Optimal calibration marker mesh for 2D X-ray sensors in 3D reconstruction

被引:2
|
作者
Desbat, L [1 ]
Mennessier, C [1 ]
Champleboux, G [1 ]
机构
[1] Univ Grenoble 1, Fac Med, CNRS, UMR 5525,IAB,TIMC,IMAG, F-38706 La Tronche, France
关键词
interventional imaging; X-ray; image intensifier calibration; calibration grid without information lost; efficient sampling of the X-ray transform; fast and efficient Fourier interpolation;
D O I
10.1016/S1631-0691(02)01445-2
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Image intensifiers suffer from distortions due to magnetic fields. In order to use this X-ray projections images for computer-assisted medical interventions, image intensifiers need to be calibrated. Opaque markers are often used for the correction of the image distortion and the estimation of the acquisition geometry parameters. Information under the markers is then lost. In this work, we consider the calibration of image intensifiers in the framework of 3D reconstruction from several 2D X-ray projections. In this context, new schemes of marker distributions are proposed for 2D X-ray sensor calibration. They are based on efficient sampling conditions of the parallel-beam X-ray transform when the detector and source trajectory is restricted to a circle around the measured object. Efficient sampling are essentially subset of standard sampling in this situation. The idea is simply to exploit the data redundancy of standard sampling and to replace some holes of efficient schemes by markers. Optimal location of markers in the sparse efficient sampling geometry can thus be found. In this case, the markers can stay on the sensor during the measurement with - theoretically - no loss of information (when the signal-to-noise ratio is large). Even if the theory is based on the parallel-beam X-ray transform, numerical experiments on both simulated and real data are shown in the case of weakly divergent beam geometry. We show that the 3D reconstruction from simulated data with interlaced markers is essentially the same as those obtained from data with no marker. We show that efficient Fourier interpolation formulas based on optimal sparse sampling schemes can be used to recover the information hidden by the markers. (C) 2002 Academie des sciences/Editions scientifiques et medicales Elsevier SAS.
引用
收藏
页码:431 / 438
页数:8
相关论文
共 50 条
  • [1] Optimal 3D surface reconstruction from a small number of conventional 2D X-ray images
    Prakoonwit, Simant
    Benjamin, Ralph
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2007, 15 (04) : 197 - 222
  • [2] 3D Reconstruction of a Femur Shaft using a Model and Two 2D X-ray Images
    Wei Wei
    Wang Guorong
    Chen Hua
    ICCSSE 2009: PROCEEDINGS OF 2009 4TH INTERNATIONAL CONFERENCE ON COMPUTER SCIENCE & EDUCATION, 2009, : 720 - +
  • [3] 3D x-ray reconstruction using lightfield imaging
    Saha, Sajib
    Tahtali, Murat
    Lambert, Andrew
    Pickering, Mark
    ADVANCES IN COMPUTATIONAL METHODS FOR X-RAY OPTICS III, 2014, 9209
  • [4] 3D measurements in conventional X-ray imaging with RGB-D sensors
    Albiol, Francisco
    Corbi, Alberto
    Albiol, Alberto
    MEDICAL ENGINEERING & PHYSICS, 2017, 42 : 73 - 79
  • [5] A systematic review of the clinical effectiveness of EOS 2D/3D X-ray imaging system
    Ros Wade
    Huiqin Yang
    Claire McKenna
    Rita Faria
    Nigel Gummerson
    Nerys Woolacott
    European Spine Journal, 2013, 22 : 296 - 304
  • [6] A systematic review of the clinical effectiveness of EOS 2D/3D X-ray imaging system
    Wade, Ros
    Yang, Huiqin
    McKenna, Claire
    Faria, Rita
    Gummerson, Nigel
    Woolacott, Nerys
    EUROPEAN SPINE JOURNAL, 2013, 22 (02) : 296 - 304
  • [7] 3D Image Reconstruction from X-Ray Measurements with Overlap
    Klodt, Maria
    Hauser, Raphael
    COMPUTER VISION - ECCV 2016, PT VI, 2016, 9910 : 19 - 33
  • [8] A Hidden Markov Model for 3D Catheter Tip Tracking With 2D X-ray Catheterization Sequence and 3D Rotational Angiography
    Ambrosini, Pierre
    Smal, Ihor
    Ruijters, Daniel
    Niessen, Wiro J.
    Moelker, Adriaan
    Van Walsum, Theo
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2017, 36 (03) : 757 - 768
  • [9] WHAT 2D AND 3D (CT) X-RAY INSPECTION NOW PROVIDES FOR ELECTRONICS IN AUTOMOTIVE ENVIRONMENTS
    Bernard, David
    Bryant, Keith
    2018 INTERNATIONAL CONFERENCE ON ELECTRONICS PACKAGING AND IMAPS ALL ASIA CONFERENCE (ICEP-IAAC), 2018, : G1 - G5
  • [10] Transgraph: interactive intensity-based 2D/3D registration of X-ray and CT data
    LaRose, D
    Bayouth, J
    Kanade, T
    MEDICAL IMAGING 2000: IMAGE PROCESSING, PTS 1 AND 2, 2000, 3979 : 385 - 396