Development of a new dynamometer for measuring grip strength applied on a cylindrical handle

被引:45
|
作者
Wimer, Bryan [1 ]
Dong, Ren G. [1 ]
Welcome, Daniel E. [1 ]
Warren, Christopher [1 ]
McDowell, Thomas W. [1 ]
机构
[1] NIOSH, Engn & Control Technol Branch, Morgantown, WV 26505 USA
关键词
Grip force; Grip strength; Hand force; Instrumented handle; Dynamometer; HANDGRIP FORCE; INTERFACE; DIAMETERS;
D O I
10.1016/j.medengphy.2009.01.009
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The objective of this study is to enhance the understanding of the hand grip force applied to a cylindrical handle and to develop a new dynamometer for measuring maximum grip force or grip strength. Specifically, a 40 mm instrumented cylindrical handle with six measuring arms was developed. A theoretical model was proposed and used to analyze the principle of the measurement. Human test subjects were used in conclucting two sets of experiments to evaluate the handle and to assess the measurement method. This study confirmed that some friction force exists in the grip-only action, but its level is not comparable with the normal force. This study also found that the friction force can stabilize the grip action and marginally increase the grip strength. No reliable correlation between the grip strengths measured with the 40 mm cylindrical handle and Jamar handle with a 47.6 mm span was observed. This suggests that grip strength measured with Jamar handle may not be reliably applicable to the design and risk assessment of some tools or machines with cylindrical handles. In contrast, the cylindrical handle proved to be able to determine the overall grip strength for a subject, as well as show the grip force distribution around the circumference of the handle. The handle is accurate with less than 4% error, and it demonstrates that the measurement is independent of the loading position along the handle. Therefore, this study concluded that this new dynamometer is suitable for measuring grip strength with sufficient precision. Published by Elsevier Ltd on behalf of IPEM
引用
收藏
页码:695 / 704
页数:10
相关论文
共 50 条
  • [31] Development of a dynamometer to measure grip forces at a bicycle handlebar
    Krumm, Dominik
    Odenwald, Stephan
    ENGINEERING OF SPORT 10, 2014, 72 : 80 - 85
  • [32] Normal digital contribution to grip strength assessed by a computerized digital dynamometer
    Talsania, JS
    Kozin, SH
    JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 1998, 23B (02): : 162 - 166
  • [33] Relationship between hand size, grip strength and dynamometer position in women
    Fiebert, IM
    Roach, KE
    Fromdahl, JW
    Moyer, JD
    Pfeiffer, FF
    JOURNAL OF BACK AND MUSCULOSKELETAL REHABILITATION, 1998, 10 (03) : 137 - 142
  • [34] Dynamometer measurements of hand-grip strength predict multiple outcomes
    Bohannon, RW
    PERCEPTUAL AND MOTOR SKILLS, 2001, 93 (02) : 323 - 328
  • [35] EVALUATION OF METHODS FOR MEASURING GRIP STRENGTH
    SOLGAARD, S
    KRISTIANSEN, B
    JENSEN, JS
    ACTA ORTHOPAEDICA SCANDINAVICA, 1984, 55 (03): : 393 - 393
  • [36] EVALUATION OF INSTRUMENTS FOR MEASURING GRIP STRENGTH
    SOLGAARD, S
    KRISTIANSEN, B
    JENSEN, JS
    ACTA ORTHOPAEDICA SCANDINAVICA, 1984, 55 (05): : 569 - 572
  • [37] Reliability and validity of the hand-held dynamometer "NOD": a new instrument for assessment of isometric grip strength
    Sartorio, Francesco
    Lippi, Lorenzo
    Vercelli, Stefano
    Gallo, Federica
    Zanin, Davide
    Bergesio, Sara
    de Sire, Alessandro
    Invernizzi, Marco
    BMC MUSCULOSKELETAL DISORDERS, 2025, 26 (01)
  • [38] Power grip strength as a function of tool handle orientation and location
    McGorry, R. W.
    Lin, J.-H.
    ERGONOMICS, 2007, 50 (09) : 1392 - 1403
  • [39] Influence of elbow position and handle size on maximal grip strength
    Li, K.
    Hewson, D. J.
    Hogrel, J. -Y.
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2009, 34E (05) : 692 - 694
  • [40] The effect of handle shape and wrist posture on maximum grip strength
    Fredericks, TK
    ADVANCES IN OCCUPATIONAL ERGONOMICS AND SAFETY 1997, 1997, : 309 - 312