Catheter displacement prior to the delivery of high-dose-rate brachytherapy in the treatment of prostate cancer patients

被引:15
|
作者
Kawakami, Shogo [1 ,2 ]
Ishiyama, Hiromichi [1 ,2 ]
Terazaki, Tsuyoshi [3 ]
Soda, Itaru [1 ,2 ]
Satoh, Takefumi [4 ]
Kitano, Masashi [1 ,2 ]
Kurosaka, Shinji [4 ]
Sekiguchi, Akane [1 ,2 ]
Komori, Shouko [1 ,2 ]
Iwamura, Masatsugu [4 ]
Hayakawa, Kazushige [1 ,2 ]
机构
[1] Kitasato Univ Hosp, Dept Radiol, Sagamihara, Kanagawa, Japan
[2] Kitasato Univ Hosp, Dept Radiat Oncol, Sagamihara, Kanagawa, Japan
[3] Kitasato Univ Hosp, Div Radiat Oncol, Sagamihara, Kanagawa, Japan
[4] Kitasato Univ, Sch Med, Dept Urol, Sagamihara, Kanagawa 228, Japan
关键词
brachytherapy; catheter displacement; high-dose-rate; prostate cancer; HDR-BRACHYTHERAPY; MOVEMENT;
D O I
10.5114/jcb.2014.43619
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: The purpose of this work was to report measured catheter displacement prior to the delivery of high-dose-rate brachytherapy (HDR) in the treatment of prostate cancer. Material and methods: Data from 30 prostate cancer patients treated with HDR brachytherapy were analyzed retrospectively. Eighteen transperineal hollow catheters were inserted under transrectal ultrasound guidance. Gold marker seeds were also placed transperineally into the base and apex of the prostate gland. Five treatment fractions of 7.5 Gy each were administered over 3 days. The patient underwent CT scanning prior to each treatment fraction. Catheter displacement was measured from the pre-treatment CT dataset reconstructed at 1.25 mm slice thickness. Results: Most of catheters were displaced in the caudal direction. Variations of 18 catheters for each patient were small (standard deviations < 1 mm for all but one patient). Mean displacements relative to the apex marker were 6 +/- 4 mm, 12 +/- 6 mm, 12 +/- 6 mm, 12 +/- 6 mm, and 12 +/- 6 mm from plan to 1st, 2nd, 3rd, 4th, and 5th fractions, respectively. Conclusions: Our results indicate that catheter positions must be confirmed and if required, adjusted, prior to every treatment fraction for the precise treatment delivery of HDR brachytherapy, and to potentially reduce over-dosage to the bulbo-membranous urethra.
引用
收藏
页码:161 / 166
页数:6
相关论文
共 50 条
  • [31] HIGH-DOSE-RATE BRACHYTHERAPY BOOST FOR PROSTATE CANCER: COMPARISON OF TWO DIFFERENT FRACTIONATION SCHEMES
    Kaprealian, Tanta
    Weinberg, Vivian
    Speight, Joycelyn L.
    Gottschalk, Alexander R.
    Roach, Mack, III
    Shinohara, Katsuto
    Hsu, I. -Chow
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 82 (01): : 222 - 227
  • [32] High-dose-rate brachytherapy as monotherapy for prostate cancer: technique, rationale and perspective
    Yoshioka, Yasuo
    Suzuki, Osamu
    Otani, Yuki
    Yoshida, Ken
    Nose, Takayuki
    Ogawa, Kazuhiko
    JOURNAL OF CONTEMPORARY BRACHYTHERAPY, 2014, 6 (01) : 91 - 98
  • [33] Urinary incontinence after high-dose-rate brachytherapy boost treatment for prostate cancer
    Kragelj, Borut
    Zaletel-Kragelj, Lijana
    BRACHYTHERAPY, 2016, 15 (04) : 442 - 449
  • [34] Monotherapeutic high-dose-rate brachytherapy for prostate cancer: A dose reduction trial
    Yoshioka, Yasuo
    Konishi, Koji
    Suzuki, Osamu
    Nakai, Yasutomo
    Isohashi, Fumiaki
    Seo, Yuji
    Otani, Yuki
    Koizumi, Masahiko
    Yoshida, Ken
    Yamazaki, Hideya
    Nonomura, Norio
    Ogawa, Kazuhiko
    RADIOTHERAPY AND ONCOLOGY, 2014, 110 (01) : 114 - 119
  • [35] Measurement of craniocaudal catheter displacement between fractions in computed tomography-based high dose rate brachytherapy of prostate cancer
    Kim, Yongbok
    Hsu, I-Chow J.
    Pouliot, Jean
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2007, 8 (04): : 1 - 13
  • [36] Assessment of Daily Needle Applicator Displacement during High-Dose-Rate Interstitial Brachytherapy for Prostate Cancer using Daily CT Examinations
    Takenaka, Tadashi
    Yoshida, Ken
    Ueda, Mari
    Yamazaki, Hideya
    Miyake, Shunsuke
    Tanaka, Eiichi
    Yoshida, Mineo
    Yoshimura, Yasushi
    Oka, Toshitsugu
    Honda, Kazuya
    JOURNAL OF RADIATION RESEARCH, 2012, 53 (03) : 469 - 474
  • [37] High dose rate prostate brachytherapy
    Nickers, P.
    Blanchard, P.
    Hannoun-Levi, J-M
    Bossi, A.
    Chapet, O.
    Guerif, S.
    CANCER RADIOTHERAPIE, 2013, 17 (02): : 118 - 124
  • [38] Salvage high-dose-rate brachytherapy for local recurrence of prostate cancer
    Yagudaev, D. M.
    Kadyrov, Z. A.
    Kalinin, M. R.
    Bezhenar, V. A.
    Kalyagina, N. A.
    ONKOUROLOGIYA, 2018, 14 (02): : 171 - 175
  • [39] Improved survival for patients with prostate cancer receiving high-dose-rate brachytherapy boost to EBRT compared with EBRT alone
    Kent, Aaron R.
    Matheson, Bronwyn
    Millar, Jeremy L.
    BRACHYTHERAPY, 2019, 18 (03) : 313 - 321
  • [40] American Brachytherapy Society consensus guidelines for high-dose-rate prostate brachytherapy
    Yamada, Yoshiya
    Rogers, Leland
    Demanes, D. Jeffrey
    Morton, Gerard
    Prestidges, Bradley R.
    Pouliot, Jean
    Cohen, Gil'ad N.
    Zaider, Marco
    Ghilezan, Mihai
    Hsu, I-Chow
    BRACHYTHERAPY, 2012, 11 (01) : 20 - 32