Impact of Contrast Media Concentration on Low-Kilovolt Computed Tomography Angiography A Systematic Preclinical Approach

被引:23
作者
Fleischmann, Ulrike [1 ]
Pietsch, Hubertus [2 ]
Korporaal, Johannes G. [3 ]
Flohr, Thomas G. [3 ]
Uder, Michael [1 ,4 ]
Jost, Gregor [2 ]
Lell, Michael M. [5 ]
机构
[1] Friedrich Alexander Univ Erlangen Nuernberg FAU, Dept Radiol, Erlangen, Germany
[2] Bayer AG, MR & CT Contrast Media Res, Berlin, Germany
[3] Siemens Healthcare, Forchheim, Germany
[4] ISI, Erlangen, Germany
[5] Paracelsus Med Univ, Dept Radiol & Nucl Med, Nurnberg, Germany
关键词
computed tomography angiography; contrast media; iodine delivery rate; iodine concentration; low kilovolt; CORONARY CT ANGIOGRAPHY; DUAL-SOURCE CT; IMAGE QUALITY; TUBE-VOLTAGE; ITERATIVE RECONSTRUCTION; INTRAVASCULAR ENHANCEMENT; IODINE CONCENTRATION; DIAGNOSTIC-ACCURACY; INJECTION PROTOCOLS; MDCT ANGIOGRAPHY;
D O I
10.1097/RLI.0000000000000437
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: Low peak kilovoltage (kVp) protocols in computed tomography angiography (CTA) demand a review of contrast media (CM) administration practices. The aim of this study was to systematically evaluate different iodine concentrations of CM in a porcine model. Materials and Methods: Dynamic 70 kVp CTA was performed on 7 pigs using a third-generation dual-source CT system. Three CM injection protocols (A-C) with an identical total iodine dose and iodine delivery rate (150 mg I/kg, 12 s, 0.75 g I/s) differed in iodine concentration and flow rate (protocol A: 400 mg I/mL, 1.9 mL/s; B: 300 mg I/mL, 2.5 mL/s; C: 150 mg I/mL, 5 mL/s). All protocols were applied in a randomized order and compared intraindividually. Arterial enhancement at different locations in the pulmonary artery, the aorta, and aortic branches was measured over time. Time attenuation curves, peak enhancement, time to peak, and bolus tracking delay times needed for static CTA were calculated. The reproducibility of optimal parameters was tested in single-phase CTA. Results: The heart rates of the pigs were comparable for all protocols (P > 0.7). The injection pressure was significantly higher for protocol A (64 +/- 5 psi) and protocol C (55 +/- 3 psi) compared with protocol B (39 +/- 2 psi) (P < 0.001). Average arterial peak enhancement in the dynamic scans was 359 +/- 51 HU (protocol A), 382 +/- 36 HU (B), and 382 +/- 60 HU (C) (A compared with B and C: P < 0.01; B compared with C: P = 0.995). Time to peak enhancement decreased with increasing injection rate. The delay time for bolus tracking depended on the injection rate as well and was highest for protocol A (4.7 seconds) and lowest for protocol C (3.9 seconds) (P = 0.038). The peak enhancement values of the dynamic scans highly correlated with those of the single-phase CTA scans. Conclusions: In 70 kVp CTA, 300 mg I/mL iodine concentrations showed to be superior to high-concentration CM when keeping the iodine delivery rate constant. Besides, iodine concentrations as low as 150 mg I/mL can be administered without compromising vascular enhancement. This opens up new possibilities in CM administration.
引用
收藏
页码:264 / 270
页数:7
相关论文
共 45 条
[1]   SCCT guidelines for the performance and acquisition of coronary computed tomographic angiography: A report of the society of Cardiovascular Computed Tomography Guidelines Committee Endorsed by the North American Society for Cardiovascular Imaging (NASCI) [J].
Abbara, Suhny ;
Blanke, Philipp ;
Maroules, Christopher D. ;
Cheezum, Michael ;
Choi, Andrew D. ;
Han, B. Kelly ;
Marwan, Mohamed ;
Naoum, Chris ;
Norgaard, Bjarne L. ;
Rubinshtein, Ronen ;
Schoenhagen, Paul ;
Villines, Todd ;
Leipsic, Jonathon .
JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2016, 10 (06) :435-449
[2]   Comparative assessment of image quality for coronary CT angiography with iobitridol and two contrast agents with higher iodine concentrations: iopromide and iomeprol. A multicentre randomized double-blind trial [J].
Achenbach, Stephan ;
Paul, Jean-Francois ;
Laurent, Francois ;
Becker, Hans-Christoph ;
Rengo, Marco ;
Caudron, Jerome ;
Leschka, Sebastian ;
Vignaux, Olivier ;
Knobloch, Gesine ;
Benea, Giorgio ;
Schlosser, Thomas ;
Andreu, Jordi ;
Cabeza, Beatriz ;
Jacquier, Alexis ;
Souto, Miguel ;
Revel, Didier ;
Qanadli, Salah Dine ;
Cademartiri, Filippo .
EUROPEAN RADIOLOGY, 2017, 27 (02) :821-830
[3]   Randomized Comparison of 64-Slice Single- and Dual-Source Computed Tomography Coronary Angiography for the Detection of Coronary Artery Disease [J].
Achenbach, Stephan ;
Ropers, Ulrike ;
Kuettner, Axel ;
Anders, Katharina ;
Pflederer, Tobias ;
Komatsu, Sei ;
Bautz, Werner ;
Daniel, Werner G. ;
Ropers, Dieter .
JACC-CARDIOVASCULAR IMAGING, 2008, 1 (02) :177-186
[4]  
[Anonymous], 2014, ACR NASI SIR SPR PRA
[5]   Revival of monophasic contrast injection protocols: superiority of a monophasic injection protocol compared to a biphasic injection protocol in high-pitch CT angiography [J].
Apitzsch, Jonas ;
Jost, Gregor ;
Bonifer, Elisabeth ;
Keulers, Annika ;
Pietsch, Hubertus ;
Mahnken, Andreas Horst .
ACTA RADIOLOGICA, 2016, 57 (10) :1210-1216
[6]   Identification of the Iodine Concentration That Yields the Highest Intravascular Enhancement in MDCT Angiography [J].
Behrendt, Florian F. ;
Pietsch, Hubertus ;
Jost, Gregor ;
Palmowski, Moritz ;
Guenther, Rolf W. ;
Mahnken, Andreas H. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2013, 200 (05) :1151-1156
[7]   Intra-individual comparison of different contrast media concentrations (300 mg, 370 mg and 400 mg iodine) in MDCT [J].
Behrendt, Florian F. ;
Pietsch, Hubertus ;
Jost, Gregor ;
Sieber, Martin A. ;
Keil, Sebastian ;
Plumhans, Cedric ;
Seidensticker, Peter ;
Guenther, Rolf W. ;
Mahnken, Andreas H. .
EUROPEAN RADIOLOGY, 2010, 20 (07) :1644-1650
[8]   Image Quality of Low-Energy Pulmonary CT Angiography: Comparison With Standard CT [J].
Bogot, Naama R. ;
Fingerle, Alexander ;
Shaham, Dorith ;
Nissenbaum, Izhak ;
Sosna, Jacob .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 197 (02) :W273-W278
[9]   Low-tube-voltage (80 kVp) CT aortography using 320-row volume CT with adaptive iterative reconstruction: lower contrast medium and radiation dose [J].
Chen, Chien-Ming ;
Chu, Sung-Yu ;
Hsu, Ming-Yi ;
Liao, Ying-Lan ;
Tsai, Hui-Yu .
EUROPEAN RADIOLOGY, 2014, 24 (02) :460-468
[10]   CT Angiography of the Renal Arteries: Comparison of Lower-Tube-Voltage CTA With Moderate-Concentration Iodinated Contrast Material and Conventional CTA [J].
Cho, Eun-Suk ;
Yu, Jeong-Sik ;
Ahn, Jhii-Hyun ;
Kim, Joo Hee ;
Chung, Jae-Joon ;
Lee, Hyeon-Kyeong ;
Lee, Kyung Hee .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 199 (01) :96-102