Noninvasive pacemaker stress echocardiography for diagnosis of coronary artery disease - A multicenter study

被引:33
作者
Picano, E
Alaimo, A
Chubuchny, V
Plonska, E
Baldo, V
Baldini, U
Pauletti, M
Perticucci, R
Fonseca, L
Villarraga, HR
Emanuelli, C
Miracapillo, G
Hoffmann, E
De Nes, M
机构
[1] Inst Clin Physiol, I-56126 Pisa, Italy
[2] Grosseto Hosp, Cardiol Unit, Grosseto, Italy
[3] Fdn Valle del Lili Cali, Div Cardiol, Cali, Colombia
[4] Santa Luzia Hosp, Div Cardiol, Brasilia, DF, Brazil
[5] Arezzo Hosp, Div Cardiol, Arezzo, Italy
[6] Livorno Hosp, Div Cardiol, Livorno, Italy
[7] Div Cardiol, Cremona, Italy
[8] Div Cardiol, Rome, Italy
[9] Szecyn Hosp, Div Cardiol, Szecyn, Poland
[10] Ukranian Inst Cardiol, Kiev, Ukraine
[11] Palermo Hosp, Div Cardiol, Palermo, Italy
关键词
D O I
10.1016/S0735-1097(02)02157-5
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES We evaluated the feasibility, safety, and diagnostic accuracy of noninvasive pacemaker stress echocardiography (PASE) test as a potential alternative to exercise or pharmacologic stress in patients with suspected or known coronary artery disease (CAD). BACKGROUND Transesophageal atrial pacing echocardiography is an accurate test for detection of CAD, but its practical impact has been blunted by semi-invasiveness. In the expanding population of patients with permanent pacemakers (PMs), a pacing stress test can be administered noninvasively by external programming of the PM. METHODS In a prospective, multicenter, international study design, transthoracic stress-pacing echocardiography was performed in 46 consecutive patients with a permanent PM (33 men, 13 women; age 66.6 +/- 11.1 years) with suspected or known CAD. All patients underwent noninvasive PM-stress test by external programming (10 beats/min increments up to ischemia or target heart rate). Coronary angiography was performed in all patients independently of test results. Significant CAD was defined as greater than or equal to50% visually assessed diameter reduction in at least one major epicardial coronary artery. All coronary angiograms were scored by Duke prognostic weight values. RESULTS Fifteen patients were stimulated in atrial, and the remaining 31 in ventricular mode during stress. No significant side effects were observed. Echocardiographic images were interpretable in all patients. The average duration of stress was 8.9 +/- 3.5 min. Significant CAD was found in 27 patients. Sensitivity of PASE for identifying patients with significant CAD was 70%, specificity was 90%, and accuracy was 78%. When any abnormal wall motion at rest that remained unchanged at peak stress was regarded as a positive result of PASE, then the sensitivity, specificity, and accuracy levels for identifying patients with significant CAD were 85%, 84%, and 85%, respectively. Four of the eight patients with a false negative did not reach the target heart rate. The Duke values had significant correlation with values of wall motion score index at peak stress (r = 0.67) and with peak heart rate (r = -0.3). CONCLUSIONS Noninvasive PASE is a simple, rapid, safe, and diagnostically efficient option for patients with permanent PM and suspected or known CAD. (C) 2002 by the American College of Cardiology Foundation.
引用
收藏
页码:1305 / 1310
页数:6
相关论文
共 30 条
[1]   Stress echocardiography: Recommendations for performance and interpretation of stress echocardiography [J].
Armstrong, WF ;
Pellikka, PA ;
Ryan, T ;
Crouse, L ;
Zoghbi, WA .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 1998, 11 (01) :97-104
[2]   Pacing stress echocardiography: An alternative to pharmacologic stress testing [J].
Atar, S ;
Nagai, T ;
Cercek, B ;
Naqvi, TZ ;
Luo, H ;
Siegel, RJ .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 36 (06) :1935-1941
[3]  
BALDO V, 1997, CARDIOVASC IMAG, V8, P342
[4]   Detection of coronary stenoses by stress echocardiography using a previously implanted pacemaker for ventricular pacing: Preliminary report of a new method [J].
Benchimol, D ;
Mazanof, M ;
Dubroca, B ;
Benchimol, H ;
Bernard, V ;
Couffinhal, T ;
Dartigues, JF ;
Roudaut, R ;
Pillois, X ;
Bonnet, J .
CLINICAL CARDIOLOGY, 2000, 23 (11) :842-848
[5]   Survey of cardiac pacing and defibrillation in the United States in 1993 [J].
Bernstein, AD ;
Parsonnet, V .
AMERICAN JOURNAL OF CARDIOLOGY, 1996, 78 (02) :187-196
[6]  
CHAITMAN BR, 2001, HEART DIS TXB CARDIO, P129
[7]   STRESS ECHOCARDIOGRAPHY WITH TRANS-ESOPHAGEAL ATRIAL-PACING - PRELIMINARY-REPORT OF A NEW METHOD FOR DETECTION OF ISCHEMIC WALL MOTION ABNORMALITIES [J].
CHAPMAN, PD ;
DOYLE, TP ;
TROUP, PJ ;
GROSS, CM ;
WANN, LS .
CIRCULATION, 1984, 70 (03) :445-450
[8]  
Gibbons RJ, 1997, J AM COLL CARDIOL, V30, P260
[9]   VENTRICULAR SEPTAL MOTION AND LEFT-VENTRICULAR DIMENSIONS DURING ABNORMAL VENTRICULAR ACTIVATION [J].
GOMES, JAC ;
DAMATO, AN ;
AKHTAR, M ;
DHATT, MS ;
CALON, AH ;
REDDY, CP ;
MORAN, HE .
AMERICAN JOURNAL OF CARDIOLOGY, 1977, 39 (05) :641-650
[10]   Transmural metabolic heterogeneity at high cardiac work states [J].
Gong, G ;
Ugurbil, K ;
Zhang, JY .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 1999, 277 (01) :H236-H242