Electrochemically synthesized partially reduced graphene oxide modified glassy carbon electrode for individual and simultaneous voltammetric determination of ascorbic acid, dopamine and uric acid

被引:39
|
作者
Aneesh, Padamadathil K. [1 ]
Nambiar, Sindhu R. [1 ]
Rao, Talasila P. [1 ]
Ajayaghosh, Ayyappanpillai [1 ]
机构
[1] CSIR, NIIST, CSTD, Trivandrum 695019, Kerala, India
关键词
SELECTIVE DETERMINATION; GRAPHITE OXIDE; SENSOR; NANOPARTICLES; NANOSHEETS; REDUCTION; FILM; NANOSTRUCTURES; POLYPYRROLE; THICKNESS;
D O I
10.1039/c4ay00043a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We report here an efficient and simple approach for the preparation of a partially reduced graphene oxide modified glassy carbon electrode (RGO-GCE). The modification of the RGO-GCE consists of three steps. These include (i) chemical synthesis of graphite oxide by a modified Hummer's method, (ii) exfoliation of graphite oxide to graphene oxide (GO) by ultra-sonication and (iii) controlled partial electrochemical reduction in 0.1 M phosphate buffered medium (pH 3.0) via potentiodynamic cycling (2 cycles) to obtain a partially reduced graphene oxide modified glassy carbon electrodes (RGO-GCE). The behaviour of the RGO-GCE towards ascorbic acid (AA), dopamine (DA) and uric acid (UA) was investigated by differential pulse voltammetry, with an enrichment time of 3 minutes. This showed that the modified electrode has good precision (1.42, 1.92 and 2.20% for AA, DA and UA, respectively) and resolution at pH 3.0 for all three molecules, which enables their individual and simultaneous determination. Under the optimized conditions, the electrochemical sensor showed a wider linear response for AA, DA and UA in the concentration ranges of 4 x 10(-5) to 1 x 10(-3) M, 1 x 10(-7) to 1 x 10(-4) M and 8 x 10(-7) to 8 x 10(-4) M with detection limits of 4.2 x 10(-6), 8 x 10(-9) and 6 x 10(-7) M, respectively, based on 3 times the standard deviation of the blank with minimal fouling effects. Detailed spectral (IR and Raman), morphological (SEM and TEM) and electrochemical characterization studies were also reported. Finally, the performance of the RGO-GCE based sensor was successfully tested for analysing UA and quantitative recoveries of AA and DA in serum samples.
引用
收藏
页码:5322 / 5330
页数:9
相关论文
共 50 条
  • [31] Synergistic Effect of Graphene and Multiwalled Carbon Nanotubes on a Glassy Carbon Electrode for Simultaneous Determination of Uric Acid and Dopamine in the Presence of Ascorbic Acid
    He, Sijing
    Yu, Yanyan
    Chen, Zuanguang
    Shi, Qiujia
    Zhang, Lin
    ANALYTICAL LETTERS, 2015, 48 (02) : 248 - 258
  • [32] Simultaneous determination of ascorbic acid, dopamine and uric acid using poly(4-aminobutyric acid) modified glassy carbon electrode
    Zheng, Xinyu
    Zhou, Xuechou
    Ji, Xiaoyan
    Lin, Ruiyu
    Lin, Wenxiong
    SENSORS AND ACTUATORS B-CHEMICAL, 2013, 178 : 359 - 365
  • [33] Simultaneous Electrochemical Determination of Ascorbic Acid, Dopamine and Uric Acid Based on Nitrogen Doped Carbon Sphere Modified Glassy Carbon Electrode
    Ye, Fucheng
    Wen, Zubiao
    Wu, Hongfu
    Wang, Chunyan
    Qian, Yong
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2015, 10 (02): : 1136 - 1143
  • [34] Nano-Cu/PSA III modified glassy carbon electrode for simultaneous determination of ascorbic acid, dopamine and uric acid
    Zhang, Lei
    Yuan, Wen-Juan
    Hou, Bao-Qin
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2013, 689 : 135 - 141
  • [35] Simultaneous Determination of Ascorbic Acid, Dopamine and Uric Acid, at a Graphene Paste Electrode Modified with Functionalized Graphene Sheets
    Parvin, Mohammad Hadi
    ELECTROANALYSIS, 2015, 27 (06) : 1394 - 1402
  • [36] Simultaneous Determination of Dopamine and Uric Acid in the Presence of Ascorbic Acid at the Indole-3-Carboxaldehyde Modified Glassy Carbon Electrode
    Deletioglu, Didem
    Hasdemir, Erdogan
    Solak, Ali O.
    CURRENT ANALYTICAL CHEMISTRY, 2010, 6 (03) : 203 - 208
  • [37] Construction of cationic polyfluorinated azobenzene/reduced graphene oxide for simultaneous determination of dopamine, uric acid and ascorbic acid
    Wu, Shining
    Wang, Haoran
    Zhao, Bo
    Cao, Tongtong
    Ma, Juanjuan
    Liu, Lin
    Tong, Zhiwei
    TALANTA, 2022, 237
  • [38] Simultaneous electrochemical determination of epinephrine and uric acid in the presence of ascorbic acid using SnO2/graphene nanocomposite modified glassy carbon electrode
    Lavanya, N.
    Fazio, E.
    Neri, F.
    Bonavita, A.
    Leonardi, S. G.
    Neri, G.
    Sekar, C.
    SENSORS AND ACTUATORS B-CHEMICAL, 2015, 221 : 1412 - 1422
  • [39] Electrochemically functionalized carbon cloth for simultaneous determination of ascorbic acid, dopamine, and uric acid
    Ding, Shuang
    Dai, Manxia
    Su, Xinglin
    Guo, Di
    Bian, Lijun
    Liu, Xiaoxia
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2022, 915
  • [40] Fabrication of Amine-Modified Magnetite-Electrochemically Reduced Graphene Oxide Nanocomposite Modified Glassy Carbon Electrode for Sensitive Dopamine Determination
    He, Quanguo
    Liu, Jun
    Liu, Xiaopeng
    Li, Guangli
    Chen, Dongchu
    Deng, Peihong
    Liang, Jing
    NANOMATERIALS, 2018, 8 (04):