High performance liquid chromatography tandem mass spectrometry assay for the determination of cobinamide in pig plasma

被引:3
作者
McCracken, Brent A. [1 ]
Brittain, Matthew K. [1 ]
机构
[1] Battelle Mem Inst, West Jefferson, OH 43162 USA
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2015年 / 1006卷
关键词
Cobinamide; Dicyanocobinamide; Nitrocobinamide; Potassium cyanide; Yorkshire pig plasma; Liquid chromatography-tandem mass spectrometry; COBALAMIN PRECURSOR COBINAMIDE; CYANIDE;
D O I
10.1016/j.jchromb.2015.10.008
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Liquid chromatography-tandem mass spectrometry (LC-MS/MS) has been widely utilized for the analysis of compounds in biological matrices due to its selectivity and sensitivity. This study describes the application of an LC-MS/MS-based approach toward the analysis of cobinamide in Yorkshire pig plasma. The selectivity, accuracy, precision, recovery, linearity, range, carryover, sensitivity, matrix effect, interference, stability, reproducibility, and ruggedness of the method were investigated in pig plasma. The accuracy and precision of the method was determined to be within 10% over three different days over a range of concentrations (25-10,000 ng/mL) that spanned more than two orders of magnitude. The lower limit of quantitation (LLOQ) for dicyanocobinamide was determined to be 25 ng/mL in pig plasma. Carryover was acceptable, as the area response of the carryover blanks were <= 15% of the area response of the nearest LLOQ standard for the analyte, while it was nonexistent for the internal standard. Specificity was ensured using six different lots of pig plasma. While the matrix effects of dicyanocobinamide in plasma were enhanced, ginsenoside Rb1 experienced signal suppression under the described conditions. The absolute recovery results for both compounds were consistent, precise, and reproducibly lower than expected at similar to 60% for dicyanocobinamide and similar to 22% for ginsenoside Rb1, confirming that a rnatrix standard curve was required for accurate quantitation. Cobinamide was shown to be very stable in matrix at various storage conditions including room temperature, refrigerated, and frozen at time intervals of 20 h, 4 days, and 60 days respectively. This method was demonstrated to be sensitive, reproducible, stable, and rugged, and it should be applicable to the analysis of cobinamide in other biological matrices and species. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:104 / 111
页数:8
相关论文
共 11 条
[1]  
Antonini, 1971, EUR J BIOCHEM, V23, P396
[2]  
Brittain M.K., 2014, TESTING COBINA UNPUB
[3]  
Broderick KE, 2007, EXP BIOL MED, V232, P789
[4]  
Broderick KE, 2006, EXP BIOL MED, V231, P641
[5]   Cobinamide is superior to other treatments in a mouse model of cyanide poisoning [J].
Chan, Adriano ;
Balasubramanian, Maheswari ;
Blackledge, William ;
Mohammad, Othman M. ;
Alvarez, Luis ;
Boss, Gerry R. ;
Bigby, Timothy D. .
CLINICAL TOXICOLOGY, 2010, 48 (07) :709-U55
[6]   Determination of cobalamins and cobinamides by microbore reversed-phase HPLC with spectrophotometric, ion-spray ionization MS and inductively coupled plasma MS detection [J].
Chassaigne, H ;
Lobinski, R .
ANALYTICA CHIMICA ACTA, 1998, 359 (03) :227-235
[7]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC ANALYSIS OF THE (CYANOAQUO) STEREOISOMERS OF SEVERAL PUTATIVE VITAMIN-B12 PRECURSORS [J].
FORD, SH ;
GALLERY, J ;
NICHOLS, A ;
SHAMBEE, M .
JOURNAL OF CHROMATOGRAPHY, 1991, 537 (1-2) :235-247
[8]  
James Romano Jr A., 2008, CHEM WARFARE AGENTS
[9]  
Jeremy Berg M., 2007, BIOCHEMISTRY-US
[10]  
Klaassen Curtis D., 2008, CASARETT DOULLS TOXI