Detection and quantification of plasma amyloid-β by selected reaction monitoring mass spectrometry

被引:30
|
作者
Kim, Jun Seok [1 ]
Ahn, Hee-Sung [1 ,2 ]
Cho, Soo Min [3 ]
Lee, Ji Eun [1 ]
Kim, YoungSoo [3 ]
Lee, Cheolju [1 ,2 ]
机构
[1] Korea Inst Sci & Technol, Ctr Theragnosis, Seoul 136791, South Korea
[2] Univ Sci & Technol, Dept Biol Chem, Taejon 305333, South Korea
[3] Korea Inst Sci & Technol, Ctr Neuromed, Seoul 136791, South Korea
关键词
Alzheimer's disease; Amyloid-beta; Selected reaction monitoring; High pH reversed-phase liquid chromatography; Surrogate peptide; Plasma; ALZHEIMERS-DISEASE PATIENTS; CEREBROSPINAL-FLUID; PEPTIDES; PROTEIN; QUANTITATION; CHROMATOGRAPHY; IDENTIFICATION; BIOMARKERS; A-BETA-42; ASSAYS;
D O I
10.1016/j.aca.2014.06.024
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Amyloid-beta (A beta) in human plasma was detected and quantified by an antibody-free method, selected reaction monitoring mass spectrometry (SRM-MS) in the current study. Due to its low abundance, SRM-based quantification in 10 mu L plasma was a challenge. Prior to SRM analysis, human plasma proteins as a whole were digested by trypsin and high pH reversed-phase liquid chromatography (RPLC) was used to fractionate the tryptic digests and to collect peptides, A beta(1-5), A beta(6-16), A beta(17-28) and A beta(29-40(42)) of either A beta(1-40) or A beta(1-42). Among those peptides, A beta(17-28) was selected as a surrogate to measure the total A beta level. Human plasma samples obtained from triplicate sample preparations were analyzed, obtaining 4.20 ng mL(-1) with a CV of 25.3%. Triplicate measurements for each sample preparation showed CV of <5%. Limit of quantification was obtained as 132 pM, which corresponded to 570 pg mL(-1) of A beta(1-40). Until now, most quantitative measurements of A beta in plasma or cerebrospinal fluid have required antibody-based immunoassays. Since quantification of A beta by immunoassays is highly dependent on the extent of epitope exposure due to aggregation or plasma protein binding, it is difficult to accurately measure the actual concentration of A beta in plasma. Our diagnostic method based on SRM using a surrogate peptide of A beta is promising in that actual amounts of total A beta can be measured regardless of the conformational status of the biomarker. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:1 / 9
页数:9
相关论文
共 50 条
  • [31] Targeted proteome investigation via selected reaction monitoring mass spectrometry
    Maiolica, Alessio
    Juenger, Martin A.
    Ezkurdia, Iakes
    Aebersold, Ruedi
    JOURNAL OF PROTEOMICS, 2012, 75 (12) : 3495 - 3513
  • [32] Constrained selected reaction monitoring: Quantification of selected post-translational modifications and protein isoforms
    Liu, Xiaoqian
    Jin, Zhicheng
    O'Brien, Richard
    Bathon, Joan
    Dietz, Harry C.
    Grote, Eric
    Van Eyk, Jennifer E.
    METHODS, 2013, 61 (03) : 304 - 312
  • [33] Variance component analysis to assess protein quantification in biomarker validation: application to selected reaction monitoring-mass spectrometry
    Klich, Amna
    Mercier, Catherine
    Gerfault, Laurent
    Grangeat, Pierre
    Beaulieu, Corinne
    Degout-Charmette, Elodie
    Fortin, Tanguy
    Mahe, Pierre
    Giovannelli, Jean-Francois
    Charrier, Jean-Philippe
    Giremus, Audrey
    Maucort-Boulch, Delphine
    Roy, Pascal
    BMC BIOINFORMATICS, 2018, 19
  • [34] Identification and quantification of amyloid beta-related peptides in human plasma using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry
    Kaneko, Naoki
    Yamamoto, Rie
    Sato, Taka-Aki
    Tanaka, Koichi
    PROCEEDINGS OF THE JAPAN ACADEMY SERIES B-PHYSICAL AND BIOLOGICAL SCIENCES, 2014, 90 (03): : 104 - 117
  • [35] Parallel Reaction Monitoring: A Targeted Experiment Performed Using High Resolution and High Mass Accuracy Mass Spectrometry
    Rauniyar, Navin
    INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2015, 16 (12): : 28566 - 28581
  • [36] Effect of Collision Energy Optimization on the Measurement of Peptides by Selected Reaction Monitoring (SRM) Mass Spectrometry
    MacLean, Brendan
    Tomazela, Daniela M.
    Abbatiello, Susan E.
    Zhang, Shucha
    Whiteaker, Jeffrey R.
    Paulovich, Amanda G.
    Carr, Steven A.
    MacCoss, Michael J.
    ANALYTICAL CHEMISTRY, 2010, 82 (24) : 10116 - 10124
  • [37] A lectin-coupled, multiple reaction monitoring based quantitative analysis of human plasma glycoproteins by mass spectrometry
    Ahn, Yeong Hee
    Shin, Park Min
    Ji, Eun Sun
    Kim, Hoguen
    Yoo, Jong Shin
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2012, 402 (06) : 2101 - 2112
  • [38] Gold nanoparticles assisted sensitivity improvement of interdigitated microelectrodes biosensor for amyloid-β detection in plasma sample
    Yoo, Yong Kyoung
    Kim, Gangeun
    Park, Dongsung
    Kim, Jinsik
    Kim, YoungSoo
    Kim, Hye Yun
    Yang, Seung Hoon
    Lee, Jeong Hoon
    Hwang, Kyo Seon
    SENSORS AND ACTUATORS B-CHEMICAL, 2020, 308
  • [39] Dual mass spectrometry as a tool to improve annotation and quantification in targeted plasma lipidomics
    Gao, Liang
    Cazenave-Gassiot, Amaury
    Burla, Bo
    Wenk, Markus R.
    Torta, Federico
    METABOLOMICS, 2020, 16 (05)
  • [40] Quantification of the trans-synaptic partners neurexin- neuroligin in CSF of neurodegenerative diseases by parallel reaction monitoring mass spectrometry
    Camporesi, Elena
    Nilsson, Johanna
    Vrillon, Agathe
    Cognat, Emmanuel
    Hourregue, Claire
    Zetterberg, Henrik
    Blennow, Kaj
    Becker, Bruno
    Brinkmalm, Ann
    Paquet, Claire
    Brinkmalm, Gunnar
    EBIOMEDICINE, 2022, 75