Accuracy of computer-aided template-guided oral implant placement: a prospective clinical study

被引:50
作者
Beretta, Mario [1 ]
Poli, Pier Paolo [1 ]
Maiorana, Carlo [1 ]
机构
[1] State Univ Milan, Fdn IRCCS Ca Granda, UOC Maxillofacial Surg & Odontostomatol, Dept Dent Implants, I-20122 Milan, Italy
关键词
Computer-aided design; Dental implants; X-ray computed tomography; STEREOLITHOGRAPHIC SURGICAL GUIDES; DENTAL IMPLANTS; TECHNOLOGY APPLICATIONS; FLAPLESS SURGERY; HUMAN CADAVERS; RECONSTRUCTION; DENTISTRY; COMPLICATIONS; FABRICATION; TOMOGRAPHY;
D O I
10.5051/jpis.2014.44.4.184
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: The aim of the present study was to evaluate the in vivo accuracy of flapless, computer-aided implant placement by comparing the three-dimensional (3D) position of planned and placed implants through an analysis of linear and angular deviations. Methods: Implant position was virtually planned using 3D planning software based on the functional and aesthetic requirements of the final restorations. Computer-aided design/computer-assisted manufacture technology was used to transfer the virtual plan to the surgical environment. The 3D position of the planned and placed implants, in terms of the linear deviations of the implant head and apex and the angular deviations of the implant axis, was compared by overlapping the pre- and postoperative computed tomography scans using dedicated software. Results: The comparison of 14 implants showed a mean linear deviation of the implant head of 0.56 mm (standard deviation [SD], 0.23), a mean linear deviation of the implant apex of 0.64 mm (SD, 0.29), and a mean angular deviation of the long axis of 2.42 degrees (SD, 1.02). Conclusions: In the present study, computer-aided flapless implant surgery seemed to provide several advantages to the clinicians as compared to the standard procedure; however, linear and angular deviations are to be expected. Therefore, accurate presurgical planning taking into account anatomical limitations and prosthetic demands is mandatory to ensure a predictable treatment, without incurring possible intra- and postoperative complications.
引用
收藏
页码:184 / 193
页数:10
相关论文
共 41 条
[1]   Fabrication of imaging and surgical guides for dental implants [J].
Almog, DM ;
Torrado, E ;
Meitner, SW .
JOURNAL OF PROSTHETIC DENTISTRY, 2001, 85 (05) :504-508
[2]   Surgical guide for dental implant placement [J].
Becker, CM ;
Kaiser, DA .
JOURNAL OF PROSTHETIC DENTISTRY, 2000, 83 (02) :248-251
[3]  
Brodala N, 2009, INT J ORAL MAX IMPL, V24, P118
[4]   Depth deviation and occurrence of early surgical complications or unexpected events using a single stereolithographic surgi-guide [J].
Cassetta, M. ;
Stefanelli, L. V. ;
Giansanti, M. ;
Di Mambro, A. ;
Calasso, S. .
INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2011, 40 (12) :1377-1387
[5]   Quality and quantity of bone following alveolar distraction osteogenesis in the human mandible [J].
Chiapasco, Matteo ;
Lang, Niklaus P. ;
Bosshardt, Dieter D. .
CLINICAL ORAL IMPLANTS RESEARCH, 2006, 17 (04) :394-402
[6]   Accuracy and Complications Using Computer-Designed Stereolithographic Surgical Guides for Oral Rehabilitation by Means of Dental Implants: A Review of the Literature [J].
D'haese, Jan ;
Van De Velde, Tommie ;
Komiyama, Ai ;
Hultin, Margaretha ;
De Bruyn, Hugo .
CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2012, 14 (03) :321-335
[7]   A Prospective Study on the Accuracy of Mucosally Supported Stereolithographic Surgical Guides in Fully Edentulous Maxillae [J].
D'haese, Jan ;
Van De Velde, Tommie ;
Elaut, Lucien ;
De Bruyn, Hugo .
CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2012, 14 (02) :293-303
[8]   Clinical Outcome and Bone Preservation of Single TiUnite™ Implants Installed with Flapless or Flap Surgery [J].
De Bruyn, Hugo ;
Atashkadeh, Mandana ;
Cosyn, Jan ;
van de Velde, Tommie .
CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2011, 13 (03) :175-183
[9]  
Di Giacomo GAP, 2005, J PERIODONTOL, V76, P503
[10]  
Engelke WGH, 1997, INT J ORAL MAX IMPL, V12, P310