Predicting effect of physical factors on tibial motion using artificial neural networks

被引:14
作者
Sari, Murat [1 ]
Cetiner, B. Gultekin [2 ]
机构
[1] Pamukkale Univ, Dept Math, Fac Arts & Sci, TR-20070 Denizli, Turkey
[2] IIUM, Dept Mfg Engn, Fac Engn, Kuala Lumpur 53100, Malaysia
关键词
Artificial neural network; Tibial rotation; Biomechanics; KNEE-JOINT; IN-VIVO; TIBIOFEMORAL MOVEMENT; COMPUTED-TOMOGRAPHY; LIVING KNEE; TORSION; MODELS; MRI; KINEMATICS; DEFICIENT;
D O I
10.1016/j.eswa.2009.02.030
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
The aim of this study was to predict the effect of physical factors on tibial motion by making use of artificial neural networks (ANNs). Since assessment of the tibial motion by the conventional approaches is generally difficult, this study aimed at the prediction of the relations between several physical factors (gender, age, body mass, and height) and tibial motion in terms of the ANNs. Data collected for 484 healthy subjects have been analyzed by using the ANNs. The study has given encouraging results for such a purpose. This investigation has been made to predict the rotations; especially the RTER prediction is highly satisfactory and the ANNs have been found to be very promising processing systems for modelling in the tibial rotation data assessments. (C) 2009 Elsevier Ltd. All rights reserved,
引用
收藏
页码:9743 / 9746
页数:4
相关论文
共 33 条
[1]   Isokinetic evaluation of internal/external tibial rotation strength after the use of hamstring tendons for anterior cruciate ligament reconstruction [J].
Armour, T ;
Forwell, L ;
Litchfield, R ;
Kirkleyt, A ;
Amendola, N ;
Fowler, PJ .
AMERICAN JOURNAL OF SPORTS MEDICINE, 2004, 32 (07) :1639-1643
[2]  
BATES BT, 1979, MED SCI SPORTS EXERC, V11, P24
[3]   MEASUREMENT OF TIBIAL TORSION - A NEW TECHNIQUE APPLICABLE TO ULTRASOUND AND COMPUTED-TOMOGRAPHY [J].
BUTLERMANUEL, PA ;
GUY, RL ;
HEATLEY, FW .
BRITISH JOURNAL OF RADIOLOGY, 1992, 65 (770) :119-126
[4]  
Cameron JC, 1996, CLIN ORTHOP RELAT R, P177
[5]  
Cimbiz A., 2006, J MED SCI, V6, P751
[6]  
Clement D B, 1981, Phys Sportsmed, V9, P47, DOI 10.1080/00913847.1981.11711077
[7]  
CLEMENTZ BG, 1989, ACTA RADIOL, V30, P75
[8]   In vivo tibiofemoral contact analysis using 3D MRI-based knee models [J].
DeFrate, LE ;
Sun, H ;
Gill, TJ ;
Rubash, HE ;
Li, GA .
JOURNAL OF BIOMECHANICS, 2004, 37 (10) :1499-1504
[9]   The movement of the knee studied by magnetic resonance imaging [J].
Freeman, MAR ;
Pinskerova, V .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2003, (410) :35-43
[10]   Three-dimensional tibiofemoral kinematics of the anterior cruciate ligament-deficient and reconstructed knee during walking [J].
Georgoulis, AD ;
Papadonikolakis, A ;
Papageorgiou, CD ;
Mitsou, A ;
Stergiou, N .
AMERICAN JOURNAL OF SPORTS MEDICINE, 2003, 31 (01) :75-79