Respiration-gated fast-rescanning carbon-ion radiotherapy

被引:20
作者
Ebner, Daniel K. [1 ,2 ]
Tsuji, Hiroshi [1 ]
Yasuda, Shigeo [1 ]
Yamamoto, Naoyoshi [1 ]
Mori, Shinichiro [1 ]
Kamada, Tadashi [1 ]
机构
[1] Natl Inst Quantum & Radiol Sci & Technol, Hosp Natl Inst Radiol Sci, Chiba, Japan
[2] Brown Univ, Alpert Med Sch, Providence, RI 02912 USA
关键词
carbon-ion radiotherapy; scanning method; clinical trial; respiration gating; MOVING TARGET IRRADIATION; PARTICLE THERAPY; DESIGN; MOTION; SYSTEM;
D O I
10.1093/jjco/hyw144
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Phase-controlled rescanning of the carbon-ion beam offers fast and precise dose application with decreased irradiation of normal tissue. However, organ movement with respiration remains a unique challenge. Technological development has enabled the simultaneous application of beam-energy-modulated markerless phase-controlled rescanning with respiration gating, allowing scanning treatment of respiration-mobile tumors with carbon. A total of 10 patients with tumors in the liver or lung were treated in a feasibility study at our facility using this combination. At a median of 10.5 months, follow-up examination including computed tomography/magnetic resonance imaging revealed no grade 2+ acute adverse effects with this new therapy. Two patients with complex disease experienced local recurrence, which may be improved with increased dose delivery. One patient died of unrelated causes. All other patients are alive with good control at the time of writing. Though long-term observation is pending, these are promising initial results for use of the carbon-beam phase-controlled rescanning method in respiration-mobile disease.
引用
收藏
页码:80 / 83
页数:4
相关论文
共 17 条
[1]  
[Anonymous], 2014, CARBON ION RADIOTHER, DOI [10.1007/978-4-431-54457-9, DOI 10.1007/978-4-431-54457-9]
[2]   Treatment with heavy charged particles: Systematic review of clinical data and current clinical (comparative) trials [J].
Combs, Stephanie E. ;
Debus, Juergen .
ACTA ONCOLOGICA, 2013, 52 (07) :1272-1286
[3]   Design study of a raster scanning system for moving target irradiation in heavy-ion radiotherapy [J].
Furukawa, Takuji ;
Inaniwa, Taku ;
Sato, Shinji ;
Tomitani, Takehiro ;
Minohara, Shinichi ;
Noda, Koji ;
Kanai, Tatsuaki .
MEDICAL PHYSICS, 2007, 34 (03) :1085-1097
[4]   Moving target irradiation with fast rescanning and gating in particle therapy [J].
Furukawa, Takuji ;
Inaniwa, Taku ;
Sato, Shinji ;
Shirai, Toshiyuki ;
Mori, Shinichiro ;
Takeshita, Eri ;
Mizushima, Kota ;
Himukai, Takeshi ;
Noda, Koji .
MEDICAL PHYSICS, 2010, 37 (09) :4874-4879
[5]   Carbon-Ion Therapy Applied in Raster Scanning Technique for Hepatocellular Carcinoma-First Results [J].
Habermehl, D. ;
Herfarth, K. ;
Ganten, T. ;
Ganten, M. ;
Parodi, K. ;
Wetzel, T. ;
Haberer, T. ;
Jaeckel, O. ;
Debus, J. ;
Combs, S. E. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 84 (03) :S845-S845
[6]   Hypofractionated carbon ion therapy delivered with scanned ion beams for patients with hepatocellular carcinoma - feasibility and clinical response [J].
Habermehl, Daniel ;
Debus, Juergen ;
Ganten, Tom ;
Ganten, Maria-Katharina ;
Bauer, Julia ;
Brecht, Ingo C. ;
Brons, Stephan ;
Haberer, Thomas ;
Haertig, Martin ;
Jaekel, Oliver ;
Parodi, Katia ;
Welzel, Thomas ;
Combs, Stephanie E. .
RADIATION ONCOLOGY, 2013, 8
[7]   Reformulation of a clinical-dose system for carbon-ion radiotherapy treatment planning at the National Institute of Radiological Sciences, Japan [J].
Inaniwa, Taku ;
Kanematsu, Nobuyuki ;
Matsufuji, Naruhiro ;
Kanai, Tatsuaki ;
Shirai, Toshiyuki ;
Noda, Koji ;
Tsuji, Hiroshi ;
Kamada, Tadashi ;
Tsujii, Hirohiko .
PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (08) :3271-3286
[8]   Implementation of a target volume design function for intrafractional range variation in a particle beam treatment planning system [J].
Mori, S. ;
Inaniwa, T. ;
Miki, K. ;
Shirai, T. ;
Noda, K. .
BRITISH JOURNAL OF RADIOLOGY, 2014, 87 (1043)
[9]   Real-time image-processing algorithm for markerless tumour tracking using X-ray fluoroscopic imaging [J].
Mori, S. .
BRITISH JOURNAL OF RADIOLOGY, 2014, 87 (1037)
[10]   Carbon-Ion Pencil Beam Scanning Treatment With Gated Markerless Tumor Tracking: An Analysis of Positional Accuracy [J].
Mori, Shinichiro ;
Karube, Masataka ;
Shirai, Toshiyuki ;
Tajiri, Minoru ;
Takekoshi, Takuro ;
Miki, Kentaro ;
Shiraishi, Yurika ;
Tanimoto, Katsuyuki ;
Shibayama, Kouichi ;
Yasuda, Shigeo ;
Yamamoto, Naoyoshi ;
Yamada, Shigeru ;
Tsuji, Hiroshi ;
Noda, Koji ;
Kamada, Tadashi .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 95 (01) :258-266