Catheter displacement prior to the delivery of high-dose-rate brachytherapy in the treatment of prostate cancer patients

被引:15
|
作者
Kawakami, Shogo [1 ,2 ]
Ishiyama, Hiromichi [1 ,2 ]
Terazaki, Tsuyoshi [3 ]
Soda, Itaru [1 ,2 ]
Satoh, Takefumi [4 ]
Kitano, Masashi [1 ,2 ]
Kurosaka, Shinji [4 ]
Sekiguchi, Akane [1 ,2 ]
Komori, Shouko [1 ,2 ]
Iwamura, Masatsugu [4 ]
Hayakawa, Kazushige [1 ,2 ]
机构
[1] Kitasato Univ Hosp, Dept Radiol, Sagamihara, Kanagawa, Japan
[2] Kitasato Univ Hosp, Dept Radiat Oncol, Sagamihara, Kanagawa, Japan
[3] Kitasato Univ Hosp, Div Radiat Oncol, Sagamihara, Kanagawa, Japan
[4] Kitasato Univ, Sch Med, Dept Urol, Sagamihara, Kanagawa 228, Japan
关键词
brachytherapy; catheter displacement; high-dose-rate; prostate cancer; HDR-BRACHYTHERAPY; MOVEMENT;
D O I
10.5114/jcb.2014.43619
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: The purpose of this work was to report measured catheter displacement prior to the delivery of high-dose-rate brachytherapy (HDR) in the treatment of prostate cancer. Material and methods: Data from 30 prostate cancer patients treated with HDR brachytherapy were analyzed retrospectively. Eighteen transperineal hollow catheters were inserted under transrectal ultrasound guidance. Gold marker seeds were also placed transperineally into the base and apex of the prostate gland. Five treatment fractions of 7.5 Gy each were administered over 3 days. The patient underwent CT scanning prior to each treatment fraction. Catheter displacement was measured from the pre-treatment CT dataset reconstructed at 1.25 mm slice thickness. Results: Most of catheters were displaced in the caudal direction. Variations of 18 catheters for each patient were small (standard deviations < 1 mm for all but one patient). Mean displacements relative to the apex marker were 6 +/- 4 mm, 12 +/- 6 mm, 12 +/- 6 mm, 12 +/- 6 mm, and 12 +/- 6 mm from plan to 1st, 2nd, 3rd, 4th, and 5th fractions, respectively. Conclusions: Our results indicate that catheter positions must be confirmed and if required, adjusted, prior to every treatment fraction for the precise treatment delivery of HDR brachytherapy, and to potentially reduce over-dosage to the bulbo-membranous urethra.
引用
收藏
页码:161 / 166
页数:6
相关论文
共 50 条
  • [41] Biochemical outcome of prostate cancer patients treated with hypofractionated external radiation and a single high-dose-rate brachytherapy boost
    Olsen, Johan Staby
    Valachis, Antonios
    Phlic, Leif Karlsson
    Johansson, Bengt
    BRACHYTHERAPY, 2025, 24 (01) : 45 - 53
  • [42] High-dose-rate brachytherapy monotherapy versus low-dose-rate brachytherapy with or without external beam radiotherapy for clinically localized prostate cancer
    Yamazaki, Hideya
    Masui, Koji
    Suzuki, Gen
    Nakamura, Satoaki
    Yamada, Kei
    Okihara, Koji
    Shiraishi, Takumi
    Yoshida, Ken
    Kotsuma, Tadayuki
    Tanaka, Eiichi
    Otani, Keisuke
    Yoshioka, Yasuo
    Ogawa, Kazuhiko
    RADIOTHERAPY AND ONCOLOGY, 2019, 132 : 162 - 170
  • [43] Bi-objective optimization of catheter positions for high-dose-rate prostate brachytherapy
    van der Meer, Marjolein C.
    Bosman, Peter A. N.
    Niatsetski, Yury
    Alderliesten, Tanja
    van Wieringen, Niek
    Pieters, Bradley R.
    Bel, Arjan
    MEDICAL PHYSICS, 2020, 47 (12) : 6077 - 6086
  • [44] High-dose-rate brachytherapy in lower eyelid cancer
    Martinez-Monge, Rafael
    Gomez-Iturriaga, Alfonso
    BRACHYTHERAPY, 2007, 6 (03) : 227 - 229
  • [45] Role of high dose rate brachytherapy in the treatment of prostate cancer
    Ghilezan, M.
    CANCER RADIOTHERAPIE, 2012, 16 (5-6): : 418 - 422
  • [46] Biologic treatment planning for high-dose-rate brachytherapy
    Manning, MA
    Zwicker, RD
    Arthur, DW
    Arnfield, M
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 49 (03): : 839 - 845
  • [47] Second salvage high-dose-rate brachytherapy for radiorecurrent prostate cancer
    Maenhout, Metha
    van Vulpen, Marco
    Moerland, Marinus
    Peters, Max
    Meijer, Richard
    van den Bosch, Maurice
    Nguyen, Paul
    Frank, Steven
    van Zyp, Jochem van der Voort
    JOURNAL OF CONTEMPORARY BRACHYTHERAPY, 2017, 9 (02) : 161 - 166
  • [48] High-dose-rate brachytherapy for prostate cancer: Rationale, current applications, and clinical outcome
    Strouthos, Iosif
    Karagiannis, Efstratios
    Zamboglou, Nikolaos
    Ferentinos, Konstantinos
    CANCER REPORTS, 2022, 5 (01)
  • [49] Salvage high-dose-rate brachytherapy for local prostate cancer recurrence after radiotherapy - preliminary results
    Jo, Yoshimasa
    Fujii, Tomohiro
    Hara, Ryoei
    Yokoyama, Teruhiko
    Miyaji, Yoshiyuki
    Yoden, Eisaku
    Hiratsuka, Junichi
    Nagai, Atsushi
    BJU INTERNATIONAL, 2012, 109 (06) : 835 - 839
  • [50] Predicting toxicity caused by high-dose-rate brachytherapy single boost for prostate cancer
    Olsen, Johan Staby
    Estefan, Dalia
    Valachis, Antonios
    Jakobsson, Frida
    Karlsson, Leif
    Johansson, Bengt
    JOURNAL OF CONTEMPORARY BRACHYTHERAPY, 2022, 14 (01) : 7 - 14