Shoulder muscle force and electromyography activity during make versus break tests

被引:1
作者
Shah, Kshamata M. [1 ]
Madara, Kathleen C. [1 ,2 ]
Diehl, Ian [1 ]
Hyer, Michael [1 ]
Schur, Jacob [1 ]
McClure, Philip W. [1 ]
机构
[1] Arcadia Univ, Phys Therapy Dept, 450 S Easton Rd, Glenside, PA 19038 USA
[2] Moravian Coll, Phys Therapy Dept, 1200 Main St, Bethlehem, PA 18018 USA
关键词
Shoulder; Force; Isometric; Eccentric; EMG; HAND-HELD DYNAMOMETER; RELIABILITY; STRENGTH; CONTRACTIONS;
D O I
10.1016/j.clinbiomech.2020.105189
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: Shoulder muscle force is commonly assessed during clinical examination using both an isometric "make" test against a fixed resistance or a "break" test where the examiner exerts enough force to break the isometric contraction. The purpose of this study was to explain the difference in force produced during these two forms of testing. Methods: Data were collected on 25 subjects. Both shoulder external rotation and elevation force were measured over three trials, isometrically, for approximately 3 s, after which the examiner exerted enough force to move the arm. Surface EMG was recorded for the infraspinatus for external rotation and middle deltoid for elevation. Peak isometric and break forces, and normalized, averaged EMG data at peak isometric and break forces were compared with paired t-tests. Findings: External rotation peak break force was 46.9% (SD33.6, range - 3% to 108.6%) greater than isometric force (p < 0.01). EMG for the infraspinatus was 17.0% (20.8) greater at break (p < 0.01). For elevation, peak break force was 63% (73.1, range - 3.5 to 238.16%) greater than isometric force (p < 0.01). EMG for the middle deltoid was 11.1% (30.8) greater during peak break force (not significant). Interpretations: There is a difference in both force and muscle activity between "make" and "break" tests. Clinicians should use a consistent method when measuring force and a break test will provide the maximum force. The cause of greater force produced during a break test is likely attributable to the brief eccentric contraction rather than greater recruitment. Future analysis will include examining the differences in make and break forces based on activity levels.
引用
收藏
页数:5
相关论文
共 17 条
[1]   Decreased external rotation strength is a risk factor for overuse shoulder injury in youth elite handball athletes [J].
Achenbach, Leonard ;
Laver, Lior ;
Walter, Sven Stephan ;
Zeman, Florian ;
Kuhr, Matthias ;
Krutsch, Werner .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2020, 28 (04) :1202-1211
[2]   Efficacy of electromyographic biofeedback and electrical stimulation following arthroscopic partial meniscectomy: a randomized controlled trial [J].
Akkaya, Nuray ;
Ardic, Fusun ;
Ozgen, Merih ;
Akkaya, Semih ;
Sahin, Fusun ;
Kilic, Alper .
CLINICAL REHABILITATION, 2012, 26 (03) :224-236
[3]   Comparing surface and indwelling electromyographic signals of the supraspinatus and infraspinatus muscles during submaximal axial humeral rotation [J].
Allen, Tyler R. ;
Brookham, Rebecca L. ;
Cudlip, Alan C. ;
Dickerson, Clark R. .
JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2013, 23 (06) :1343-1349
[4]  
Beshay N., 2011, SHOULDER ELB, V3, P244, DOI DOI 10.1111/J.1758-5740.2011.00137.X
[5]   Eccentric contractions require unique activation strategies by the nervous system [J].
Enoka, RM .
JOURNAL OF APPLIED PHYSIOLOGY, 1996, 81 (06) :2339-2346
[6]  
FRIDEN J, 1992, MED SCI SPORT EXER, V24, P521
[7]   EMG differences between concentric and eccentric maximum voluntary contractions are evident prior to movement onset [J].
Grabiner, MD ;
Owings, TM .
EXPERIMENTAL BRAIN RESEARCH, 2002, 145 (04) :505-511
[8]   Hand-held dynamometry strength measures for internal and external rotation demonstrate superior reliability, lower minimal detectable change and higher correlation to isokinetic dynamometry than externally-fixed dynamometry of the shoulder [J].
Holt, K. L. ;
Raper, D. P. ;
Boettcher, C. E. ;
Waddington, G. S. ;
Drew, M. K. .
PHYSICAL THERAPY IN SPORT, 2016, 21 :75-81
[9]   Measuring Eccentric Strength of the Shoulder External Rotators Using a Handheld Dynamometer: Reliability and Validity [J].
Johansson, Fredrik R. ;
Skillgate, Eva ;
Lapauw, Mattis L. ;
Clijmans, Dorien ;
Deneulin, Valentijn P. ;
Palmans, Tanneke ;
Cools, Ann M. .
JOURNAL OF ATHLETIC TRAINING, 2015, 50 (07) :719-725
[10]   Biomechanical response of skeletal muscle to eccentric contractions [J].
Lieber, Richard L. .
JOURNAL OF SPORT AND HEALTH SCIENCE, 2018, 7 (03) :294-309