYSICAL CHARACTERISTICS AND PRINCIPLES OF OPERATION [J].
WALTON, L ;
BOMFORD, CK ;
RAMSDEN, D .
BRITISH JOURNAL OF RADIOLOGY, 1987, 60 (717) :897-906
[7]   PHYSICS OF GAMMA-KNIFE APPROACH ON CONVERGENT BEAMS IN STEREOTAXIC RADIOSURGERY [J].
WU, A ;
LINDNER, G ;
MAITZ, AH ;
KALEND, AM ;
LUNSFORD, LD ;
FLICKINGER, JC ;
BLOOMER, WD .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1990, 18 (04) :941-949