Analysis of spatial diffusion of ferric ions in PVA-GTA gel dosimeters through magnetic resonance imaging

被引:42
作者
Marrale, Maurizio [1 ,2 ,3 ]
Collura, Giorgio [1 ,2 ]
Gallo, Salvatore [1 ,2 ,4 ]
Nici, Stefania [1 ]
Tranchina, Luigi [3 ]
Abbate, Boris Federico [5 ]
Marineo, Sandra [6 ]
Caracappa, Santo [6 ]
d'Errico, Francesco [7 ,8 ]
机构
[1] Univ Palermo, Dipartimento Fis & Chim, Viale Sci,Edificio 18, I-90128 Palermo, Italy
[2] Ist Nazl Fis Nucl, Grp Sez Catania 5, Via Santa Sofia 64, I-95123 Catania, Italy
[3] Univ Palermo, ATeN Ctr, Viale Sci,Edificio 18, I-90128 Palermo, Italy
[4] Univ Milan, Dipartimento Fis, Via Giovanni Celoria 16, I-20133 Milan, Italy
[5] Osped Civ Palermo, ARNAS, UOC Fis Sanitaria, Piazza Nicola Leotta 4, I-90127 Palermo, Italy
[6] Ist Zooprofilatt Sperimentale Sicilia IZS, Via Gino Marinuzzi 3, I-90129 Palermo, Italy
[7] Univ Pisa, Dipartimento Ingn Civile & Ind, Largo Lucia Lazzarino 2, I-56126 Pisa, Italy
[8] Sch Med Yale, Magnet Resonance Res Ctr, 300 Cedar St,POB 208043, New Haven, CT 06520 USA
关键词
Gel dosimetry; PVA gel; Agarose gel; Magnetic resonance imaging; Clinical photons beam; RADIATION-DOSE DISTRIBUTIONS; PHENOL COMPOUNDS; OUTPUT FACTORS; OPTICAL-FIBER; NMR; SENSITIVITY; STABILITY; FIELD; EPR; VERIFICATION;
D O I
10.1016/j.nimb.2017.02.008
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
This work focused on the analysis of the temporal diffusion of ferric ions through PVA-GTA gel dosimeters. PVA-GTA gel samples, partly exposed with 6 MV X-rays in order to create an initial steep gradient, were mapped using magnetic resonance imaging on a 7T MRI scanner for small animals. Multiple images of the gels were acquired over several hours after irradiation and were analyzed to quantitatively extract the signal profile. The spatial resolution achieved is 200 mu m and this makes this technique particularly suitable for the analysis of steep gradients of ferric ion concentration. The results obtained with PVA-GTA gels were compared with those achieved with agarose gels, which is a standard dosimetric gel formulation. The analysis showed that the diffusion process is much slower (more than five times) for PVA-GTA gels than for agarose ones. Furthermore, it is noteworthy that the diffusion coefficient value obtained through MRI analysis is significantly consistent with that obtained in separate study Marini et al. (Submitted for publication) using a totally independent method such as spectrophotometry. This is a valuable result highlighting that the good dosimetric features of this gel matrix not only can be reproduced but also can be measured through independent experimental techniques based on different physical principles. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:50 / 55
页数:6
相关论文
共 54 条
[1]  
Andreo P., 398 IAEA TRS
[2]   Three-dimensional dosimetry of small megavoltage radiation fields using radiochromic gels and optical CT scanning [J].
Babic, Steven ;
McNiven, Andrea ;
Battista, Jerry ;
Jordan, Kevin .
PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (08) :2463-2481
[3]   Clinical applications of alanine/electron spin resonance dosimetry [J].
Baffa, Oswaldo ;
Kinoshita, Angela .
RADIATION AND ENVIRONMENTAL BIOPHYSICS, 2014, 53 (02) :233-240
[4]   Polymer gel dosimetry [J].
Baldock, C. ;
De Deene, Y. ;
Doran, S. ;
Ibbott, G. ;
Jirasek, A. ;
Lepage, M. ;
McAuley, K. B. ;
Oldham, M. ;
Schreiner, L. J. .
PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (05) :R1-R63
[5]   Experimental determination of the diffusion coefficient in two-dimensions in ferrous sulphate gels using the finite element method [J].
Baldock C. ;
Harris P.J. ;
Piercy A.R. ;
Healy B. .
Australasian Physics & Engineering Sciences in Medicine, 2001, 24 (1) :19-30
[6]   Tissue-equivalent gel for non-invasive spatial radiation dose measurements [J].
Bero, MA ;
Gilboy, WB ;
Glover, PM ;
El-masri, HM .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2000, 166 :820-825
[7]   Development of silicon monolithic arrays for dosimetry in external beam radiotherapy [J].
Bisello, Francesca ;
Menichelli, David ;
Scaringella, Monica ;
Talamonti, Cinzia ;
Zani, Margherita ;
Bucciolini, Marta ;
Bruzzi, Mara .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 796 :85-88
[8]   Diamond detector versus silicon diode and ion chamber in photon beams of different energy and field size [J].
Bucciolini, M ;
Buonamici, FB ;
Mazzocchi, S ;
De Angelis, C ;
Onori, S ;
Cirrone, GAP .
MEDICAL PHYSICS, 2003, 30 (08) :2149-2154
[9]   Optical response of the FXG solution to different phantom materials [J].
Cavinato, C. C. ;
Sakuraba, R. K. ;
Cruz, J. C. ;
Campos, L. L. .
RADIATION MEASUREMENTS, 2011, 46 (12) :1928-1931
[10]   Polyvinyl alcohol-Fricke hydrogel and cryogel:: two new gel dosimetry systems with low Fe3+ diffusion [J].
Chu, KC ;
Jordan, KJ ;
Battista, JJ ;
Van Dyk, J ;
Rutt, BK .
PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (04) :955-969