Electrochemically synthesized partially reduced graphene oxide modified glassy carbon electrode for individual and simultaneous voltammetric determination of ascorbic acid, dopamine and uric acid

被引:39
|
作者
Aneesh, Padamadathil K. [1 ]
Nambiar, Sindhu R. [1 ]
Rao, Talasila P. [1 ]
Ajayaghosh, Ayyappanpillai [1 ]
机构
[1] CSIR, NIIST, CSTD, Trivandrum 695019, Kerala, India
关键词
SELECTIVE DETERMINATION; GRAPHITE OXIDE; SENSOR; NANOPARTICLES; NANOSHEETS; REDUCTION; FILM; NANOSTRUCTURES; POLYPYRROLE; THICKNESS;
D O I
10.1039/c4ay00043a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We report here an efficient and simple approach for the preparation of a partially reduced graphene oxide modified glassy carbon electrode (RGO-GCE). The modification of the RGO-GCE consists of three steps. These include (i) chemical synthesis of graphite oxide by a modified Hummer's method, (ii) exfoliation of graphite oxide to graphene oxide (GO) by ultra-sonication and (iii) controlled partial electrochemical reduction in 0.1 M phosphate buffered medium (pH 3.0) via potentiodynamic cycling (2 cycles) to obtain a partially reduced graphene oxide modified glassy carbon electrodes (RGO-GCE). The behaviour of the RGO-GCE towards ascorbic acid (AA), dopamine (DA) and uric acid (UA) was investigated by differential pulse voltammetry, with an enrichment time of 3 minutes. This showed that the modified electrode has good precision (1.42, 1.92 and 2.20% for AA, DA and UA, respectively) and resolution at pH 3.0 for all three molecules, which enables their individual and simultaneous determination. Under the optimized conditions, the electrochemical sensor showed a wider linear response for AA, DA and UA in the concentration ranges of 4 x 10(-5) to 1 x 10(-3) M, 1 x 10(-7) to 1 x 10(-4) M and 8 x 10(-7) to 8 x 10(-4) M with detection limits of 4.2 x 10(-6), 8 x 10(-9) and 6 x 10(-7) M, respectively, based on 3 times the standard deviation of the blank with minimal fouling effects. Detailed spectral (IR and Raman), morphological (SEM and TEM) and electrochemical characterization studies were also reported. Finally, the performance of the RGO-GCE based sensor was successfully tested for analysing UA and quantitative recoveries of AA and DA in serum samples.
引用
收藏
页码:5322 / 5330
页数:9
相关论文
共 50 条
  • [41] Docosyltrimethylammonium chloride modified glassy carbon electrode for simultaneous determination of dopamine and ascorbic acid
    Luo, Li-Qiang
    Li, Qiu-Xia
    Ding, Ya-Ping
    Zhang, Ying
    Shen, Xia
    JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2010, 14 (07) : 1311 - 1316
  • [42] Electrochemical Behavior and Voltammetric Determination of Curcumin at Electrochemically Reduced Graphene Oxide Modified Glassy Carbon Electrode
    Zhang, Dongdong
    Ouyang, Xiaoyan
    Ma, Jing
    Li, Lingzhi
    Zhang, Yanmin
    ELECTROANALYSIS, 2016, 28 (04) : 749 - 756
  • [43] Overoxidized polyimidazole/graphene oxide copolymer modified electrode for the simultaneous determination of ascorbic acid, dopamine, uric acid, guanine and adenine
    Liu, Xiaofang
    Zhang, Ling
    Wei, Shaping
    Chen, Shihong
    Ou, Xin
    Lu, Qiyi
    BIOSENSORS & BIOELECTRONICS, 2014, 57 : 232 - 238
  • [44] Gold nanoparticle decorated polypyrrole/graphene oxide nanosheets as a modified electrode for simultaneous determination of ascorbic acid, dopamine and uric acid
    Tan, Chaoli
    Zhao, Jie
    Sun, Peng
    Zheng, Wei
    Cui, Guofeng
    NEW JOURNAL OF CHEMISTRY, 2020, 44 (12) : 4916 - 4926
  • [45] Poly(glycine)/graphene oxide modified glassy carbon electrode: Preparation, characterization and simultaneous electrochemical determination of dopamine, uric acid, guanine and adenine
    He, Shaoying
    He, Ping
    Zhang, Xingquan
    Zhang, Xiaojuan
    Liu, Kaili
    Jia, Lingpu
    Dong, Faqin
    ANALYTICA CHIMICA ACTA, 2018, 1031 : 75 - 82
  • [46] Electrodeposition synthesis of reduced graphene oxide-carbon nanotube hybrids on indium tin oxide electrode for simultaneous electrochemical detection of ascorbic acid, dopamine and uric acid
    Zhang, Yong
    Ji, Ye
    Wang, Ziying
    Liu, Sen
    Zhang, Tong
    RSC ADVANCES, 2015, 5 (129) : 106307 - 106314
  • [47] Polystyrene sulphonate wrapped multiwalled carbon nanotubes modified graphite electrode for simultaneous determination of ascorbic acid, dopamine and uric acid
    Kumar, Simson Prasanna
    Manjunatha, Revanasiddappa
    Venkatesha, Thimmappa Venkatarangaiah
    Suresh, Gurukar Shivappa
    RUSSIAN JOURNAL OF ELECTROCHEMISTRY, 2013, 49 (04) : 299 - 306
  • [48] Simultaneous determination of dopamine, ascorbic acid, and uric acid using helical carbon nanotubes modified electrode
    Cui, Rongjing
    Wang, Xueying
    Zhang, Genhua
    Wang, Chen
    SENSORS AND ACTUATORS B-CHEMICAL, 2012, 161 (01): : 1139 - 1143
  • [49] Selective Determination of Dopamine, Ascorbic Acid and Uric Acid at SDS-MWCNTs Modified Glassy Carbon Electrode
    Zhang, Jian
    Zhu, Zhixin
    Zhu, Jianling
    Li, Kechang
    Hua, Shucheng
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2014, 9 (03): : 1264 - 1272
  • [50] Simultaneous electrochemical determination of dopamine, ascorbic acid and uric acid using poly(acid chrome blue K) modified glassy carbon electrode
    Zhang, Rui
    Jin, Gen-Di
    Chen, Da
    Hu, Xiao-Ya
    SENSORS AND ACTUATORS B-CHEMICAL, 2009, 138 (01): : 174 - 181