Electrochemically synthesized partially reduced graphene oxide modified glassy carbon electrode for individual and simultaneous voltammetric determination of ascorbic acid, dopamine and uric acid

被引:39
|
作者
Aneesh, Padamadathil K. [1 ]
Nambiar, Sindhu R. [1 ]
Rao, Talasila P. [1 ]
Ajayaghosh, Ayyappanpillai [1 ]
机构
[1] CSIR, NIIST, CSTD, Trivandrum 695019, Kerala, India
关键词
SELECTIVE DETERMINATION; GRAPHITE OXIDE; SENSOR; NANOPARTICLES; NANOSHEETS; REDUCTION; FILM; NANOSTRUCTURES; POLYPYRROLE; THICKNESS;
D O I
10.1039/c4ay00043a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We report here an efficient and simple approach for the preparation of a partially reduced graphene oxide modified glassy carbon electrode (RGO-GCE). The modification of the RGO-GCE consists of three steps. These include (i) chemical synthesis of graphite oxide by a modified Hummer's method, (ii) exfoliation of graphite oxide to graphene oxide (GO) by ultra-sonication and (iii) controlled partial electrochemical reduction in 0.1 M phosphate buffered medium (pH 3.0) via potentiodynamic cycling (2 cycles) to obtain a partially reduced graphene oxide modified glassy carbon electrodes (RGO-GCE). The behaviour of the RGO-GCE towards ascorbic acid (AA), dopamine (DA) and uric acid (UA) was investigated by differential pulse voltammetry, with an enrichment time of 3 minutes. This showed that the modified electrode has good precision (1.42, 1.92 and 2.20% for AA, DA and UA, respectively) and resolution at pH 3.0 for all three molecules, which enables their individual and simultaneous determination. Under the optimized conditions, the electrochemical sensor showed a wider linear response for AA, DA and UA in the concentration ranges of 4 x 10(-5) to 1 x 10(-3) M, 1 x 10(-7) to 1 x 10(-4) M and 8 x 10(-7) to 8 x 10(-4) M with detection limits of 4.2 x 10(-6), 8 x 10(-9) and 6 x 10(-7) M, respectively, based on 3 times the standard deviation of the blank with minimal fouling effects. Detailed spectral (IR and Raman), morphological (SEM and TEM) and electrochemical characterization studies were also reported. Finally, the performance of the RGO-GCE based sensor was successfully tested for analysing UA and quantitative recoveries of AA and DA in serum samples.
引用
收藏
页码:5322 / 5330
页数:9
相关论文
共 50 条
  • [21] Preparation of a glassy carbon electrode modified with reduced graphene oxide and overoxidized electropolymerized polypyrrole, and its application to the determination of dopamine in the presence of ascorbic acid and uric acid
    Xia Chen
    Dandan Li
    Weina Ma
    Tianfeng Yang
    Yanmin Zhang
    Dongdong Zhang
    Microchimica Acta, 2019, 186
  • [22] Differential Pulse Voltammetric Determination of Folic Acid in the Presence of Ascorbic Acid using A Glassy Carbon Electrode Modified with Reduced Graphene Oxide
    Abd-Elsabour, Mohamed
    Toghan, Arafat
    Abo-bakr, Ahmed M.
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2022, 14 (08): : 789 - 805
  • [23] A glassy carbon electrode modified with porous Cu2O nanospheres on reduced graphene oxide support for simultaneous sensing of uric acid and dopamine with high selectivity over ascorbic acid
    Mei, Li-Ping
    Feng, Jiu-Ju
    Wu, Liang
    Chen, Jian-Rong
    Shen, Liguo
    Xie, Yunlong
    Wang, Ai-Jun
    MICROCHIMICA ACTA, 2016, 183 (06) : 2039 - 2046
  • [24] Simultaneous Determination of Ascorbic Acid, Dopamine and Uric Acid with Chitosan-Graphene Modified Electrode
    Han, Dongxue
    Han, Tingting
    Shan, Changsheng
    Ivaska, Ari
    Niu, Li
    ELECTROANALYSIS, 2010, 22 (17-18) : 2001 - 2008
  • [25] Development of a porous reduced graphene oxide modified electrode for simultaneous determination of dopamine and uric acid
    Agadi, Naveenkumar P.
    Tandel, Ranjita
    Seetharamappa, J.
    IONICS, 2023, 29 (11) : 4863 - 4873
  • [26] Carbon nanohorns/poly(glycine) modified glassy carbon electrode: Preparation, characterization and simultaneous electrochemical determination of uric acid, dopamine and ascorbic acid
    Zhang, Guangli
    He, Ping
    Feng, Wanru
    Ding, Shuangshuang
    Chen, Jingchao
    Li, Lian
    He, Huichao
    Zhang, Susu
    Dong, Faqin
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2016, 760 : 24 - 31
  • [27] Reduced Graphene Oxide/Polydopamine/Gold Electrode as Elecrochemical Sensor for Simultaneous Determination of Ascorbic Acid, Dopamine, and Uric Acid
    Shi, Ling
    Wang, Zefeng
    Chen, Xianlan
    Yang, Guangming
    Liu, Wei
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2019, 14 (09): : 8882 - 8891
  • [28] Novel graphene flowers modified carbon fibers for simultaneous determination of ascorbic acid, dopamine and uric acid
    Du, Jiao
    Yue, Ruirui
    Ren, Fangfang
    Yao, Zhangquan
    Jiang, Fengxing
    Yang, Ping
    Du, Yukou
    BIOSENSORS & BIOELECTRONICS, 2014, 53 : 220 - 224
  • [29] A glassy carbon electrode modified with electrochemically reduced graphene for simultaneous determination of guanine and adenine
    Zhu, Xiaohua
    Zeng, Lixuan
    Xu, Maotian
    Liang, Yong
    Nan, Junmin
    ANALYTICAL METHODS, 2012, 4 (09) : 2935 - 2939
  • [30] Novel water-soluble multi-nanopore graphene modified glassy carbon electrode for simultaneous determination of dopamine and uric acid in the presence of ascorbic acid
    Zhu, Xiaohua
    Liang, Yong
    Zuo, Xiaoxi
    Hu, Ruiping
    Xiao, Xin
    Nan, Junmin
    ELECTROCHIMICA ACTA, 2014, 143 : 366 - 373