Calibration transfer from sample cell to fiber-optic probe

被引:27
|
作者
Chen, CS
Brown, CW
Lo, SC
机构
[1] UNIV RHODE ISL,DEPT CHEM,KINGSTON,RI 02881
[2] US TOBACCO CO,DEPT RES & DEV,NASHVILLE,TN 37203
关键词
multivariate calibration; multicomponent analysis; calibration transfer; Fourier transform;
D O I
10.1366/0003702971940927
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A calibration transfer method, piecewise direct standardization (PDS), was applied to a set of two-component samples measured on the same UV-visible spectrometer with the use of a cuvette cell with a 10-mm pathlength and a fiber-optic probe with a 2-mm pathlength, Piecewise direct standardization proceeds by determining a structured transformation matrix using the spectra of a few samples measured with both devices. This transformation matrix can then be used to transform any spectrum measured on one device to that obtained on another device, thereby making the calibration model transferable between devices. We used the spectra measured in a cuvette as the standard set and transferred the calibration model obtained for these spectra to spectra measured with a 2-mm fiber-optic probe on the same instrument. The total standard error of prediction (SEP) for the fiber-optic probe was 5.84 before the calibration transfer and 1.87 afterwards. Spectra were also processed by taking the Fourier transform prior to the calibration transfer, The 512 data points in each spectrum were compressed to 32 terms, starting with the first term after the dc offset. This processing reduced the background and the noise, As a consequence, in the Fourier domain, the total SEP was 5.69 before the calibration standardization and 0.79 after the calibration standardization. A calibration transfer was also performed between two fiber-optic probes; the total SEP in the spectral domain was 2.16 prior to the transfer and 1.04 after the transfer, whereas in the Fourier domain the SEP was 1.50 prior to the transfer and 0.77 after the transfer.
引用
收藏
页码:744 / 748
页数:5
相关论文
共 50 条
  • [1] Calibration transfer from sample cell to fiber-optic probe (vol 51, pg 744, 1997)
    Chen, CS
    Brown, CW
    Lo, SC
    APPLIED SPECTROSCOPY, 1998, 52 (03) : 476 - 476
  • [2] Fiber-optic radar calibration
    Puranen, M
    Karha, P
    Eskelinen, P
    IEEE AEROSPACE AND ELECTRONIC SYSTEMS MAGAZINE, 2005, 20 (09) : 30 - 33
  • [3] Automatic calibration of the actively stabilized fiber-optic time transfer
    Krehlik, P.
    Kolodziej, J.
    Sliwczynski, L.
    2018 EUROPEAN FREQUENCY AND TIME FORUM (EFTF), 2018, : 149 - 151
  • [4] Fiber-optic salinity probe
    Díaz-Herrera, N
    Esteban, O
    Navarrete, MC
    González-Cano, A
    SECOND EUROPEAN WORKSHOP ON OPTICAL FIBRE SENSORS: PROCEEDINGS, 2004, 5502 : 455 - 458
  • [5] Calibration of Multiplexed Fiber-Optic Spectroscopy
    Chen, Zeng-Ping
    Zhong, Li-Jing
    Nordon, Alison
    Littlejohn, David
    Holden, Megan
    Fazenda, Mariana
    Harvey, Linda
    McNeil, Brian
    Faulkner, Jim
    Morris, Julian
    ANALYTICAL CHEMISTRY, 2011, 83 (07) : 2655 - 2659
  • [6] NOVEL FIBER-OPTIC TEMPERATURE PROBE
    DAKIN, JP
    KAHN, DA
    OPTICAL AND QUANTUM ELECTRONICS, 1977, 9 (06) : 540 - 544
  • [7] Interferometric strain measurements with a fiber-optic probe
    Burnham-Fay, E. D.
    Jacobs-Perkins, D. W.
    Ellis, J. D.
    APPLIED ADVANCED OPTICAL METROLOGY SOLUTIONS, 2015, 9576
  • [8] Calibration of fiber-optic sensors using universal approximators
    Porada, E.
    Bock, W.J.
    Conference Record - IEEE Instrumentation and Measurement Technology Conference, 1994, 1 : 269 - 272
  • [9] Calibration of Reflectance-Based Fiber-Optic Hydrophones
    Howard, Samuel M.
    2016 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2016,
  • [10] Technical evaluation of a fiber-optic probe dissolution system
    Liu, Li
    Fitzgerald, Gifford
    Embry, Matthew
    Cantu, Ricardo
    Pack, Brian
    DISSOLUTION TECHNOLOGIES, 2008, 15 (01): : 10 - 20