Use of Absorbable Fibrin Sealant Patch (Tachosil) for Hemostasis in the Split Liver Transplantation

被引:0
|
作者
Vicentine, Fernando [1 ]
Perdigao, Fabiano [1 ]
Brustia, Raffaele [1 ]
Goumard, Claire [1 ]
Sepulveda, Ailton [1 ]
Schielke, Astrid [1 ]
Soubrane, Olivier [1 ,2 ]
Scatton, Olivier [1 ,2 ]
机构
[1] St Antoine Hosp, AP HP, Dept Hepatobiliary Surg & Liver Transplant, F-75571 Paris, France
[2] Univ Paris 06, Paris, France
关键词
D O I
暂无
中图分类号
R392 [医学免疫学]; Q939.91 [免疫学];
学科分类号
100102 ;
摘要
P-196
引用
收藏
页码:190 / 190
页数:1
相关论文
共 50 条
  • [21] The use of fibrin sealant as a hemostatic plug for liver biopsy tracts
    Falstrom, JK
    Goodman, NC
    Moore, MM
    Caldwell, SH
    Abbott, RD
    Spotnitz, WD
    THROMBOSIS AND HAEMOSTASIS, 1997, : OC796 - OC796
  • [22] The Use of TachoSil in Children Undergoing Liver Resection With or Without Segmental Liver Transplantation
    Mirza, D.
    Millar, A. J. W.
    Sharif, K.
    Vilca-Melendez, H.
    Rela, M.
    Heaton, N.
    EUROPEAN JOURNAL OF PEDIATRIC SURGERY, 2011, 21 (02) : 111 - 115
  • [23] NHS-POx-loaded patch versus fibrin sealant patch in a porcine robotic liver bleeding model
    Mathieu D’Hondt
    Edwin A. Roozen
    Frederiek Nuytens
    Johan Bender
    Alexandre Mottrie
    Kevin Bauwens
    Stuart J. Head
    BMC Surgery, 23
  • [24] NHS-POx-loaded patch versus fibrin sealant patch in a porcine robotic liver bleeding model
    D'Hondt, Mathieu
    Roozen, Edwin A.
    Nuytens, Frederiek
    Bender, Johan
    Mottrie, Alexandre
    Bauwens, Kevin
    Head, Stuart J.
    BMC SURGERY, 2023, 23 (01)
  • [25] Use of fibrin sealant as a hemostatic agent after liver biopsy in swine
    Paulson, EK
    Stephenson, GR
    Neal, MC
    Rossin, V
    Lawson, JH
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2000, 11 (07) : 905 - 911
  • [26] Fibrin Sealant Patch (TachoSil) vs Oxidized Regenerated Cellulose Patch (Surgicel Original) for the Secondary Treatment of Local Bleeding in Patients Undergoing Hepatic Resection: A Randomized Controlled Trial
    Genyk, Yuri
    Kato, Tomoaki
    Pomposelli, James J.
    Wright, J. Kelly, Jr.
    Sher, Linda S.
    Tetens, Vilhelm
    Chapman, William C.
    JOURNAL OF THE AMERICAN COLLEGE OF SURGEONS, 2016, 222 (03) : 261 - 268
  • [27] Use of tissue sealant patch (TachoSil) in the management of cerebrospinal fluid leaks after anterior cervical spine discectomy and fusion
    Gazzeri, Roberto
    Galarza, Marcelo
    Callovini, Giorgio
    BRITISH JOURNAL OF NEUROSURGERY, 2023, 37 (05) : 1406 - 1409
  • [28] Stump closure reinforcement with absorbable fibrin collagen sealant sponge (TachoSil) does not prevent pancreatic fistula after distal pancreatectomy: the FIABLE multicenter controlled randomized study
    Cunha, Antonio Sa
    Carrere, Nicolas
    Meunier, Bernard
    Fabre, Jean-Michel
    Sauvanet, Alain
    Pessaux, Patrick
    Ortega-Deballon, Pablo
    Fingerhut, Abe
    Lacaine, Francois
    AMERICAN JOURNAL OF SURGERY, 2015, 210 (04): : 739 - 748
  • [29] The Use of Fibrin Sealant, Cellulose Absorbable Hemostat, and Modified Studded Silicone Dumon Stent in the Management of Bronchopleural Fistula
    Patel, Dharmi
    Davoudi, Mohsen
    CHEST, 2015, 148 (04)
  • [30] Use of absorbable fibrin sealant patch to strengthen the gastrointestinal anastomosis performed on patients with peritoneal carcinomatosis treated with intention to cure by debulking surgery and intraoperative hyperthermic intraperitoneal chemotherapy
    Torres-Melero, Juan
    Jacob Motos-Mico, Jose
    Lorenzo-Linan, Miguel
    Morales-Gonzalez, Alvaro
    Rosado-Cobian, Rafael
    CIRUGIA Y CIRUJANOS, 2016, 84 (02): : 102 - 108