Low-dose CT in body-packers: delineation of body packs and radiation dose in a porcine model

被引:4
|
作者
Scherr, Michael K. [1 ]
Peschel, Oliver [2 ]
Grimm, Jochen M. [1 ]
Ziegeler, Edvard [1 ]
Uhl, Michael [3 ]
Geyer, Lucas L. [1 ]
Reiser, Maximilian F. [1 ]
Wirth, Stefan [1 ]
机构
[1] Univ Munich, Dept Clin Radiol, D-80336 Munich, Germany
[2] Univ Munich, Inst Forens Med, D-80336 Munich, Germany
[3] Bavarian State Criminal Police Off, Dept Chem, D-80636 Munich, Germany
关键词
Delineation of drug packages; Low-dose computed tomography; Illicit drugs; Body packing; Dose reduction; CT window settings; COMPUTED-TOMOGRAPHY; ILLICIT DRUGS; RADIOGRAPHY; PUSHERS; COCAINE; PROTOCOLS; STUFFERS; PRODUCT;
D O I
10.1007/s12024-013-9522-7
中图分类号
DF [法律]; D9 [法律]; R [医药、卫生];
学科分类号
0301 ; 10 ;
摘要
Purpose To compare low-dose computed tomography (CT) with standard CT and conventional radiography (CR) regarding delineation of body packs and radiation dose. Methods Nine samples of illicit drugs including cocaine, heroin, and hashish were positioned in the rectum of a 121.5 kg pig cadaver. Each sample was scanned on a 64-row MDCT with 120 kV: one standard modulated pelvic protocol (STD), and without modulation at 80 mA (LD80), 30 mA (LD30), and 10 mA (LD10). Additionally, conventional abdominal anterior-posterior radiographs (77 kV and 106 +/- 13 mA) were taken. Body pack characteristics (wrapping, content, shape) were rated independently by two radiologists and summarized to a delineation score from 0 to 9 with scores >= 6 representing sufficient delineation. Mean delineation scores were calculated for CR and CT protocols. These were additionally differentiated for readings in soft tissue (S), lung (L), user defined, variable window settings (V), and in cumulative window evaluation including all the other window settings (SLV). Effective doses were calculated (mSv). Results The CR delineation score was insufficient (3.1 +/- 2.5; 2.4 +/- 0.3 mSv). For CT, the SLV window setting performed best (p<0.01). Its score significantly (p<0.01) declined with decreasing effective radiation doses: STD (8.8 +/- 0.5; 10.6 mSv), LD80 (8.2 +/- 0.7; 2.6 mSv), LD30 (6.8 +/- 1.3; 1.0 mSv), and LD10 (4.6 +/- 1.9; 0.3 mSv). Thus, LD30 was the protocol using the lowest but sufficient dose. Moreover, for LD30 further differentiation between the particular window settings resulted in scores of 6.4 +/- 1.3 (L), 6.3 +/- 1.2 (V), and 3.1 +/- 1.0 (S). Conclusions With appropriate window settings, low-dose CT at 30 mA allowed for sufficient body-pack delineation below the dose of CR, which itself performed insufficient.
引用
收藏
页码:170 / 178
页数:9
相关论文
共 50 条
  • [41] Tumor load in patients with multiple myeloma: β;-microglobulin levels versus low-dose whole-body CT
    Pfahler, Vanessa
    D'Anastasi, Melvin
    Duerr, Hans-Roland
    Schinner, Regina
    Ricke, Jens
    Baur-Melnyk, Andrea
    EUROPEAN JOURNAL OF HAEMATOLOGY, 2020, 104 (05) : 383 - 389
  • [42] Iterative Reconstruction Technique for Reducing Body Radiation Dose at CT: Feasibility Study
    Hara, Amy K.
    Paden, Robert G.
    Silva, Alvin C.
    Kujak, Jennifer L.
    Lawder, Holly J.
    Pavlicek, William
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 193 (03) : 764 - 771
  • [43] Non-osseous incidental findings in low-dose whole-body CT in patients with multiple myeloma
    Surov, A.
    Bach, A. G.
    Tcherkes, A.
    Schramm, D.
    BRITISH JOURNAL OF RADIOLOGY, 2014, 87 (1041)
  • [44] Are low-dose CT scans a satisfactory substitute for stereoradiographs for migration studies? A preclinical test of low-dose CT scanning protocols and their application in a pilot patient
    Eriksson, Thomas
    Maguire, Gerald Q., Jr.
    Noz, Marilyn E.
    Zeleznik, Michael P.
    Olivecrona, Henrik
    Shalabi, Adel
    Hanni, Mari
    ACTA RADIOLOGICA, 2019, 60 (12) : 1643 - 1652
  • [45] Lateral Topography for Reducing Effective Dose in Low-Dose Chest CT
    Bang, Dong-Ho
    Lim, Daekeon
    Hwang, Wi-Sub
    Park, Seong-Hoon
    Jeong, Ok-man
    Kang, Kyung Wook
    Kang, Hohyung
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2013, 200 (06) : 1294 - 1297
  • [46] Whole-Body Low-Dose CT in Multiple Myeloma: Diagnostic Value of Appendicular Medullary Patterns of Attenuation
    Koutoulidis, Vassilis
    Terpos, Evangelos
    Klapa, Ioanna
    Cheliotis, George
    Ntanasis-Stathopoulos, Ioannis
    Boultadaki, Andriani
    Gavriatopoulou, Maria
    Kastritis, Efstathios
    Dimopoulos, Meletios A.
    Moulopoulos, Lia A.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2021, 216 (03) : 742 - 751
  • [47] Preoperative CT-guided localization of pulmonary nodules with low-dose radiation
    Ma, Yanhe
    Cheng, Shizhao
    Li, Jianhui
    Yuan, Wei
    Song, Zhenchun
    Zhang, Hong
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2023, 13 (07) : 4295 - 4304
  • [48] A Novel Total Variation Model for Low-Dose CT Image Denoising
    Chen, Wenbin
    Shao, Yanling
    Wang, Yanling
    Zhang, Quan
    Liu, Yi
    Yao, Linhong
    Chen, Yan
    Yang, Guanru
    Gui, Zhiguo
    IEEE ACCESS, 2018, 6 : 78892 - 78903
  • [49] Low-Dose Chest CT Protocols for Imaging COVID-19 Pneumonia: Technique Parameters and Radiation Dose
    Suliman, Ibrahim I.
    Khouqeer, Ghada A.
    Ahmed, Nada A.
    Abuzaid, Mohamed M.
    Sulieman, Abdelmoneim
    LIFE-BASEL, 2023, 13 (04):
  • [50] Separation-based model for low-dose CT image denoising
    Chen, Wenbin
    Bai, Junjie
    Gu, Xiaohua
    Li, Yuyan
    Shao, Yanling
    Zhang, Quan
    Liu, Yi
    Liu, Yanli
    Gui, Zhiguo
    JOURNAL OF ENGINEERING-JOE, 2020, 2020 (12): : 1198 - 1208