Optimal calibration marker mesh for 2D X-ray sensors in 3D reconstruction

被引:2
|
作者
Desbat, L [1 ]
Mennessier, C [1 ]
Champleboux, G [1 ]
机构
[1] Univ Grenoble 1, Fac Med, CNRS, UMR 5525,IAB,TIMC,IMAG, F-38706 La Tronche, France
关键词
interventional imaging; X-ray; image intensifier calibration; calibration grid without information lost; efficient sampling of the X-ray transform; fast and efficient Fourier interpolation;
D O I
10.1016/S1631-0691(02)01445-2
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Image intensifiers suffer from distortions due to magnetic fields. In order to use this X-ray projections images for computer-assisted medical interventions, image intensifiers need to be calibrated. Opaque markers are often used for the correction of the image distortion and the estimation of the acquisition geometry parameters. Information under the markers is then lost. In this work, we consider the calibration of image intensifiers in the framework of 3D reconstruction from several 2D X-ray projections. In this context, new schemes of marker distributions are proposed for 2D X-ray sensor calibration. They are based on efficient sampling conditions of the parallel-beam X-ray transform when the detector and source trajectory is restricted to a circle around the measured object. Efficient sampling are essentially subset of standard sampling in this situation. The idea is simply to exploit the data redundancy of standard sampling and to replace some holes of efficient schemes by markers. Optimal location of markers in the sparse efficient sampling geometry can thus be found. In this case, the markers can stay on the sensor during the measurement with - theoretically - no loss of information (when the signal-to-noise ratio is large). Even if the theory is based on the parallel-beam X-ray transform, numerical experiments on both simulated and real data are shown in the case of weakly divergent beam geometry. We show that the 3D reconstruction from simulated data with interlaced markers is essentially the same as those obtained from data with no marker. We show that efficient Fourier interpolation formulas based on optimal sparse sampling schemes can be used to recover the information hidden by the markers. (C) 2002 Academie des sciences/Editions scientifiques et medicales Elsevier SAS.
引用
收藏
页码:431 / 438
页数:8
相关论文
共 50 条
  • [21] An implementation of uniform and simultaneous ART for 3D volume reconstruction in X-ray imaging system
    Roh, YJ
    Park, WS
    Cho, HS
    Jeon, HJ
    OPTOMECHATRONIC SYSTEMS III, 2002, 4902 : 576 - 587
  • [22] The geometric modeling for 3D information of X-ray inspection
    Lee, Heung-Ho
    Lee, Seung-Min
    Transactions of the Korean Institute of Electrical Engineers, 2013, 62 (08) : 1151 - 1156
  • [23] Resolving power of 3D x-ray microtomography systems
    Seifert, A
    Flynn, MJ
    MEDICAL IMAGING 2002: PHYSICS OF MEDICAL IMAGING, 2002, 4682 : 407 - 413
  • [24] 3D Coronary Vessel Tracking in X-Ray Projections
    Poulain, Emmanuelle
    Malandain, Gregoire
    Vaillant, Regis
    FUNCTIONAL IMAGING AND MODELLING OF THE HEART, 2017, 10263 : 204 - 215
  • [25] X2V: 3D Organ Volume Reconstruction From a Planar X-Ray Image With Neural Implicit Methods
    Guven, Gokce
    Ates, Hasan F.
    Ugurdag, H. Fatih
    IEEE ACCESS, 2024, 12 : 50898 - 50910
  • [26] Automatic fasciation detection in salad with 2D X-ray imaging
    Sherif, H.
    Charrier, A.
    Rasti, P.
    Guiloteau, E.
    Messaka, J.
    Rousseau, D.
    XXXI INTERNATIONAL HORTICULTURAL CONGRESS, IHC2022: III INTERNATIONAL SYMPOSIUM ON MECHANIZATION, PRECISION HORTICULTURE, AND ROBOTICS: PRECISION AND DIGITAL HORTICULTURE IN FIELD ENVIRONMENTS, 2023, 1360 : 225 - 228
  • [27] 3D/2D Registration with superabundant vessel reconstruction for cardiac resynchronization therapy
    Toth, Daniel
    Panayiotou, Maria
    Brost, Alexander
    Behar, Jonathan M.
    Rinaldi, Christopher A.
    Rhode, Kawal S.
    Mountney, Peter
    MEDICAL IMAGE ANALYSIS, 2017, 42 : 160 - 172
  • [28] A Robust Method for Real Time Intraoperative 2D and Preoperative 3D X-Ray Image Registration Based on an Enhanced Swin Transformer Framework
    Ye, Wentao
    Wu, Jianghong
    Zhang, Wei
    Sun, Liyang
    Dong, Xue
    Xu, Shuogui
    BIOENGINEERING-BASEL, 2025, 12 (02):
  • [29] X-Ray 3D Stereo Remote Sensing for Biomedical Application
    Miroshnychenko, S. I.
    Volkov, E. V.
    2014 IEEE MICROWAVES, RADAR AND REMOTE SENSING SYMPOSIUM (MRRS), 2014, : 99 - 102
  • [30] Use of X-ray microtomography for 3D imaging of internal structures
    Hain, Miroslav
    Bartl, Jan
    Sevcik, Robert
    Jacko, Vlado
    18TH CZECH-POLISH-SLOVAK OPTICAL CONFERENCE ON WAVE AND QUANTUM ASPECTS OF CONTEMPORARY OPTICS, 2012, 8697