Volumetric High-Resolution X-Ray Phase-Contrast Virtual Histology of Breast Specimens With a Compact Laboratory System

被引:22
作者
Massimi, Lorenzo [1 ]
Suaris, Tamara [2 ]
Hagen, Charlotte K. [1 ]
Endrizzi, Marco [1 ]
Munro, Peter R. T. [1 ]
Havariyoun, Glafkos [1 ]
Hawker, P. M. Sam [3 ]
Smit, Bennie [3 ]
Astolfo, Alberto [3 ]
Larkin, Oliver J. [3 ]
Waltham, Richard M. [3 ]
Shah, Zoheb [4 ]
Duffy, Stephen W. [4 ]
Nelan, Rachel L. [4 ]
Peel, Anthony [2 ]
Jones, J. Louise [2 ,4 ]
Haig, Ian G. [3 ]
Bate, David [3 ]
Olivo, Alessandro [1 ]
机构
[1] UCL, Dept Med Phys & Biomed Engn, London WC1E 6BT, England
[2] Barts Hlth NHS Trust, St Bartholomews Hosp, London E1 1BB, England
[3] Nikon X Tek Syst, Tring Business Ctr, Tring HP23 4JX, Herts, England
[4] Queen Mary Univ London, Barts & London Sch Med & Dent, London E1 4NS, England
基金
英国工程与自然科学研究理事会; 英国惠康基金;
关键词
Histopathology; Spatial resolution; Imaging; Image edge detection; X-ray imaging; Surgery; Computed tomography; Breast conserving surgery; multi-resolution imaging; X-ray phase contrast; SPATIAL-RESOLUTION; EXCISION; CANCER; TISSUE;
D O I
10.1109/TMI.2021.3137964
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
The assessment of margin involvement is a fundamental task in breast conserving surgery to prevent recurrences and reoperations. It is usually performed through histology, which makes the process time consuming and can prevent the complete volumetric analysis of large specimens. X-ray phase contrast tomography combines high resolution, sufficient penetration depth and high soft tissue contrast, and can therefore provide a potential solution to this problem. In this work, we used a high-resolution implementation of the edge illumination X-ray phase contrast tomography based on "pixel-skipping" X-ray masks and sample dithering, to provide high definition virtual slices of breast specimens. The scanner was originally designed for intra-operative applications in which short scanning times were prioritised over spatial resolution; however, thanks to the versatility of edge illumination, high-resolution capabilities can be obtained with the same system simply by swapping x-ray masks without this imposing a reduction in the available field of view. This makes possible an improved visibility of fine tissue strands, enabling a direct comparison of selected CT slices with histology, and providing a tool to identify suspect features in large specimens before slicing. Combined with our previous results on fast specimen scanning, this works paves the way for the design of a multi-resolution EI scanner providing intra-operative capabilities as well as serving as a digital pathology system.
引用
收藏
页码:1188 / 1195
页数:8
相关论文
共 41 条
[1]   X-ray based virtual histology allows guided sectioning of heavy ion stained murine lungs for histological analysis [J].
Albers, Jonas ;
Markus, M. Andrea ;
Alves, Frauke ;
Dullin, Christian .
SCIENTIFIC REPORTS, 2018, 8
[2]  
[Anonymous], 2000, Norma ISO 9001:2000
[3]  
Arboleda C, 2020, EUR RADIOL, V30, P1419, DOI 10.1007/s00330-019-06362-x
[4]   Establishing sample-preparation protocols for X-ray phase-contrast CT of rodent spinal cords: Aldehyde fixations and osmium impregnation [J].
Barbone, Giacomo E. ;
Bravin, Alberto ;
Mittone, Alberto ;
Kraiger, Markus J. ;
de Angelis, Martin Hrabe ;
Bossi, Mario ;
Ballarini, Elisa ;
Rodriguez-Menendez, Virginia ;
Ceresa, Cecilia ;
Cavaletti, Guido ;
Coan, Paola .
JOURNAL OF NEUROSCIENCE METHODS, 2020, 339
[5]   Spectrally encoded confocal microscopy for diagnosing breast cancer in excision and margin specimens [J].
Brachtel, Elena F. ;
Johnson, Nicole B. ;
Huck, Amelia E. ;
Rice-Stitt, Travis L. ;
Vangel, Mark G. ;
Smith, Barbara L. ;
Tearney, Guillermo J. ;
Kang, Dongkyun .
LABORATORY INVESTIGATION, 2016, 96 (04) :459-467
[6]   Monochromatic Propagation-Based Phase-Contrast Microscale Computed-Tomography System with a Rotating-Anode Source [J].
Brombal, L. ;
Kallon, G. ;
Jiang, J. ;
Savvidis, S. ;
De Coppi, P. ;
Urbani, L. ;
Forty, E. J. ;
Chambers, R. C. ;
Longo, R. ;
Olivo, A. ;
Endrizzi, M. .
PHYSICAL REVIEW APPLIED, 2019, 11 (03)
[7]   Image quality comparison between a phase-contrast synchrotron radiation breast CT and a clinical breast CT: a phantom based study [J].
Brombal, Luca ;
Arfelli, Fulvia ;
Delogu, Pasquale ;
Donato, Sandro ;
Mettivier, Giovanni ;
Michielsen, Koen ;
Oliva, Piernicola ;
Taibi, Angelo ;
Sechopoulos, Ioannis ;
Longo, Renata ;
Fedon, Christian .
SCIENTIFIC REPORTS, 2019, 9 (1)
[8]  
cancer research uk uk, BREAST CANC STAT
[9]   The role of Micro-CT in imaging breast cancer specimens [J].
DiCorpo, Daniel ;
Tiwari, Ankur ;
Tang, Rong ;
Griffin, Molly ;
Aftreth, Owen ;
Bautista, Pinky ;
Hughes, Kevin ;
Gershenfeld, Neil ;
Michaelson, James .
BREAST CANCER RESEARCH AND TREATMENT, 2020, 180 (02) :343-357
[10]   Single-Shot X-Ray Phase-Contrast Computed Tomography with Nonmicrofocal Laboratory Sources [J].
Diemoz, P. C. ;
Hagen, C. K. ;
Endrizzi, M. ;
Minuti, M. ;
Bellazzini, R. ;
Urbani, L. ;
De Coppi, P. ;
Olivo, A. .
PHYSICAL REVIEW APPLIED, 2017, 7 (04)