Systematic Design of the Lead-Lag Network Method for Active Damping in LCL-Filter Based Three Phase Converters

被引:206
作者
Pena-Alzola, Rafael [1 ]
Liserre, Marco [1 ]
Blaabjerg, Frede [1 ]
Sebastian, Rafael [2 ]
Dannehl, Jorg [3 ]
Fuchs, Friedrich Wilhelm [4 ]
机构
[1] Aalborg Univ, Dept Energy Technol, DK-9220 Aalborg, Denmark
[2] Natl Univ Distance Learning, UNED, Dept Elect Elect & Control Engn, Madrid 28040, Spain
[3] Danfoss Solar Inverters AS, DK-6400 Sonderborg, Denmark
[4] Univ Kiel, Inst Power Elect & Elect Drives, D-24143 Kiel, Germany
关键词
Active damping; lead-lag; LCL-filter; rectifier; stability; voltage-source converter; VOLTAGE-SOURCE CONVERTERS;
D O I
10.1109/TII.2013.2263506
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Three-phase active rectifiers guarantee sinusoidal input currents and unity power factor at the price of a high switching frequency ripple. To adopt an LCL-filter, instead of an L-filter, allows using reduced values for the inductances and so preserving dynamics. However, stability problems can arise in the current control loop if the present resonance is not properly damped. Passive damping simply adds resistors in series with the LCL-filter capacitors. This simplicity is at the expense of increased losses and encumbrances. Active damping modifies the control algorithm to attain stability without using dissipative elements but, sometimes, needing additional sensors. This solution has been addressed in many publications. The lead-lag network method is one of the first reported procedures and continues being in use. However, neither there is a direct tuning procedure (without trial and error) nor its rationale has been explained. Thus, in this paper a straightforward procedure is developed to tune the lead-lag network with the help of software tools. The rationale of this procedure, based on the capacitor current feedback, is elucidated. Stability is studied by means of the root locus analysis in z-plane. Selecting the lead-lag network for the maximum damping in the closed-loop poles uses a simple optimization algorithm. The robustness against the grid inductance variation is also analyzed. Simulations and experiments confirm the validity of the proposed design flow.
引用
收藏
页码:43 / 52
页数:10
相关论文
共 45 条
[1]  
Aiguo Xu, 2009, 2009 4th IEEE Conference on Industrial Electronics and Applications, P3200, DOI 10.1109/ICIEA.2009.5138792
[2]  
[Anonymous], IEEE T IND IN PRESS
[3]   A novel control to actively damp resonance in input LC filter of a three-phase voltage source converter [J].
Blasko, V ;
Kaura, V .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1997, 33 (02) :542-550
[4]   A new mathematical model and control of a three-phase AC-DC voltage source converter [J].
Blasko, V ;
Kaura, V .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 1997, 12 (01) :116-123
[5]  
Bojrup M., 1999, THESIS LUND I TECHNO
[6]   Digital Control of Power Converters-A Survey [J].
Buccella, Concettina ;
Cecati, Carlo ;
Latafat, Hamed .
IEEE TRANSACTIONS ON INDUSTRIAL INFORMATICS, 2012, 8 (03) :437-447
[7]   Current control of voltage source converters connected to the grid through an LCL-filter [J].
Bueno, EJ ;
Espinosa, F ;
Rodríguez, FJ ;
Ureña, J ;
Cobreces, S .
PESC 04: 2004 IEEE 35TH ANNUAL POWER ELECTRONICS SPECIALISTS CONFERENCE, VOLS 1-6, CONFERENCE PROCEEDINGS, 2004, :68-73
[8]  
Buso S., 2006, Digital Control in Power Electronics, DOI [DOI 10.2200/S00047ED1V01Y200609PEL002, 10.2200/S00047ED1V01Y200609PEL002.]
[9]   Filter Optimization for Grid Interactive Voltage Source Inverters [J].
Channegowda, Parikshith ;
John, Vinod .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2010, 57 (12) :4106-4114
[10]  
Dahono PA, 2002, IEEE POWER ELECTRON, P1630