Facade and rooftop PV installation strategy for building integrated photo voltaic application

被引:28
作者
Atmaja, Tinton Dwi [1 ]
机构
[1] Indonesian Inst Sci, Res Ctr Elect Power & Mechatron, Bandung 40135, Indonesia
来源
INTERNATIONAL CONFERENCE ON SUSTAINABLE ENERGY ENGINEERING AND APPLICATION (ICSEEA) 2012 | 2013年 / 32卷
关键词
Building integrated photo voltaic; installation; facade; rooftop; inclination; direction; review; CONNECTED PHOTOVOLTAIC SYSTEMS; PERFORMANCE; BRAZIL; AREAS; BIPV;
D O I
10.1016/j.egypro.2013.05.014
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Building integrated photo voltaic (BIPV) is an emerged research topic to optimize building component replacement using certain types of photo voltaic (PV) module. This paper conducts a strategic review on the optimum PV module installation to generate electricity from the building envelope. The facades and rooftops would be an object of building envelope to be deposited with a specific characteristic installation of PV module. Facade installation will be affected by the geographical position of the site, so a certain directions shall perform a higher electric energy production than the other directions. Recent calculations of the inclination angle of attaching the PV module in the selected walls indicates that an optimum angle in horizontal and vertical inclination. The calculation also uses installation distance to module length ratio to achieve a greater solar insulation on the PV modules. Rooftop installation will consider the curved rooftop as a potential feeder either it was bonded or mounted. It is believed that overall performance of curved PV installation could outperform flat PV installation in certain time. Other calculation also performed to observe effective load carrying capacity (ELCC) against PV penetration level to perceive the optimum PV penetration level for high ELCC without resulting operational problems. (C) 2013 The Authors. Published by Elsevier Ltd.
引用
收藏
页码:105 / 114
页数:10
相关论文
共 20 条
[1]  
Ayyash S, 1983, ENERGY RES, V7, P279
[2]   Inverter sizing of grid-connected photovoltaic systems in the light of local solar resource distribution characteristics and temperature [J].
Burger, B ;
Rüther, R .
SOLAR ENERGY, 2006, 80 (01) :32-45
[3]  
Faaborg A., 2002, IEAPVPST5102002
[4]   EFFECTIVE LOAD CARRYING CAPABILITY OF GENERATING UNITS [J].
GARVER, LL .
IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1966, PA85 (08) :910-&
[5]   Solar cooling for small office buildings: Comparison of solar thermal and photovoltaic options for two different European climates [J].
Hartmann, N. ;
Glueck, C. ;
Schmidt, F. P. .
RENEWABLE ENERGY, 2011, 36 (05) :1329-1338
[6]  
Henning H-M, 2007, SOLARE KUHLUNG KLIMA, P21
[7]   Optimization of the building integrated photovoltaic system in office buildings-Focus on the orientation, inclined angle and installed area [J].
Hwang, Taeyon ;
Kang, Seokyoun ;
Kim, Jeong Tai .
ENERGY AND BUILDINGS, 2012, 46 :92-104
[8]   The strategic siting and the roofing area requirements of building-integrated photovoltaic solar energy generators, in urban areas in Brazil [J].
Jardim, Carolina da Silva ;
Ruther, Ricardo ;
Salamoni, Isabel Tourinho ;
Viana, Trajano de Souza ;
Rebechi, Samuel Hilario ;
Knob, Paulo Jose .
ENERGY AND BUILDINGS, 2008, 40 (03) :365-370
[9]   A MODEL FOR CAPACITY CREDIT EVALUATION OF GRID-CONNECTED PHOTOVOLTAIC SYSTEMS WITH FUEL-CELL SUPPORT [J].
KHALLAT, MA ;
RAHMAN, S .
IEEE TRANSACTIONS ON POWER SYSTEMS, 1988, 3 (03) :1270-1276
[10]   Techno-economic simulation and optimization of residential grid-connected PV system for the Queensland climate [J].
Liu, Gang ;
Rasul, M. G. ;
Amanullah, M. T. O. ;
Khan, M. M. K. .
RENEWABLE ENERGY, 2012, 45 :146-155