Anterior chamber angle measurement with optical coherence tomography:: Intraobserver and interobserver variability

被引:78
作者
Mueller, Maya
Dahmen, Gerlinde
Poerksen, Erk
Geerling, Gerd
Laqua, Horst
Ziegler, Andreas
Hoerauf, Hans
机构
[1] Univ Eye Clin, D-23538 Lubeck, Germany
[2] Inst Med Biometry & Stat, Lubeck, Germany
[3] Eye Clin, Kiel, Germany
[4] Univ Wurzburg, Eye Clin, Wurzburg, Germany
关键词
D O I
10.1016/j.jcrs.2006.07.014
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To assess intraobserver and interobserver variability of anterior segment optical coherence tomography (AS-OCT) as an objective diagnostic tool to quantify the anterior chamber angle and opening width. SETTING: University Eye Clinic, Lubeck, Germany. METHODS: The anterior chamber angle and opening width were assessed in 18 eyes of 9 healthy volunteers by 2 observers. Intraobserver reproducibility was evaluated by calculating an intraclass correlation coefficient (ICC) in a mixed model. Each observer had a separate model using information from 5 scans. Interobserver variability was determined by Bland-Altman analysis. The ICC was calculated in a mixed model using a residual maximum likelihood method. The results of 3 and 5 repeated scans were evaluated to indicate the change to 1 measurement application. RESULTS: The mean anterior chamber angle measurement was 35.9 degrees +/-5.7 (SD) for observer A and 36.2 +/- 5.7 degrees for observer B. The ICC was 0.94 and 0.91, respectively. The mean opening width was 315 +/- 62 mu m for observer A and 317 +/- 60 mu m for observer B. The ICC was 0.97 and 0.93, respectively. Interobserver comparisons showed a mean difference between anterior chamber angle measurements of -0.27 +/- 1.6 degrees, a limit of agreement (LOA) interval from -3.52 to 2.98 degrees, and an ICC estimate of 0.96. The mean difference in opening width measurements was 2.40 +/- 12.40 mu m, the LOA from -27.20 to 22.40 mu m, and the estimated ICC 0.96. Using I instead of the mean of 5 measurements, the LOA range increased by 3.46 degrees for the anterior chamber angle and 30.0 mu m for the opening width. CONCLUSION: Anterior chamber angle and opening width measurements by OCT showed low intraobserver and interobserver variability, indicating OCT is a valuable technique for quantitative assessment that provides reproducible measurements and objective documentation by different examiners.
引用
收藏
页码:1803 / 1808
页数:6
相关论文
共 34 条
  • [1] COMPARING METHODS OF MEASUREMENT - WHY PLOTTING DIFFERENCE AGAINST STANDARD METHOD IS MISLEADING
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1995, 346 (8982): : 1085 - 1087
  • [2] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [3] BOKER T, 1995, OPHTHALMIC RES, V27, P104
  • [4] BROWN H, 1999, APPL MIXED MODELS ME, P342
  • [5] FRANKE S, 1994, THESIS U HAMBURG
  • [6] Anterior chamber width measurement by high speed optical coherence tomography
    Goldsmith, JA
    Li, Y
    Chalita, MR
    Westphal, V
    Patil, CA
    Rollins, AM
    Izatt, JA
    Huang, D
    [J]. OPHTHALMOLOGY, 2005, 112 (02) : 238 - 244
  • [7] HANNEMANN P, 1996, THESIS U HAMBURG
  • [8] Hoerauf H, 2000, OPHTHALMIC SURG LAS, V31, P218
  • [9] Transscleral optical coherence tomography - An experimental study in ex-vivo human eyes
    Hoerauf, H
    Winkler, J
    Scholz, C
    Wirbelauer, C
    Gordes, RS
    Koch, P
    Engelhardt, R
    Laqua, H
    Birngruber, R
    [J]. LASERS IN SURGERY AND MEDICINE, 2002, 30 (03) : 209 - 215
  • [10] Hoerauf H, 2002, ARCH OPHTHALMOL-CHIC, V120, P816