Development of a new dynamometer for measuring grip strength applied on a cylindrical handle

被引:45
|
作者
Wimer, Bryan [1 ]
Dong, Ren G. [1 ]
Welcome, Daniel E. [1 ]
Warren, Christopher [1 ]
McDowell, Thomas W. [1 ]
机构
[1] NIOSH, Engn & Control Technol Branch, Morgantown, WV 26505 USA
关键词
Grip force; Grip strength; Hand force; Instrumented handle; Dynamometer; HANDGRIP FORCE; INTERFACE; DIAMETERS;
D O I
10.1016/j.medengphy.2009.01.009
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The objective of this study is to enhance the understanding of the hand grip force applied to a cylindrical handle and to develop a new dynamometer for measuring maximum grip force or grip strength. Specifically, a 40 mm instrumented cylindrical handle with six measuring arms was developed. A theoretical model was proposed and used to analyze the principle of the measurement. Human test subjects were used in conclucting two sets of experiments to evaluate the handle and to assess the measurement method. This study confirmed that some friction force exists in the grip-only action, but its level is not comparable with the normal force. This study also found that the friction force can stabilize the grip action and marginally increase the grip strength. No reliable correlation between the grip strengths measured with the 40 mm cylindrical handle and Jamar handle with a 47.6 mm span was observed. This suggests that grip strength measured with Jamar handle may not be reliably applicable to the design and risk assessment of some tools or machines with cylindrical handles. In contrast, the cylindrical handle proved to be able to determine the overall grip strength for a subject, as well as show the grip force distribution around the circumference of the handle. The handle is accurate with less than 4% error, and it demonstrates that the measurement is independent of the loading position along the handle. Therefore, this study concluded that this new dynamometer is suitable for measuring grip strength with sufficient precision. Published by Elsevier Ltd on behalf of IPEM
引用
收藏
页码:695 / 704
页数:10
相关论文
共 50 条
  • [1] A new approach to characterize grip force applied to a cylindrical handle
    Dong, Ren G.
    Wu, John Z.
    Welcome, Daniel E.
    McDowell, Thomas W.
    MEDICAL ENGINEERING & PHYSICS, 2008, 30 (01) : 20 - 33
  • [2] A PRELIMINARY INVESTIGATION ON THE GRIP FORCE APPLIED ON A CYLINDRICAL HANDLE
    Wimer, Bryan M.
    Welcome, Daniel E.
    Warren, Chris
    McDowell, Thomas W.
    Dong, Ren G.
    PROCEEDINGS OF THE ASME SUMMER BIOENGINEERING CONFERENCE 2008, PTS A AND B, 2009, : 993 - 994
  • [3] Reliability and validity of an electronic dynamometer for measuring grip strength
    Allen, Deborah
    Barnett, Fiona
    INTERNATIONAL JOURNAL OF THERAPY AND REHABILITATION, 2011, 18 (05): : 258 - 264
  • [4] THE EFFECTS OF JAYMAR DYNAMOMETER HANDLE POSITION AND TEST PROTOCOL ON NORMAL GRIP STRENGTH
    FESS, EE
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1982, 7 (03): : 308 - 309
  • [5] Reliability and validity of an electronic dynamometer for measuring grip strength COMMENT
    Fitinghoff, Helene
    INTERNATIONAL JOURNAL OF THERAPY AND REHABILITATION, 2011, 18 (05): : 265 - 265
  • [6] Measuring Grip Strength in Older Adults: Comparing the Grip-ball With the Jamar Dynamometer
    Vermeulen, Joan
    Neyens, Jacques C. L.
    Spreeuwenberg, Marieke D.
    van Rossum, Erik
    Hewson, David J.
    de Witte, Luc P.
    JOURNAL OF GERIATRIC PHYSICAL THERAPY, 2015, 38 (03) : 148 - 153
  • [7] Development of a Dynamometer to Measure Grip Strength of Each Finger
    Makino, Koji
    Sato, Nobutaka
    Fujita, Koji
    Kanagawa, Takaiki
    Miyamamoto, Masaya
    Sasaki, Toru
    Haro, Hirotaka
    Kondo, Yasuo
    Terada, Hidetsugu
    2018 IEEE 27TH INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS (ISIE), 2018, : 1100 - 1105
  • [8] Development of an integrated digital hand grip dynamometer and norm of hand grip strength
    Chang, Ho
    Chen, Chih-Hao
    Huang, Tung-Sun
    Tai, Chun-Yen
    BIO-MEDICAL MATERIALS AND ENGINEERING, 2015, 26 : S611 - S617
  • [9] GRIP TEST - THE USE OF A DYNAMOMETER WITH ADJUSTABLE HANDLE SPACINGS
    BECHTOL, CO
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1954, 36-A (04): : 820 - &
  • [10] COMPARISON OF STOELTING HAND GRIP DYNAMOMETER AND LINEAR VOLTAGE DIFFERENTIAL TRANSFORMER FOR MEASURING MAXIMAL GRIP STRENGTH
    HEYWARD, V
    MCKEOWN, B
    GEESEMAN, R
    RESEARCH QUARTERLY, 1975, 46 (02): : 262 - 266