Using N-aminoperylene-3,4:9,10-tetracarboxylbisimide as a fluorogenic reactand in the optical sensing of aqueous propionaldehyde

被引:54
作者
Mohr, GJ
Spichiger, UE
Jona, W
Langhals, H
机构
[1] ETH Technopk, Ctr Chem Sensors, CH-8005 Zurich, Switzerland
[2] Univ Munich, Inst Organ Chem, D-81377 Munich, Germany
关键词
D O I
10.1021/ac991171t
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Aldehydes are usually determined via chemical derivatization using a chromogenic and fluorogenic reagent followed by chromatographic separation and W-visible detection. As a consequence, continuous on-line monitoring is impossible, Following our concept of reversible chemical reactions as the basis of optical sensors, we have investigated N-amino-N'-(1-hexylheptyl)perylene-3,4:9,-10-tehracarboxylbisimide for aldehyde sensing. The fluorogenic reactand has been embedded in plasticized PVC, and the resulting thin layers have been exposed to aqueous samples of aliphatic aldehydes and ketones. The reactand exhibits a pronounced increase in fluorescence upon interaction with aldehydes since the chemical reaction causes a dequenching of perylene fluorescence, Upon interaction with aqueous propionaldehyde, sensor layers typically exhibit a dynamic range from 5 to 100 mM propionaldehyde, and the limit of detection amounts to 0.08 mM, The forward and reverse response time (tss) for a decade change in activity is in the range of 2-7 min, when measured at pH 2.5. The selectivity of sensor layers toward aldehydes correlates with their Lipophilicity in that aldehydes with higher lipophilicity are more efficiently extracted into the polymer layer.
引用
收藏
页码:1084 / 1087
页数:4
相关论文
共 21 条
  • [1] DETERMINATION OF FORMALDEHYDE IN AIR BY MEANS OF CHROMOTROPIC-ACID .1. INVESTIGATIONS ON THE STABILITY OF THE REAGENT
    BACHHAUSEN, P
    BUCHHOLZ, N
    HARTKAMP, H
    [J]. FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1985, 320 (04): : 347 - 349
  • [2] Optodes based on a calixarene ester for the determination of aldehydes via in situ generation of the Girard's reagent P derivative
    Chan, WH
    Wu, XJ
    [J]. ANALYST, 1998, 123 (12) : 2851 - 2856
  • [3] CHEMICAL SENSORS BASED ON SNO2 AND WO3 FOR THE DETECTION OF FORMALDEHYDE - COOPERATIVE EFFECTS
    DAZA, L
    DASSY, S
    DELMON, B
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 1993, 10 (02) : 99 - 105
  • [4] Response function and analytical parameters of nitrite-selective optode membranes in absorbance and fluorescence mode
    Demuth, C
    Spichiger, UE
    [J]. ANALYTICA CHIMICA ACTA, 1997, 355 (2-3) : 259 - 268
  • [5] Direct monitoring of formaldehyde vapour and detection of ethanol vapour using dehydrogenase-based biosensors
    Dennison, MJ
    Hall, JM
    Turner, APF
    [J]. ANALYST, 1996, 121 (12) : 1769 - 1773
  • [6] Dickinson R. G., 1970, CHEM COMMUN, P1719
  • [7] PIEZOELECTRIC CRYSTAL SENSOR FOR THE DETERMINATION OF FORMALDEHYDE IN AIR
    FATIBELLO-FILHO, O
    SULEIMAN, AA
    GUILBAULT, GG
    [J]. TALANTA, 1991, 38 (05) : 541 - 545
  • [8] Fluorometric determination of formaldehyde
    Girousi, ST
    Golia, EE
    Voulgaropoulos, AN
    Maroulis, AJ
    [J]. FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1997, 358 (05): : 667 - 668
  • [9] SYNTHESIS OF NONSYMMETRICALLY SUBSTITUTED PERYLENE FLUORESCENT DYES
    KAISER, H
    LINDNER, J
    LANGHALS, H
    [J]. CHEMISCHE BERICHTE, 1991, 124 (03) : 529 - 535
  • [10] Quantitative RP-HPLC determination of some aldehydes and hydroxyaldehydes as their 2,4-dinitrophenylhydrazone derivatives
    Koivusalmi, E
    Haatainen, E
    Root, A
    [J]. ANALYTICAL CHEMISTRY, 1999, 71 (01) : 86 - 91