Time-efficient determination of spin compartments by time-encoded pCASL T2-relaxation-under-spin-tagging and its application in hemodynamic characterization of the cerebral border zones

被引:26
作者
Schmid, Sophie [1 ]
Teeuwisse, Wouter M. [1 ,2 ]
Lu, Hanzhang [3 ]
van Osch, Matthias J. P. [1 ,2 ]
机构
[1] LUMC, Dept Radiol, CJ Gorter Ctr High Field MRI, NL-2333 AA Leiden, Netherlands
[2] Leiden Inst Brain & Cognit, Leiden, Netherlands
[3] Johns Hopkins Univ, Dept Radiol, Baltimore, MD USA
关键词
Arterial transit time; Border zone regions; Cerebral blood flow; Spin compartment; T-2; relaxation; Time-encoded arterial spin labeling MRI; TRANSIT-TIME; BLOOD-FLOW; CAROTID-ARTERY; PERFUSION; QUANTIFICATION; ACTIVATION; MODEL; PET;
D O I
10.1016/j.neuroimage.2015.08.025
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Information on water-transport across the blood-brain barrier can be determined from the T-2 of the arterial spin labeling (ASL) signal. However, the current approach of using separate acquisitions of multiple inversion times is too time-consuming for clinical (research) applications. The aim of this study was to improve the time-efficiency of this method by combining it with time-encoded pseudo-continuous ASL (te-pCASL). Furthermore, the hemodynamic properties of the border zone regions in the brains of healthy, young volunteers were characterized as an example application. The use of te-pCASL instead of multi-TI pCASL significantly reduced the total scan duration, while providing a higher temporal resolution. A significantly lower cerebral blood flow (CBF) was found in the border zone regions compared with the central regions in both the posterior and the middle cerebral artery (MCA) flow territory. The arterial transit time (ATT) was almost two times longer in the border zone regions than in the central regions (p < 0.05), with an average delay in ATT of 382 ms in the posterior and 539 ms in the MCA flow territory. When corrected for the ATT, the change in T-2 over time was not significantly different for the border zones as compared to the central regions. In conclusion, te-pCASL-TRUST provided a time-efficient method to distinguish spin compartments based on their T-2. The ATT in the border zone is significantly longer than in the central region. However, the exchange of the label from the arterial to the tissue compartment appears to be at a similar rate. (C) 2015 Elsevier Inc. All rights reserved.
引用
收藏
页码:72 / 79
页数:8
相关论文
共 34 条
[1]   Reduced transit-time sensitivity in noninvasive magnetic resonance imaging of human cerebral blood flow [J].
Alsop, DC ;
Detre, JA .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1996, 16 (06) :1236-1249
[2]   Improved coronary artery definition with T2-weighted, free-breathing, three-dimensional coronary MRA [J].
Botnar, RM ;
Stuber, M ;
Danias, PG ;
Kissinger, KV ;
Manning, WJ .
CIRCULATION, 1999, 99 (24) :3139-3148
[3]   CORONARY ANGIOGRAPHY WITH MAGNETIZATION-PREPARED T-2 CONTRAST [J].
BRITTAIN, JH ;
HU, BS ;
WRIGHT, GA ;
MEYER, CH ;
MACOVSKI, A ;
NISHIMURA, DG .
MAGNETIC RESONANCE IN MEDICINE, 1995, 33 (05) :689-696
[4]   A general kinetic model for quantitative perfusion imaging with arterial spin labeling [J].
Buxton, RB ;
Frank, LR ;
Wong, EC ;
Siewert, B ;
Warach, S ;
Edelman, RR .
MAGNETIC RESONANCE IN MEDICINE, 1998, 40 (03) :383-396
[5]   Human Whole Blood T2 Relaxometry at 3 Tesla [J].
Chen, Jean J. ;
Pike, G. Bruce .
MAGNETIC RESONANCE IN MEDICINE, 2009, 61 (02) :249-254
[6]   Volumetric measurement of perfusion and arterial transit delay using hadamard encoded continuous arterial spin labeling [J].
Dai, Weiying ;
Shankaranarayanan, Ajit ;
Alsop, David C. .
MAGNETIC RESONANCE IN MEDICINE, 2013, 69 (04) :1014-1022
[7]   Severe hemodynamic impairment and border zone-region infarction [J].
Derdeyn, CP ;
Khosla, A ;
Videen, TO ;
Fritsch, SM ;
Carpenter, DL ;
Grubb, RL ;
Powers, WJ .
RADIOLOGY, 2001, 220 (01) :195-201
[8]   An account of the discrepancy between MRI and PET cerebral blood flow measures. A high-field MRI investigation [J].
Donahue, Manus J. ;
Lu, Hanzhang ;
Jones, Craig K. ;
Pekar, James J. ;
van Zijl, Peter C. M. .
NMR IN BIOMEDICINE, 2006, 19 (08) :1043-1054
[9]  
Garcia DM., 2005, Proc. 13'th ISMRM, P37
[10]  
Gonzalez-At JB, 2000, MAGNET RESON MED, V43, P739, DOI 10.1002/(SICI)1522-2594(200005)43:5<739::AID-MRM17>3.0.CO