Removal of contaminants from underground spaces by induced ventilation

被引:4
作者
Ziskind, G [1 ]
Dubovsky, V [1 ]
Letan, R [1 ]
机构
[1] Ben Gurion Univ Negev, Dept Mech Engn, Heat Transfer Lab, IL-84105 Beer Sheva, Israel
来源
JOURNAL OF ENVIRONMENTAL ENGINEERING-ASCE | 2002年 / 128卷 / 08期
关键词
abatement and removal; contaminants; ventilation; underground structures; airflow;
D O I
10.1061/(ASCE)0733-9372(2002)128:8(673)
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The present paper introduces induced airflow as an effective means for removal of contaminants from underground enclosed spaces. The airflow is caused by natural convection in a vertical duct which absorbs solar irradiation outside the building. Experimental studies and three-dimensional numerical simulations have been performed in a scaled-down laboratory model. The experiments included temperature and velocity measurements and flow visualization. The results obtained from the simulations are fully supported by the experimental results, indicating that effective ventilation by the proposed method is achievable. For real-size structures, three-dimensional computer simulations have been performed using a standard k-epsilon turbulence model. The results yield a detailed flow field inside the enclosure for various configurations of the ducts and partitions. Rate of air change is calculated both for the whole enclosure, and for the regions above the floor where contaminants like radon tend to accumulate. By adjustment of openings in the basement, the ceiling may be cleared of contaminants as well. It is shown that a properly designed structure, even at low solar fluxes, can provide adequate ventilation of a real-size underground enclosure.
引用
收藏
页码:673 / 688
页数:16
相关论文
共 13 条
[1]   Solar chimneys: simulation and experiment [J].
Afonso, C ;
Oliveira, A .
ENERGY AND BUILDINGS, 2000, 32 (01) :71-79
[2]   SOLAR CHIMNEY FOR ENHANCED STACK VENTILATION [J].
BANSAL, NK ;
MATHUR, R ;
BHANDARI, MS .
BUILDING AND ENVIRONMENT, 1993, 28 (03) :373-377
[3]   Natural convection inside ventilated enclosure heated by downward-facing plate: experiments and numerical simulations [J].
Dubovsky, V ;
Ziskind, G ;
Druckman, S ;
Moshka, E ;
Weiss, Y ;
Letan, R .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2001, 44 (16) :3155-3168
[4]   Study of natural ventilation of houses by a metallic solar wall under tropical climate [J].
Hirunlabh, J ;
Kongduang, W ;
Namprakai, P ;
Khedari, J .
RENEWABLE ENERGY, 1999, 18 (01) :109-119
[5]   Indoor air quality and health [J].
Jones, AP .
ATMOSPHERIC ENVIRONMENT, 1999, 33 (28) :4535-4564
[6]   Ventilation impact of a solar chimney on indoor temperature fluctuation and air change in a school building [J].
Khedari, J ;
Boonsri, B ;
Hirunlabh, J .
ENERGY AND BUILDINGS, 2000, 32 (01) :89-93
[7]   Field measurements of performance of roof solar collector [J].
Khedari, J ;
Mansirisub, W ;
Chaima, S ;
Pratinthong, N ;
Hirunlabh, J .
ENERGY AND BUILDINGS, 2000, 31 (03) :171-178
[8]  
Korhonen PA, 1997, AM IND HYG ASSOC J, V58, P366
[9]   Effects of air conditioning, dehumidification and natural ventilation on indoor concentrations of 222Rn and 220Rn [J].
Lee, TKC ;
Yu, KN .
JOURNAL OF ENVIRONMENTAL RADIOACTIVITY, 2000, 47 (02) :189-199
[10]  
LETAN R, IN PRESS BUILD ENV