Monitoring and healing analysis of 100 tibial shaft fractures

被引:97
作者
Claes, L
Grass, R
Schmickal, T
Kisse, B
Eggers, C
Gerngross, H
Mutschler, W
Arand, M
Wintermeyer, T
Wentzensen, A
机构
[1] Univ Ulm, Inst Unfallchirurg Forsch & Biomech, D-89081 Ulm, Germany
[2] Klin Unfall & Wiederherstellungschirurg, D-01307 Dresden, Germany
[3] BG Unfallklin, D-67071 Ludwigshafen, Germany
[4] Stadt Klinikum, Klin Hand Brust & Plast Chirurg, D-23730 Neustadt, Germany
[5] Allgemeines Krankenhaus St Georg, Unfallchirurg Abt, D-20099 Hamburg, Germany
[6] Bundeswehrkrankenhaus Ulm, Chirurg Abt, Ulm, Germany
关键词
fractures; monitoring; healing;
D O I
10.1007/s00423-002-0306-x
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: We assessed the value of measuring biomechanical stiffness by assessing the fixator's external deformation as an objective means for monitoring fracture healing and determining the postoperative treatment regime, as compared to clinical and radiographic means of evaluation. Patients and methods: One hundred patients with tibial shaft fractures managed by unilateral external fixation had their fracture stiffness monitored. Stiffness was measured and clinical and radiological examinations were performed every 3-4 weeks. Results: The time required for healing as indicated by stiffness measurement was an average of 2.5 weeks earlier than by radiological assessment. Eighty-two patients healed within 19 weeks (12.1+/-3.3 weeks) and ten patients in the following 6 weeks (24+/-4.3 weeks). Eight patients did not show an increase in fracture stiffness and received intramedullary nailing at a second operation. The average healing time was 11.3+/-4 weeks for type A, 13.1+/-3.6 weeks for type B fractures, and 15.1+/-5.9 weeks for type C fractures. The healing time for closed fractures was 11.3+/-3.2 weeks and for open fractures 14+/-4.9 weeks. Conclusions: The measurement of fracture stiffness allows the detection of patients at risk for nonunions. The healing time increased with increasing fracture gap size and was less in patients with younger age, less complex fractures, and lesser degrees of soft tissue damage.
引用
收藏
页码:146 / 152
页数:7
相关论文
共 14 条
  • [1] BURNY F, 1984, ORTHOPEDICS, V7, P1823, DOI 10.3928/0147-7447-19841201-08
  • [2] Influence of size and stability of the osteotomy gap on the success of fracture healing
    Claes, L
    Augat, P
    Suger, G
    Wilke, HJ
    [J]. JOURNAL OF ORTHOPAEDIC RESEARCH, 1997, 15 (04) : 577 - 584
  • [3] CLAES L, 1991, CHIRURG, V62, P354
  • [4] DESIGN AND PERFORMANCE OF A FRACTURE MONITORING TRANSDUCER
    EVANS, M
    KENWRIGHT, J
    CUNNINGHAM, JL
    [J]. JOURNAL OF BIOMEDICAL ENGINEERING, 1988, 10 (01): : 64 - 69
  • [5] 3-DIMENSIONAL MOVEMENT AT EXTERNALLY FIXATED TIBIAL FRACTURES AND OSTEOTOMIES DURING NORMAL-PATIENT FUNCTION
    GARDNER, TN
    EVANS, M
    SIMPSON, AHRW
    TURNERSMITH, AR
    [J]. CLINICAL BIOMECHANICS, 1994, 9 (01) : 51 - 59
  • [6] PREVENTION OF INFECTION IN TREATMENT OF 1000 AND 25 OPEN FRACTURES OF LONG BONES - RETROSPECTIVE AND PROSPECTIVE ANALYSES
    GUSTILO, RB
    ANDERSON, JT
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1976, 58 (04) : 453 - 458
  • [7] HEIM D, 1990, HELV CHIR ACTA, V57, P839
  • [8] MEASUREMENTS OF STABILITY OF CRURAL FRACTURES TREATED WITH HOFFMANN OSTEOTAXIS .2. MEASUREMENTS ON CRURAL FRACTURES
    JORGENSEN, TE
    [J]. ACTA ORTHOPAEDICA SCANDINAVICA, 1972, 43 (03): : 207 - +
  • [9] KRETTEK C, 1989, UNFALLCHIRURG, V92, P440
  • [10] MANUAL SENSING OF FRACTURE STABILITY - BIOMECHANICAL STUDY
    MATTHEWS, LS
    KAUFER, H
    SONSTEGARD, DA
    [J]. ACTA ORTHOPAEDICA SCANDINAVICA, 1974, 45 (03): : 373 - 381