Determination of reference intervals for serum creatinine, creatinine excretion and creatinine clearance with an enzymatic and a modified Jaffe method

被引:198
|
作者
Junge, W
Wilke, B
Halabi, A
Klein, G
机构
[1] Friedrich Ebert Krankenhauses GmbH, Zent Lab, D-24534 Neumunster, Germany
[2] Lab Klin Forsch GmbH, Raisdorf, Germany
[3] Inst Klin Pharmakol GmbH, Kiel, Germany
[4] Roche Diagnost GmbH, Mannheim, Germany
关键词
creatinine clearance; reference intervals; Jaffe compensated; enzymatic PAP method;
D O I
10.1016/j.cccn.2004.02.007
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Objectives: The aim of this study was to determine the reference intervals for serum creatinine, the renal creatinine output and the creatinine clearance (CrCl) with two new methods for accurate creatinine determination. Methods: The reference population consisted of 252 healthy subjects (127 males and 125 females) at the age between 18 and 74 years, median 27. Urine was collected for exactly 24 h. Creatinine in serum and urine was measured with an enzymatic assay ("Creatinine Plus") and a modification of the kinetic Jaffe reaction, named "Jaffe compensated". Results: Reference values for serum creatinine were almost identical to previously published ones obtained with the same methods: 0.73-1.18 and 0.55-1.02 mg/dl for males and females, respectively, with the enzymatic, 0.72-1.16 and 0.55-0.96 mg/dl with the compensated Jaffe method (Jcomp). CrCl values were normally distributed and showed no gender difference in contrast to some previous studies. The reference interval for the entire group was found to be 66-143 ml/min with the enzymatic assay and 71-151 ml/min with the chemical one. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:137 / 148
页数:12
相关论文
共 50 条
  • [31] BIOLOGICAL VARIATION OF SERUM AND URINE CREATININE AND CREATININE CLEARANCE
    GUNN, IR
    ANNALS OF CLINICAL BIOCHEMISTRY, 1989, 26 : 302 - 302
  • [32] Comparison of Spot Creatinine Estimation by StatSensor Creatinine Meter and Serum Creatinine Estimation by Conventional Enzymatic Method
    Chandrasekar, Manoj
    Shetty, Manjunath Sanjeeva
    Hathur, Basavanagowdappa
    Vishwanath, Prashant
    Prashant, Akila
    Kulkarni, Praveen
    Kiran, K. K.
    Chandra, Naman
    Devaraju, Abhijith
    Begos, Dennis
    Oyelakin-Ogunbileje, John O.
    Murthy, Vishakantha
    JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2024, 35 (10):
  • [33] BILIRUBIN INTERFERENCE WITH KINETIC JAFFE METHOD FOR SERUM CREATININE
    DAUGHERTY, NA
    HAMMOND, KB
    OSBERG, IM
    CLINICAL CHEMISTRY, 1978, 24 (02) : 392 - 393
  • [34] COMBINED ENZYMIC-JAFFE METHOD FOR CREATININE IN SERUM
    YATZIDIS, H
    FRANGOSPLEMENOS, M
    KOUTSICOS, D
    CLINICAL CHEMISTRY, 1982, 28 (02) : 384 - 385
  • [35] LC-MS/MS Method for Serum Creatinine: Comparison with Enzymatic Method and Jaffe Method
    Ou, Meixian
    Song, Yunxiao
    Li, Shuijun
    Liu, Gangyi
    Jia, Jingying
    Zhang, Menqi
    Zhang, Haichen
    Yu, Chen
    PLOS ONE, 2015, 10 (07):
  • [36] MODIFIED DETERMINATION OF CREATININE IN SERUM AND URINE
    MILLERMANN, EG
    ACTA MEDICA ACADEMIAE SCIENTIARUM HUNGARICAE, 1974, 31 (3-4) : 281 - 281
  • [37] Method comparation of Backman coulter Jaffe and enzymatic creatinine methods
    Bartolovic, D.
    Stankovic, S.
    Bulic, M.
    CLINICA CHIMICA ACTA, 2024, 558
  • [38] Method evaluation of an enzymatic method for serum creatinine
    Saibaba K.S.S.
    Rao P.V.L.N.S.
    Murty K.V.D.
    Bhaskar M.V.
    Indian Journal of Clinical Biochemistry, 1997, 12 (2) : 139 - 141
  • [39] ON THE COLORIMETRIC DETERMINATION OF CREATININE BY THE JAFFE REACTION
    BONSNES, RW
    TAUSSKY, HH
    JOURNAL OF BIOLOGICAL CHEMISTRY, 1945, 158 (03) : 581 - 591
  • [40] REFERENCE VALUES OF UREA, CREATININE, AND CREATININE CLEARANCE IN CHILDREN AND ADOLESCENTS
    ARGUELLES, B
    BARJA, J
    SAEZ, MRH
    TAMAYO, G
    BRAVO, NG
    BAYLE, MS
    NEFROLOGIA, 1994, 14 (02): : 175 - 180