Air leaking through the mouth during nocturnal nasal ventilation: Effect on sleep quality

被引:90
作者
Meyer, TJ
Pressman, MR
Benditt, J
McCool, FD
Millman, RP
Natarajan, R
Hill, NS
机构
[1] LANKENAU HOSP & MED RES CTR,DIV PULM & CRIT CARE MED,WYNNEWOOD,PA
[2] LANKENAU HOSP & MED RES CTR,SLEEP DISORDERS CTR,WYNNEWOOD,PA
[3] UNIV WASHINGTON,DIV PULM & CRIT CARE MED,SEATTLE,WA 98195
[4] BROWN UNIV,DEPT PULM & CRIT CARE MED,PROVIDENCE,RI 02912
[5] BROWN UNIV,CTR STAT SCI,PROVIDENCE,RI 02912
关键词
chronic respiratory failure; mechanical ventilation; nasal ventilation;
D O I
10.1093/sleep/20.7.561
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Air leaking through the mouth has been reported in kyphoscoliotic patients receiving nasal ventilation via volume-limited ventilators. This study accessed the frequency of occurrence and effect on sleep quality of air leaking through the mouth during nocturnal nasal ventilation in patients with chest wall and neuromuscular disease using pressure-limited ventilation. Overnight and daytime polysomnography was performed in six stable experienced users of nocturnal nasal noninvasive positive-pressure ventilation (NPPV) who had chronic respiratory failure due to neuromuscular disease or chest wall deformity. All patients used the BiPAP S/T-D ventilatory support system (Respironics, Inc., Murrysville, PA). Measures included sleep scoring, leak quantitation, diaphragm and submental electromyograms (EMGs), and tidal and leak volumes. All patients had air leaking through the mouth for the majority of sleep. Sleep quality was diminished because of poor sleep efficiency and reduced percentages of slow-wave and rapid eye movement (REM) sleep. Air leaking through the mouth was associated with frequent arousals during stages 1 and 2 and REM sleep that contributed to sleep fragmentation, but arousals were infrequent during slow-wave sleep. Despite prevalent leaking, oxygenation was well maintained in all but one patient. Patients used a combination of passive and active mechanisms to control air leaking. Although nasal ventilation improves nocturnal hypoventilation and symptoms in patients with restrictive thoracic disorders, air leaking through the mouth is very common during use. The leaking is associated with frequent arousals during lighter stages of sleep that interfere with progression to deeper stages, compromising sleep quality. Portable pressure-limited ventilators compensate for leaks, maintaining ventilation and oxygenation, but further studies are needed to determine which interfaces and ventilator techniques best control air leaking and optimize sleep quality.
引用
收藏
页码:561 / 569
页数:9
相关论文
共 15 条
[1]   SLEEP FRAGMENTATION IN KYPHOSCOLIOTIC INDIVIDUALS WITH ALVEOLAR HYPOVENTILATION TREATED BY NIPPV [J].
BACH, JR ;
ROBERT, D ;
LEGER, P ;
LANGEVIN, B .
CHEST, 1995, 107 (06) :1552-1558
[2]   MANAGEMENT OF CHRONIC ALVEOLAR HYPOVENTILATION BY NASAL VENTILATION [J].
BACH, JR ;
ALBA, AS .
CHEST, 1990, 97 (01) :52-57
[3]   MOUTH INTERMITTENT POSITIVE PRESSURE VENTILATION IN THE MANAGEMENT OF POSTPOLIO RESPIRATORY INSUFFICIENCY [J].
BACH, JR ;
ALBA, AS ;
BOHATIUK, G ;
SAPORITO, L ;
LEE, M .
CHEST, 1987, 91 (06) :859-864
[4]   VENTILATION AND AROUSAL RESPONSES TO HYPERCAPNIA IN NORMAL SLEEPING HUMANS [J].
BERTHONJONES, M ;
SULLIVAN, CE .
JOURNAL OF APPLIED PHYSIOLOGY, 1984, 57 (01) :59-67
[5]   CONTROL OF NOCTURNAL HYPOVENTILATION BY NASAL INTERMITTENT POSITIVE PRESSURE VENTILATION [J].
CARROLL, N ;
BRANTHWAITE, MA .
THORAX, 1988, 43 (05) :349-353
[6]   NONINVASIVE VENTILATORY SUPPORT DURING SLEEP IMPROVES RESPIRATORY-FAILURE IN KYPHOSCOLIOSIS [J].
ELLIS, ER ;
GRUNSTEIN, RR ;
CHAN, S ;
BYE, PTP ;
SULLIVAN, CE .
CHEST, 1988, 94 (04) :811-815
[7]   NIGHT-TIME NASAL VENTILATION IN NEUROMUSCULAR DISEASE [J].
HECKMATT, JZ ;
LOH, L ;
DUBOWITZ, V .
LANCET, 1990, 335 (8689) :579-582
[8]   EFFICACY OF NOCTURNAL NASAL VENTILATION IN PATIENTS WITH RESTRICTIVE THORACIC DISEASE [J].
HILL, NS ;
EVELOFF, SE ;
CARLISLE, CC ;
GOFF, SG .
AMERICAN REVIEW OF RESPIRATORY DISEASE, 1992, 145 (02) :365-371
[9]   NASAL INTERMITTENT POSITIVE PRESSURE VENTILATION - ANALYSIS OF ITS WITHDRAWAL [J].
JIMENEZ, JFM ;
ESCUIN, JSDC ;
VICENTE, CD ;
VALLE, MH ;
OTERO, FF .
CHEST, 1995, 107 (02) :382-388
[10]  
LEGER P, 1989, Respiratory Care, V34, P73