Biological variation data and analytical specification goal estimates of the thrombin generation assay with and without thrombomodulin in healthy individuals

被引:5
作者
Mairesse, Antoine [1 ]
Bayart, Jean-Louis [1 ]
Desmet, Sandrine [1 ]
Lopes Dos Santos, Helder [1 ]
Saussoy, Pascale [1 ]
Defour, Jean-Philippe [1 ]
Eeckhoudt, Stephane [1 ]
van Dievoet, Marie-Astrid [1 ]
机构
[1] Clin Univ St Luc, Dept Labs Clin, Brussels, Belgium
关键词
biological variation; calibrated automated thrombogram; platelet poor plasma; reference change value; thrombin generation assay; RECURRENT VENOUS THROMBOSIS; INCREASED RISK; CIRRHOSIS; NORMALIZATION; HEMOSTASIS; CAT;
D O I
10.1111/ijlh.13388
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Evaluation of an individual's thrombin-generating capacity enables a global assessment of the coagulation cascade and is therefore thought to better reflect the clotting function of blood. However, the lack of standardization still hampers the use in routine clinical practice. Methods Nineteen healthy subjects were sampled once a week for 5 consecutive weeks. Thrombin generation assay (TGA) was performed in duplicate by calibrated automated thrombogram (CAT) on platelet poor plasma with and without thrombomodulin. After exclusion of outliers, a nested analysis of variance (ANOVA) was performed to evaluate the biological variability (BV) results. Analytical variation (CVA), within-individual variation (CVI), between-individual variation (CVG), index of individuality (II), and reference change value (RCV) were calculated. Results All parameters taken together, the CVA, CVI, and CVG without TM, ranged from 2.8% to 6.5%, from 4.1% to 13.3% and from 10.4% to 28.4%, respectively. For TG with TM, CVI and CVG were higher and ranged from 5.0% to 18.1% and from 14.9% to 35.3%, respectively. For endogenous thrombin potential (ETP), a CVI of 4.1% and CVG of 10.4% were obtained without addition of thrombomodulin (TM). With addition of TM, both CVI and CVG were higher: 14.0% and 34.8%, respectively. The II was low and the RCV ranged from 17.2% to 50.4%. Conclusion CAT parameters are highly individualized and population-based reference values could be called into question. The assessment of BV and RCV for thrombin generation assays could optimize interpretation of serial patient results and guide setting of analytical specification goals.
引用
收藏
页码:450 / 457
页数:8
相关论文
共 36 条
  • [1] Aarsand AKF-CP, EFLM BIOL VARIATTION
  • [2] Biological Variation in Tests of Hemostasis (vol 34, pg 635, 2008)
    Banfi, Giuseppe
    Del Fabbro, Massimo
    [J]. SEMINARS IN THROMBOSIS AND HEMOSTASIS, 2009, 35 (01) : 119 - 126
  • [3] High rate of unprovoked recurrent venous thrombosis is associated with high thrombin-generating potential in a prospective cohort study
    Besser, M.
    Baglin, C.
    Luddington, R.
    Vlieg, A. van Hylckama
    Baglin, T.
    [J]. JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2008, 6 (10) : 1720 - 1725
  • [4] Generation of data on within-subject biological variation in laboratory medicine: An update
    Braga, Federica
    Panteghini, Mauro
    [J]. CRITICAL REVIEWS IN CLINICAL LABORATORY SCIENCES, 2016, 53 (05) : 313 - 325
  • [5] Thrombin generation measurement using the ST Genesia Thrombin Generation System in a cohort of healthy adults: Normal values and variability
    Calzavarini, Sara
    Brodard, Justine
    Quarroz, Claudia
    Maire, Livia
    Nuetzi, Raphael
    Jankovic, Jovana
    Rotondo, Laura C.
    Giabbani, Evelyne
    Fiedler, Georg Martin
    Nagler, Michael
    Angelillo-Scherrer, Anne
    [J]. RESEARCH AND PRACTICE IN THROMBOSIS AND HAEMOSTASIS, 2019, 3 (04) : 758 - 768
  • [6] Measuring thrombin generation as a tool for predicting hemostatic potential and transfusion requirements following trauma
    Cardenas, Jessica C.
    Rahbar, Elaheh
    Pommerening, Matthew J.
    Baer, Lisa A.
    Matijevic, Nena
    Cotton, Bryan A.
    Holcomb, John B.
    Wade, Charles E.
    [J]. JOURNAL OF TRAUMA AND ACUTE CARE SURGERY, 2014, 77 (06) : 839 - 845
  • [7] Sample collections from healthy volunteers for biological variation estimates' update: a new project undertaken by the Working Group on Biological Variation established by the European Federation of Clinical Chemistry and Laboratory Medicine
    Carobene, Anna
    Strollo, Marta
    Jonker, Niels
    Barla, Gerhard
    Bartlett, William A.
    Sandberg, Sverre
    Sylte, Marit Sverresdotter
    Roraas, Thomas
    Solvik, Una Orvim
    Fernandez-Calle, Pilar
    Diaz-Garzon, Jorge
    Tosato, Francesca
    Plebani, Mario
    Coskun, Abdurrahman
    Serteser, Mustafa
    Unsal, Ibrahim
    Ceriotti, Ferruccio
    [J]. CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2016, 54 (10) : 1599 - 1608
  • [8] The distribution of the largest of a set of estimated variances as a fraction of their total
    Cochran, WG
    [J]. ANNALS OF EUGENICS, 1941, 11 : 47 - 52
  • [9] Evaluation of thrombin generating capacity in plasma from patients with haemophilia A and B
    Dargaud, Y
    Béguin, S
    Lienhart, A
    Al Dieri, R
    Trzeciak, C
    Bordet, JC
    Hemker, HC
    Negrier, C
    [J]. THROMBOSIS AND HAEMOSTASIS, 2005, 93 (03) : 475 - 480
  • [10] Standardisation of thrombin generation test - which reference plasma for TGT?: An international multicentre study
    Dargaud, Y.
    Luddington, R.
    Gray, E.
    Lecompte, T.
    Siegemund, T.
    Baglin, T.
    Hogwood, J.
    Regnault, V.
    Siegemund, A.
    Negrier, C.
    [J]. THROMBOSIS RESEARCH, 2010, 125 (04) : 353 - 356