Detection and quantification of plasma amyloid-β by selected reaction monitoring mass spectrometry

被引:30
|
作者
Kim, Jun Seok [1 ]
Ahn, Hee-Sung [1 ,2 ]
Cho, Soo Min [3 ]
Lee, Ji Eun [1 ]
Kim, YoungSoo [3 ]
Lee, Cheolju [1 ,2 ]
机构
[1] Korea Inst Sci & Technol, Ctr Theragnosis, Seoul 136791, South Korea
[2] Univ Sci & Technol, Dept Biol Chem, Taejon 305333, South Korea
[3] Korea Inst Sci & Technol, Ctr Neuromed, Seoul 136791, South Korea
关键词
Alzheimer's disease; Amyloid-beta; Selected reaction monitoring; High pH reversed-phase liquid chromatography; Surrogate peptide; Plasma; ALZHEIMERS-DISEASE PATIENTS; CEREBROSPINAL-FLUID; PEPTIDES; PROTEIN; QUANTITATION; CHROMATOGRAPHY; IDENTIFICATION; BIOMARKERS; A-BETA-42; ASSAYS;
D O I
10.1016/j.aca.2014.06.024
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Amyloid-beta (A beta) in human plasma was detected and quantified by an antibody-free method, selected reaction monitoring mass spectrometry (SRM-MS) in the current study. Due to its low abundance, SRM-based quantification in 10 mu L plasma was a challenge. Prior to SRM analysis, human plasma proteins as a whole were digested by trypsin and high pH reversed-phase liquid chromatography (RPLC) was used to fractionate the tryptic digests and to collect peptides, A beta(1-5), A beta(6-16), A beta(17-28) and A beta(29-40(42)) of either A beta(1-40) or A beta(1-42). Among those peptides, A beta(17-28) was selected as a surrogate to measure the total A beta level. Human plasma samples obtained from triplicate sample preparations were analyzed, obtaining 4.20 ng mL(-1) with a CV of 25.3%. Triplicate measurements for each sample preparation showed CV of <5%. Limit of quantification was obtained as 132 pM, which corresponded to 570 pg mL(-1) of A beta(1-40). Until now, most quantitative measurements of A beta in plasma or cerebrospinal fluid have required antibody-based immunoassays. Since quantification of A beta by immunoassays is highly dependent on the extent of epitope exposure due to aggregation or plasma protein binding, it is difficult to accurately measure the actual concentration of A beta in plasma. Our diagnostic method based on SRM using a surrogate peptide of A beta is promising in that actual amounts of total A beta can be measured regardless of the conformational status of the biomarker. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:1 / 9
页数:9
相关论文
共 50 条
  • [21] Protein Quantification by MALDI-Selected Reaction Monitoring Mass Spectrometry Using Sulfonate Derivatized Peptides
    Lesur, Antoine
    Varesio, Emmanuel
    Hopfgartner, Gerard
    ANALYTICAL CHEMISTRY, 2010, 82 (12) : 5227 - 5237
  • [22] Distinct deposition of amyloid-β species in brains with Alzheimer's disease pathology visualized with MALDI imaging mass spectrometry
    Kakuda, Nobuto
    Miyasaka, Tomohiro
    Iwasaki, Noriyuki
    Nirasawa, Takashi
    Wada-Kakuda, Satoko
    Takahashi-Fujigasaki, Junko
    Murayama, Shigeo
    Ihara, Yasuo
    Ikegawa, Masaya
    ACTA NEUROPATHOLOGICA COMMUNICATIONS, 2017, 5 : 73
  • [23] Range of protein detection by selected/multiple reaction monitoring mass spectrometry in an unfractionated human cell culture lysate
    Ebhardt, H. Alexander
    Sabido, Eduard
    Huettenhain, Ruth
    Collins, Ben
    Aebersold, Ruedi
    PROTEOMICS, 2012, 12 (08) : 1185 - 1193
  • [24] Automated Selected Reaction Monitoring Software for Accurate Label-Free Protein Quantification
    Teleman, Johan
    Karlsson, Christofer
    Waldemarson, Sofia
    Hansson, Karin
    James, Peter
    Malmstrom, Johan
    Levander, Fredrik
    JOURNAL OF PROTEOME RESEARCH, 2012, 11 (07) : 3766 - 3773
  • [25] Amyloid-β-neuropeptide interactions assessed by ion mobility-mass spectrometry
    Soper, Molly T.
    DeToma, Alaina S.
    Hyung, Suk-Joon
    Lim, Mi Hee
    Ruotolo, Brandon T.
    PHYSICAL CHEMISTRY CHEMICAL PHYSICS, 2013, 15 (23) : 8952 - 8961
  • [26] 18O-Labeled Proteome Reference as Global Internal Standards for Targeted Quantification by Selected Reaction Monitoring-Mass Spectrometry
    Kim, Jong-Seo
    Fillmore, Thomas L.
    Liu, Tao
    Robinson, Errol
    Hossain, Mahmud
    Champion, Boyd L.
    Moore, Ronald J.
    Camp, David G., II
    Smith, Richard D.
    Qian, Wei-Jun
    MOLECULAR & CELLULAR PROTEOMICS, 2011, 10 (12)
  • [27] Estimation of Absolute Protein Quantities of Unlabeled Samples by Selected Reaction Monitoring Mass Spectrometry
    Ludwig, Christina
    Claassen, Manfred
    Schmidt, Alexander
    Aebersold, Ruedi
    MOLECULAR & CELLULAR PROTEOMICS, 2012, 11 (03)
  • [28] Towards clinical applications of selected reaction monitoring for plasma protein biomarker studies
    Krisp, Christoph
    Randall, Sarah A.
    McKay, Matthew J.
    Molloy, Mark P.
    PROTEOMICS CLINICAL APPLICATIONS, 2012, 6 (1-2) : 42 - 59
  • [29] Evaluation of meter-long monolithic columns for selected reaction monitoring mass spectrometry
    Ohtani, Yuta
    Aburaya, Shunsuke
    Minakuchi, Hiroyoshi
    Miura, Natsuko
    Aoki, Wataru
    Ueda, Mitsuyoshi
    JOURNAL OF BIOSCIENCE AND BIOENGINEERING, 2019, 128 (03) : 379 - 383
  • [30] Quantification of ghrelin and des-acyl ghrelin in human plasma by using cubic-selected reaction-monitoring LC-MS