Influence of Harmonic AC Voltage on Surface Discharge Formation in Transformer Insulation

被引:19
|
作者
Sarathi, R. [1 ]
Sheema, I. P. Merin [1 ]
Rajan, J. Sundara [2 ]
Danikas, M. G. [3 ]
机构
[1] Indian Inst Technol, Dept Elect Engn, Madras 600036, Tamil Nadu, India
[2] Cent Power Res Inst, Bangalore 560080, Karnataka, India
[3] Democritus Univ Thrace, Dept Elect & Comp Engn, GR-67100 Xanthi, Greece
关键词
Surface discharge; Harmonics; PRPD; UHF; THD; Partial discharges; CHARGE ACCUMULATION; OIL; PRESSBOARD; DISTORTION; TRACKING; GAPS; UHF;
D O I
10.1109/TDEI.2014.004448
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The Ultra High Frequency (UHF) signal radiated during the surface discharge process under harmonic AC voltages with different Total Harmonic Distortion (THD) shows a dominant frequency at 0.8 GHz. The surface discharge inception voltage decreases with an increase in harmonics and THD as observed in the present work. The peak factor of the harmonic voltage and the surface discharge inception factor show inverse relationship. The rise time of injected current pulse due to surface discharges measured using High Frequency Current Transformer (HFCT) is about 600 ps and 900 ps for the positive and negative current signal, respectively. Cumulative energy spectra and Ternary plot confirms that UHF signal generated due to surface discharge process does not significantly vary under harmonic AC voltage with different THD's. The magnitude of UHF signal formed due to surface discharge under 50 Hz AC voltage is higher than that formed under the harmonic AC voltage. Surface charge measurement after corona charging process with the oil impregnated pressboard material indicates that the amount of charge deposited is high with the specimen damaged under harmonic AC voltage. Degraded zone of oil impregnated pressboard insulation due to surface discharges was analyzed using Attenuated Total Reflectance Fourier Transform Infra-red (ATR-FTIR) spectroscopy. Phase resolved partial discharge (PRPD) studies indicate that surface discharge activity predominates when the rate of rise of voltage is high.
引用
收藏
页码:2383 / 2393
页数:11
相关论文
共 50 条
  • [1] Understanding Surface Discharge Activity in Copper Sulphide Diffused Transformer Insulation under Harmonic AC Voltages
    Sarathi, R.
    Sheema, I. P. Merin
    2013 2ND INTERNATIONAL CONFERENCE ON ELECTRIC POWER EQUIPMENT - SWITCHING TECHNOLOGY (ICEPE-ST), 2013,
  • [2] Influence of surface charge on DC or AC partial discharge inception voltage in insulation-air gap composite system
    Kawashima, Tomohiro
    Inoue, Kaito
    Yokomi, Kazuya
    Murakami, Yoshinobu
    Ishida, Takahiro
    Nagao, Masayuki
    IEEJ Transactions on Fundamentals and Materials, 2015, 135 (04) : 235 - 240
  • [3] The phenomena and characteristics of oil-paper insulation surface discharge under AC and DC voltage
    Qi, Bo
    Wei, Zhen
    Li, Chengrong
    Yuan, Qing
    Gao, Yi
    Zhang, Xiaohan
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2016, 31 (10): : 59 - 67
  • [4] Influence of Nonstandard Voltage Stresses on Transformer Insulation Paper
    Knenicky, Martin
    Prochazka, Radek
    Sefl, Ondrej
    2017 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENON (CEIDP), 2017, : 700 - 703
  • [5] THE INFLUENCE OF SQUARE VOLTAGE WAVEFORMS ON TRANSFORMER INSULATION BREAK DOWN VOLTAGE
    Koltunowicz, Tomasz
    Cavallini, Andrea
    Djairam, Dhiradj
    Montanari, Gian Carlo
    Smit, Johan
    2011 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, VOLS 1 AND 2, 2011, : 48 - 51
  • [6] Partial Discharge Inception Voltage in DC insulation systems: a comparison with AC voltage supply
    Seri, Paolo
    Cirioni, Leonardo
    Naderiallaf, Hadi
    Montanari, Gian Carlo
    Hebner, Robert
    Gattozzi, Angelo
    Feng, Xianyong
    2019 IEEE ELECTRICAL INSULATION CONFERENCE (EIC), 2019, : 176 - 179
  • [7] The Effect of Harmonic Distortion Voltage to Partial Discharge Characteristics in Epoxy Insulation
    Widyanto, Aji Nur
    Hirsch, Holger
    PROCEEDINGS OF THE 21ST INTERNATIONAL SYMPOSIUM ON HIGH VOLTAGE ENGINEERING, VOL 2, 2020, 599 : 877 - 884
  • [8] Breakdown Characteristics of Converter Transformer Insulation under Composite AC and DC Voltage
    Wang, Yonghong
    Wei, Xinlao
    Chen, Qingguo
    Huang, Yongrui
    Nie, Hongyan
    ICPADM 2009: PROCEEDINGS OF THE 9TH INTERNATIONAL CONFERENCE ON PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, VOLS 1-3, 2009, : 634 - 637
  • [9] Characteristics of the surface discharge process in oil-paper insulation under combined AC-DC voltage
    Jin, Fubao
    Zhou, Yuanxiang
    Liu, Zehong
    Huang, Meng
    Lu, Licheng
    Sha, Yanchao
    Gaodianya Jishu/High Voltage Engineering, 2015, 41 (06): : 1965 - 1973
  • [10] Partial discharge of oil-paper insulation under DC voltage superimposed AC voltage
    Sun Zhenquan
    Zhao Xuefeng
    Li Jisheng
    Gu Chaomin
    Li Yanming
    PRZEGLAD ELEKTROTECHNICZNY, 2010, 86 (08): : 312 - 318