Effect of the geometry of the intraoral position-indicating device on effective dose

被引:9
作者
Cederberg, RA [1 ]
Frederiksen, NL [1 ]
Benson, BW [1 ]
Sokolowski, TW [1 ]
机构
[1] BAYLOR UNIV,MED CTR,SAMMONS CANC CTR,TEXAS ONCOL,DALLAS,TX
来源
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS | 1997年 / 84卷 / 01期
关键词
D O I
10.1016/S1079-2104(97)90304-8
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective. The objective of this study was to calculate and compare the effective dose and to estimate risk from the use of intraoral position-indicating devices of differing geometries. Study design. Thermoluminescent dosimeters were placed at selected sites in the upper portion of a tissue-equivalent human phantom to record the equivalent dose to weighted tissues and organs. The phantom was exposed to simulated complete mouth surveys with either a long (29.8 cm) or short (19.6 cm) round open-end position-indicating device, a long (35.3 cmi or short (23.3 cm) rectangular open-end position-indicating device, or a pointed (29.6 cm) closed-end position-indicating device. Results. The effective dose was calculated as the sum of the equivalent doses to each organ or tissue multiplied by that organ or tissue's weighting factor. The salivary glands were included as part of the remainder. The effective dose ranged from 362 mu Sv for the pointed position-indicating device, to 63 mu Sv for both the long and the short rectangular position-indicating devices. Conclusions. These effective doses were calculated to represent a probability for stochastic effects that range in magnitude from 26 x 10(-6) to 4.6 x 10(-6).
引用
收藏
页码:101 / 109
页数:9
相关论文
共 22 条
[1]  
ALCOX RW, 1978, DENT CLIN N AM, V22, P517
[2]  
[Anonymous], ICRP PUBL
[3]   Effective dose and risk assessment from detailed narrow beam radiography [J].
Avendanio, B ;
Frederiksen, NL ;
Benson, BW ;
Sokolowski, TW .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1996, 82 (06) :713-719
[4]  
Barrell John, 1980, DARK SIDE LANDSCAPE, P35
[5]   DISTRIBUTION OF ACTIVE BONE MARROW IN ADULT [J].
ELLIS, RE .
PHYSICS IN MEDICINE AND BIOLOGY, 1961, 5 (03) :255-&
[6]   EFFECTIVE DOSE AND RISK ASSESSMENT FROM FILM TOMOGRAPHY USED FOR DENTAL IMPLANT DIAGNOSTICS [J].
FREDERIKSEN, NL ;
BENSON, BW ;
SOKOLOWSKI, TW .
DENTOMAXILLOFACIAL RADIOLOGY, 1994, 23 (03) :123-127
[7]  
Gibbs S J, 1988, Dentomaxillofac Radiol, V17, P15
[8]   INFLUENCE OF ORGANS IN THE ICRPS REMAINDER ON EFFECTIVE DOSE EQUIVALENT COMPUTED FOR DIAGNOSTIC RADIATION EXPOSURES [J].
GIBBS, SJ .
HEALTH PHYSICS, 1989, 56 (04) :515-520
[9]  
Goaz P.W., 1994, ORAL RADIOLOGY PRINC
[10]   DETERMINATION AND ANALYSIS OF ABSORBED DOSES RESULTING FROM VARIOUS INTRAORAL RADIOGRAPHIC TECHNIQUES [J].
GREER, DF .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1972, 34 (01) :146-&