Low-dose CT in body-packers: delineation of body packs and radiation dose in a porcine model

被引:4
|
作者
Scherr, Michael K. [1 ]
Peschel, Oliver [2 ]
Grimm, Jochen M. [1 ]
Ziegeler, Edvard [1 ]
Uhl, Michael [3 ]
Geyer, Lucas L. [1 ]
Reiser, Maximilian F. [1 ]
Wirth, Stefan [1 ]
机构
[1] Univ Munich, Dept Clin Radiol, D-80336 Munich, Germany
[2] Univ Munich, Inst Forens Med, D-80336 Munich, Germany
[3] Bavarian State Criminal Police Off, Dept Chem, D-80636 Munich, Germany
关键词
Delineation of drug packages; Low-dose computed tomography; Illicit drugs; Body packing; Dose reduction; CT window settings; COMPUTED-TOMOGRAPHY; ILLICIT DRUGS; RADIOGRAPHY; PUSHERS; COCAINE; PROTOCOLS; STUFFERS; PRODUCT;
D O I
10.1007/s12024-013-9522-7
中图分类号
DF [法律]; D9 [法律]; R [医药、卫生];
学科分类号
0301 ; 10 ;
摘要
Purpose To compare low-dose computed tomography (CT) with standard CT and conventional radiography (CR) regarding delineation of body packs and radiation dose. Methods Nine samples of illicit drugs including cocaine, heroin, and hashish were positioned in the rectum of a 121.5 kg pig cadaver. Each sample was scanned on a 64-row MDCT with 120 kV: one standard modulated pelvic protocol (STD), and without modulation at 80 mA (LD80), 30 mA (LD30), and 10 mA (LD10). Additionally, conventional abdominal anterior-posterior radiographs (77 kV and 106 +/- 13 mA) were taken. Body pack characteristics (wrapping, content, shape) were rated independently by two radiologists and summarized to a delineation score from 0 to 9 with scores >= 6 representing sufficient delineation. Mean delineation scores were calculated for CR and CT protocols. These were additionally differentiated for readings in soft tissue (S), lung (L), user defined, variable window settings (V), and in cumulative window evaluation including all the other window settings (SLV). Effective doses were calculated (mSv). Results The CR delineation score was insufficient (3.1 +/- 2.5; 2.4 +/- 0.3 mSv). For CT, the SLV window setting performed best (p<0.01). Its score significantly (p<0.01) declined with decreasing effective radiation doses: STD (8.8 +/- 0.5; 10.6 mSv), LD80 (8.2 +/- 0.7; 2.6 mSv), LD30 (6.8 +/- 1.3; 1.0 mSv), and LD10 (4.6 +/- 1.9; 0.3 mSv). Thus, LD30 was the protocol using the lowest but sufficient dose. Moreover, for LD30 further differentiation between the particular window settings resulted in scores of 6.4 +/- 1.3 (L), 6.3 +/- 1.2 (V), and 3.1 +/- 1.0 (S). Conclusions With appropriate window settings, low-dose CT at 30 mA allowed for sufficient body-pack delineation below the dose of CR, which itself performed insufficient.
引用
收藏
页码:170 / 178
页数:9
相关论文
共 50 条
  • [1] Low-dose CT in body-packers: delineation of body packs and radiation dose in a porcine model
    Michael K. Scherr
    Oliver Peschel
    Jochen M. Grimm
    Edvard Ziegeler
    Michael Uhl
    Lucas L. Geyer
    Maximilian F. Reiser
    Stefan Wirth
    Forensic Science, Medicine, and Pathology, 2014, 10 : 170 - 178
  • [2] Computed tomography scout views vs. conventional radiography in body-packers - Delineation of body-packs and radiation dose in a porcine model
    Ziegeler, Edvard
    Grimm, Jochen M.
    Wirth, Stefan
    Uhl, Michael
    Reiser, Maximilian F.
    Scherr, Michael K.
    EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (12) : 3883 - 3889
  • [3] Body packing, body stuffing and body pushing: Characteristics and pitfalls on low-dose CT
    Puntonet, Julien
    Gorgiard, Charlotte
    Soussy, Nicolas
    Soyer, Philippe
    Dion, Elisabeth
    CLINICAL IMAGING, 2021, 79 : 244 - 250
  • [4] Systematic Evaluation of Radiation Dose Reduction in CT Studies of Body Packers: Accuracy Down to Submillisievert Levels
    Laberke, Patrick J.
    Blum, Simon
    Waelti, Stephan
    Fornaro, Juergen
    Hausmann, Roland
    Alkadhi, Hatem
    Leschka, Sebastian
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2016, 206 (04) : 740 - 746
  • [5] Diagnostic value of CT-localizer and axial low-dose computed tomography for the detection of drug body packing
    Aissa, Joel
    Kohlmeier, Antonia
    Rubbert, Christian
    Hohn, Ulrich
    Blondin, Dirk
    Schleich, Christoph
    Kroepil, Patric
    Boos, Johannes
    Antoch, Gerald
    Miese, Falk
    JOURNAL OF FORENSIC AND LEGAL MEDICINE, 2016, 37 : 55 - 60
  • [6] State of the art low-dose CT angiography of the body
    Alkadhi, Hatem
    Schindera, Sebastian T.
    EUROPEAN JOURNAL OF RADIOLOGY, 2011, 80 (01) : 36 - 40
  • [7] Sensitivity and specificity of CT scanning for determining the number of internally concealed packages in 'body-packers'
    Asha, Stephen Edward
    Higham, Matthew
    Child, Peter
    EMERGENCY MEDICINE JOURNAL, 2015, 32 (05) : 387 - 391
  • [8] Reducing Radiation Dose in Body CT: A Primer on Dose Metrics and Key CT Technical Parameters
    Maldjian, Pierre D.
    Goldman, Alice R.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2013, 200 (04) : 741 - 747
  • [9] Not Every Low-Dose Is Low-Dose: Impact of Revising Low-Dose CT Protocol on Mean Effective Radiation Exposure
    Deyirmendjian, Claudia
    Lee, Seohyuk
    Noureldin, Yasser A.
    Hegyi, Gyorgy
    Stein, Lawrence
    Artho, Giovanni
    Andonian, Sero
    JOURNAL OF ENDOUROLOGY, 2022, 36 (06) : 835 - 840
  • [10] Understanding the harm of low-dose computed tomography radiation to the body (Review)
    Shi, Hai-Min
    Sun, Zhi-Chao
    Ju, Fang-He
    EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2022, 24 (02)