Fluid flow and mass transfer characteristics of enhanced CO2 capture in a minichannel reactor

被引:83
作者
Ganapathy, H. [1 ]
Shooshtari, A. [1 ]
Dessiatoun, S. [1 ]
Alshehhi, M. [2 ]
Ohadi, M. [1 ]
机构
[1] Univ Maryland, Dept Mech Engn, College Pk, MD 20742 USA
[2] Petr Inst, Dept Mech Engn, Abu Dhabi, U Arab Emirates
关键词
Carbon capture; CO2; Diethanolamine; Microreactor; Absorption; Microchannel; CARBON-DIOXIDE SEPARATION; 2-PHASE FLOW; PRESSURE-DROP; TAYLOR FLOW; HEAT-TRANSFER; ABSORPTION; GAS; ALKANOLAMINES; FUEL; MINI/MICROCHANNELS;
D O I
10.1016/j.apenergy.2013.12.047
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
CO2 absorption using amine solvents can be significantly enhanced by the use of microscale reactors having high surface area to volume ratio. The present paper reports an experimental investigation of the fluid flow and mass transfer characteristics during reactive gas-liquid absorption in a minichannel reactor. Absorption of CO2 mixed with N-2 into aqueous diethanolamine was studied in a channel having hydraulic diameter of 762 mu m and a circular cross-sectional geometry. High-speed imaging of the two-phase flow was conducted to visualize the flow regimes. Image-processing analysis of the acquired flow patterns was performed to determine the interfacial area. The performance of the reactor was studied with respect to the absorption efficiency, pressure drop, mass transfer coefficient, interfacial area, enhancement factor, and Sherwood number. Parametric studies investigating the effects of phase superficial velocity, liquid reactant concentration, and CO2 concentration in the gas phase were performed and are discussed. High levels of absorption efficiency, close to 100%, were observed under certain operating conditions. An empirical model for the Sherwood number was developed and compared against experimental data, The mass transfer coefficient was found to be higher at reduced channel lengths, which was attributed to improved utilization of the absorption capacity of the amine solution for a given reactor volume. The presently achieved values of mass transfer coefficient and specific interfacial area are between I and 4 orders of magnitude higher than those reported for most conventional absorption systems. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:43 / 56
页数:14
相关论文
共 83 条
[1]   Separation of CO2 from flue gas:: A review [J].
Aaron, D ;
Tsouris, C .
SEPARATION SCIENCE AND TECHNOLOGY, 2005, 40 (1-3) :321-348
[2]   Mass transport correlation for CO2 absorption in aqueous monoethanolamine in a continuous film contactor [J].
Akanksha ;
Pant, K. K. ;
Srivastava, V. K. .
CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 2008, 47 (05) :920-928
[3]   Colloidal processing and CO2 capture performance of sacrificially templated zeolite monoliths [J].
Akhtar, Farid ;
Andersson, Linnea ;
Keshavarzi, Neda ;
Bergstrom, Lennart .
APPLIED ENERGY, 2012, 97 :289-296
[4]  
Armand A.A., 1946, Izv. Vses. Teplotekh., V1, P16
[5]  
BLAUWHOFF PMM, 1984, CHEM ENG SCI, V39, P207, DOI 10.1016/0009-2509(84)80021-4
[6]  
Bounaceur R, 2006, ENERGY, V31, P2556, DOI 10.1016/j.energy.2005.10.038
[7]   PHYSICAL SOLUBILITY OF CARBON-DIOXIDE IN AQUEOUS ALKANOLAMINES VIA NITROUS-OXIDE ANALOGY [J].
BROWNING, GJ ;
WEILAND, RH .
JOURNAL OF CHEMICAL AND ENGINEERING DATA, 1994, 39 (04) :817-822
[8]  
Charpentier J.C., 1981, Adv. Chem. Eng., V11, P1, DOI [10.1016/S0065-2377(08)60025-3, DOI 10.1016/S0065-2377(08)60025-3, /10.1016/S0065-2377(08)60025-3]
[9]   Gas-Liquid Microreaction Technology: Recent Developments and Future Challenges [J].
Chen Guangwen ;
Yue Jun ;
Yuan Quan .
CHINESE JOURNAL OF CHEMICAL ENGINEERING, 2008, 16 (05) :663-669
[10]   High-Throughput Microporous Tube-in-Tube Microreactor as Novel Gas-Liquid Contactor: Mass Transfer Study [J].
Chen, Jian-Feng ;
Chen, Gui-Zi ;
Wang, Jie-Xin ;
Shao, Lei ;
Li, Peng-Fei .
AICHE JOURNAL, 2011, 57 (01) :239-249