High-Power (40-50 W) Radiofrequency Ablation Guided by Unipolar Signal Modification for Pulmonary Vein Isolation: Experimental Findings and Clinical Results

被引:58
作者
Pambrun, Thomas [1 ]
Durand, Cyril [2 ]
Constantin, Marion [1 ]
Masse, Alexandre [3 ]
Marra, Celine [3 ]
Meillet, Valentin [3 ]
Haissaguerre, Michel [1 ]
Jais, Pierre [1 ]
Bortone, Agustin [4 ]
机构
[1] Univ Bordeaux, CHU Bordeaux, Hop Cardiol Haut Leveque, Inst RYthmol & Modelisat Card LIRYC, Bordeaux, France
[2] Infirm Protestante, Dept Rythmol, Lyon, France
[3] Johnson & Johnson, Biosense Webster France, Issy Les Moulineaux, France
[4] Hop Prive Franciscaines, Serv Cardiol, Nimes, France
关键词
atrial fibrillation; human; pulmonary vein; radiofrequency ablation; swine; PAROXYSMAL ATRIAL-FIBRILLATION; CONTACT-FORCE; LESION CREATION; CATHETER; DURATION; ELECTROGRAM; SAFE;
D O I
10.1161/CIRCEP.119.007304
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Although proposed to facilitate pulmonary vein isolation (PVI), high-power ablation may favor extracardiac damage. Negative component abolition of the unipolar signal reflects lesion transmurality. The present study sought to evaluate the safety and efficacy of high-power ablation using unipolar signal modification as a local end point. Methods: High power and standard power were compared in 4 swine and 100 consecutive patients referred for PVI. The first 50 patients were included in the control group (25-30 W) and the last 50 patients in the study group (40-50 W). Atrial radiofrequency applications were stopped 2 s (study group and swine) or 5 s (control group) after unipolar signal modification. Ventricular radiofrequency applications of 500 J (25 W20 s versus 50 W10 s) were performed at the swine epicardium. Results: Swine gross necropsy did not show any extracardiac damage related to atrial lesions. At equal energy of 500 J, 50 W lesions were deeper (30.9 versus 2.6 +/- 1.1 mm; P=0.03) and wider (6.2 +/- 2 versus 5 +/- 2.3 mm; P=0.006) than 25 W lesions. No complications occurred during the clinical study, whatever the power output used for PVI. For a similar sinus rhythm maintenance at 12 months (90% versus 88%; P=0.75), the study group displayed higher first-pass PVI (92% versus 73%; P<0.001), lower acute pulmonary vein reconnection (2% versus 17%; P<0.001), reduced procedure time (73.1 +/- 18.2 versus 107.4 +/- 21.2 min; P<0.001), and ablation time (13 +/- 2.9 versus 30.3 +/- 8.8 min; P<0.001). Conclusions: High-power PVI guided by unipolar signal modification safely decreases procedural burden while ensuring robust 12-month outcomes.
引用
收藏
页数:9
相关论文
共 23 条
[1]   Five seconds of 50-60 W radio frequency atrial ablations were transmural and safe: an in vitro mechanistic assessment and force-controlled in vivo validation [J].
Bhaskaran, Abhishek ;
Chik, William ;
Pouliopoulos, Jim ;
Nalliah, Chrishan ;
Qian, Pierre ;
Barry, Tony ;
Nadri, Fazlur ;
Samanta, Rahul ;
Tran, Ying ;
Thomas, Stuart ;
Kovoor, Pramesh ;
Thiagalingam, Aravinda .
EUROPACE, 2017, 19 (05) :874-880
[2]   Longer Duration Versus Increasing Power During Radiofrequency Ablation Yields Different Ablation Lesion Characteristics [J].
Borne, Ryan T. ;
Sauer, William H. ;
Zipse, Matthew M. ;
Zheng, Lijun ;
Tzou, Wendy ;
Nguyen, Duy T. .
JACC-CLINICAL ELECTROPHYSIOLOGY, 2018, 4 (07) :902-908
[3]   Elimination of the Negative Component of the Unipolar Atrial Electrogram as an In Vivo Marker of Transmural Lesion Creation Acute Study in Canines [J].
Bortone, Agustin ;
Brault-Noble, Guillaume ;
Appetiti, Anthony ;
Marijon, Eloi .
CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2015, 8 (04) :905-911
[4]   Unipolar Signal Modification as a Guide for Lesion Creation During Radiofrequency Application in the Left Atrium Prospective Study in Humans in the Setting of Paroxysmal Atrial Fibrillation Catheter Ablation [J].
Bortone, Agustin ;
Appetiti, Anthony ;
Bouzeman, Abdeslam ;
Maupas, Eric ;
Ciobotaru, Vlad ;
Boulenc, Jean-Marc ;
Pujadas-Berthault, Penelope ;
Rioux, Philippe .
CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2013, 6 (06) :1095-1102
[5]   High-power short-duration versus standard radiofrequency ablation: Insights on lesion metrics [J].
Bourier, Felix ;
Duchateau, Josselin ;
Vlachos, Konstantinos ;
Lam, Anna ;
Martin, Claire A. ;
Takigawa, Masateru ;
Kitamura, Takeshi ;
Frontera, Antonio ;
Cheniti, Ghassen ;
Pambrun, Thomas ;
Klotz, Nicolas ;
Denis, Arnaud ;
Derval, Nicolas ;
Cochet, Hubert ;
Sacher, Frederic ;
Hocini, Meleze ;
Haissaguerre, Michel ;
Jais, Pierre .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2018, 29 (11) :1570-1575
[6]   Novel ablative approach for atrial fibrillation to decrease risk of esophageal injury [J].
Bunch, T. Jared ;
Day, John D. .
HEART RHYTHM, 2008, 5 (04) :624-627
[7]  
Calkins H, 2017, HEART RHYTHM, V14, pE275, DOI [10.1093/europace/eux274, 10.1016/j.hrthm.2017.05.012, 10.1093/europace/eux275]
[8]  
Haines D., 2006, CATHETER ABLATION CA, P4
[9]  
Ho SY, 1999, J CARDIOVASC ELECTR, V10, P1525
[10]   Pulmonary vein antral isolation using an open irrigation ablation catheter for the treatment of atrial fibrillation - A randomized pilot study [J].
Kanj, Mohamed H. ;
Wazni, Oussama ;
Fahmy, Tamer ;
Thal, Sergio ;
Patel, Dimpi ;
Elay, Claude ;
Di Biase, Luigi ;
Arruda, Mauricio ;
Saliba, Walid ;
Schweikert, Robert A. ;
Cummings, Jennifer E. ;
Burkhardt, J. David ;
Martin, David O. ;
Pelargonio, Gemma ;
Dello Russo, Antonio ;
Casella, Michela ;
Santarelli, Pietro ;
Potenza, Domenico ;
Fanelli, Raffaele ;
Massaro, Raimondo ;
Forleo, Giovanni ;
Natale, Andrea .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 49 (15) :1634-1641