Meta-analysis of accuracy of intraocular lens power calculation formulas in short eyes

被引:72
作者
Wang, Qiwei [1 ]
Jiang, Wu [2 ]
Lin, Tiao [3 ]
Wu, Xiaohang [1 ]
Lin, Haotian [1 ]
Chen, Weirong [1 ]
机构
[1] Sun Yat Sen Univ, Zhongshan Ophthalm Ctr, State Key Lab Ophthalmol, Guangzhou, Guangdong, Peoples R China
[2] Sun Yat Sen Univ, Ctr Canc, State Key Lab Oncol South China, Collaborat Innovat Ctr Canc Med,Dept Colorectal S, Guangzhou, Guangdong, Peoples R China
[3] Sun Yat Sen Univ, Affiliated Hosp 1, Guangzhou, Guangdong, Peoples R China
基金
中国国家自然科学基金;
关键词
cataract; intraocular lens power; mean absolute error; short eyes; PARTIAL COHERENCE INTERFEROMETRY; CATARACT-SURGERY; HOFFER-Q; AXIAL LENGTH; BIOMETRY; HYPEROPIA; NANOPHTHALMOS; ABSENCE; ERROR; SRK/T;
D O I
10.1111/ceo.13058
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
ImportanceIntraocular lens (IOL) power selection is a critical factor affecting visual outcome after IOL implantation in short eyes. Many formulas have been developed to achieve a precise prediction of the IOL power. However, controversy regarding the accuracy remains. BackgroundTo investigate the accuracy of different IOL power calculation formulas in short eyes. DesignMeta-analysis. ParticipantsPatients with the axial length of eyes less than 22mm from previously reported studies. MethodsA comprehensive search in Pubmed, EMBASE, Cochrane Data Base of Systematic Reviews and the Cochrane Central Register of Controlled Trials was conducted by October 2016. We assessed the methodological quality using a modified QUADAS-2 tool and performed analysis on weighted mean differences of mean absolute errors (MAE) among different formulas. Main Outcomes MeasuresThe between-group difference of MAE was evaluated with weighted mean difference and 95% confidence intervals. ResultsTen observational studies, involving 1161 eyes, were enrolled to compare six formulas: Haigis, Holladay 2, Hoffer Q, Holladay 1, SRK/T and SRK II. Among them, the Holladay 2 introduced the smallest overall MAE (0.496D) without statistical significance. The difference of MAE is statistically significant between Haigis and Hoffer Q (mean difference=-0.07D, P=0.003), Haigis and SRK/T (mean difference=-0.07D, P=0.009), Haigis and SRK II (mean difference=-0.41D, P=0.01). For publication bias and small-study effect, neither funnel plot nor egger's test detected statistical finding. Conclusion and RelevanceThe overall evidence from the studies confirmed the superiority of Haigis over Hoffer Q, SRK/T and SRK II in prediction IOL power in short eyes.
引用
收藏
页码:356 / 363
页数:8
相关论文
共 32 条
[1]   Formula choice: Hoffer Q, Holladay 1, or SRK/T and refractive outcomes in 8108 eyes after cataract surgery with biometry by partial coherence interferometry [J].
Aristodemou, Petros ;
Cartwright, Nathaniel E. Knox ;
Sparrow, John M. ;
Johnston, Robert L. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (01) :63-71
[2]   Accuracy of the Refractive Prediction Determined by Multiple Currently Available Intraocular Lens Power Calculation Formulas in Small Eyes [J].
Carifi, Gianluca ;
Aiello, Francesco ;
Zygoura, Vasiliki ;
Kopsachilis, Nikolaos ;
Maurino, Vincenzo .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2015, 159 (03) :577-583
[3]   Comparison of 9 intraocular lens power calculation formulas [J].
Cooke, David L. ;
Cooke, Timothy L. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2016, 42 (08) :1157-1164
[4]   Accuracy of intraocular lens power calculations in eyes with axial length <22.00 mm [J].
Day, Alexander C. ;
Foster, Paul J. ;
Stevens, Julian D. .
CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2012, 40 (09) :855-862
[5]   Rapid fetal fibronectin testing to predict preterm birth in women with symptoms of premature labour: a systematic review and cost analysis [J].
Deshpande, S. N. ;
van Asselt, A. D. I. ;
Tomini, F. ;
Armstrong, N. ;
Allen, A. ;
Noake, C. ;
Khan, K. ;
Severens, J. L. ;
Kleijnen, J. ;
Westwood, M. E. .
HEALTH TECHNOLOGY ASSESSMENT, 2013, 17 (40) :1-+
[6]   Partial coherence interferometry: A novel approach to biometry in cataract surgery [J].
Drexler, W ;
Findl, O ;
Menapace, R ;
Rainer, G ;
Vass, C ;
Hitzenberger, CK ;
Fercher, AF .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1998, 126 (04) :524-534
[7]   Trim and fill: A simple funnel-plot-based method of testing and adjusting for publication bias in meta-analysis [J].
Duval, S ;
Tweedie, R .
BIOMETRICS, 2000, 56 (02) :455-463
[8]   Comparison of Hoffer Q and Haigis Formulae for Intraocular Lens Power Calculation According to the Anterior Chamber Depth in Short Eyes [J].
Eom, Youngsub ;
Kang, Su-Yeon ;
Song, Jong Suk ;
Kim, Yong Yeon ;
Kim, Hyo Myung .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2014, 157 (04) :818-824
[9]  
Fedorov S N, 1967, Vestn Oftalmol, V80, P27
[10]   Refractive and visual outcome of hyperopic cataract cases operated on before and after implementation of the Holladay II formula [J].
Fenzl, RE ;
Gills, JP ;
Cherchio, M .
OPHTHALMOLOGY, 1998, 105 (09) :1759-1764