Catheter displacement prior to the delivery of high-dose-rate brachytherapy in the treatment of prostate cancer patients

被引:15
|
作者
Kawakami, Shogo [1 ,2 ]
Ishiyama, Hiromichi [1 ,2 ]
Terazaki, Tsuyoshi [3 ]
Soda, Itaru [1 ,2 ]
Satoh, Takefumi [4 ]
Kitano, Masashi [1 ,2 ]
Kurosaka, Shinji [4 ]
Sekiguchi, Akane [1 ,2 ]
Komori, Shouko [1 ,2 ]
Iwamura, Masatsugu [4 ]
Hayakawa, Kazushige [1 ,2 ]
机构
[1] Kitasato Univ Hosp, Dept Radiol, Sagamihara, Kanagawa, Japan
[2] Kitasato Univ Hosp, Dept Radiat Oncol, Sagamihara, Kanagawa, Japan
[3] Kitasato Univ Hosp, Div Radiat Oncol, Sagamihara, Kanagawa, Japan
[4] Kitasato Univ, Sch Med, Dept Urol, Sagamihara, Kanagawa 228, Japan
关键词
brachytherapy; catheter displacement; high-dose-rate; prostate cancer; HDR-BRACHYTHERAPY; MOVEMENT;
D O I
10.5114/jcb.2014.43619
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: The purpose of this work was to report measured catheter displacement prior to the delivery of high-dose-rate brachytherapy (HDR) in the treatment of prostate cancer. Material and methods: Data from 30 prostate cancer patients treated with HDR brachytherapy were analyzed retrospectively. Eighteen transperineal hollow catheters were inserted under transrectal ultrasound guidance. Gold marker seeds were also placed transperineally into the base and apex of the prostate gland. Five treatment fractions of 7.5 Gy each were administered over 3 days. The patient underwent CT scanning prior to each treatment fraction. Catheter displacement was measured from the pre-treatment CT dataset reconstructed at 1.25 mm slice thickness. Results: Most of catheters were displaced in the caudal direction. Variations of 18 catheters for each patient were small (standard deviations < 1 mm for all but one patient). Mean displacements relative to the apex marker were 6 +/- 4 mm, 12 +/- 6 mm, 12 +/- 6 mm, 12 +/- 6 mm, and 12 +/- 6 mm from plan to 1st, 2nd, 3rd, 4th, and 5th fractions, respectively. Conclusions: Our results indicate that catheter positions must be confirmed and if required, adjusted, prior to every treatment fraction for the precise treatment delivery of HDR brachytherapy, and to potentially reduce over-dosage to the bulbo-membranous urethra.
引用
收藏
页码:161 / 166
页数:6
相关论文
共 50 条
  • [1] Robustness of IPSA optimized high-dose-rate prostate brachytherapy treatment plans to catheter displacements
    Poder, Joel
    Whitaker, May
    JOURNAL OF CONTEMPORARY BRACHYTHERAPY, 2016, 8 (03) : 203 - 209
  • [2] High-dose-rate brachytherapy boost for prostate cancer: Outcomes and genitourinary toxicity
    Bece, Andrej
    Patanjali, Nitya
    Jackson, Michael
    Whitaker, May
    Hruby, George
    BRACHYTHERAPY, 2015, 14 (05) : 670 - 676
  • [3] Needle applicator displacement during high-dose-rate interstitial brachytherapy for prostate cancer
    Yoshida, Ken
    Yamazaki, Hideya
    Nose, Takayuki
    Shiomi, Hiroya
    Yoshida, Mineo
    Mikami, Mari
    Takenaka, Tadashi
    Kotsuma, Tadayuki
    Tanaka, Eiichi
    Kuriyama, Keiko
    Harada, Yasunori
    Tohda, Akira
    Yasunaga, Yutaka
    Oka, Toshitsugu
    BRACHYTHERAPY, 2010, 9 (01) : 36 - 41
  • [4] High-dose-rate brachytherapy as monotherapy for prostate cancer
    Demanes, D. Jeffrey
    Ghilezan, Michel I.
    BRACHYTHERAPY, 2014, 13 (06) : 529 - 541
  • [5] HIGH-DOSE-RATE MONOTHERAPY: SAFE AND EFFECTIVE BRACHYTHERAPY FOR PATIENTS WITH LOCALIZED PROSTATE CANCER
    Demanes, D. Jeffrey
    Martinez, Alvaro A.
    Ghilezan, Michel
    Hill, Dennis R.
    Schour, Lionel
    Brandt, David
    Gustafson, Gary
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 81 (05): : 1286 - 1292
  • [6] High-Dose-Rate Prostate Brachytherapy An Excellent Accelerated-Hypofractionated Treatment for Favorable Prostate Cancer
    Martinez, Alvaro A.
    Demanes, Jeffrey
    Vargas, Carlos
    Schour, Lionel
    Ghilezan, Michel
    Gustafson, Gary S.
    AMERICAN JOURNAL OF CLINICAL ONCOLOGY-CANCER CLINICAL TRIALS, 2010, 33 (05): : 481 - 488
  • [7] Treatment patterns of high-dose-rate and low-dose-rate brachytherapy as monotherapy for prostate cancer
    Barnes, Justin
    Kennedy, William R.
    Fischer-Valuck, Benjamin W.
    Baumann, Brian C.
    Michalski, Jeff M.
    Gay, Hiram A.
    JOURNAL OF CONTEMPORARY BRACHYTHERAPY, 2019, 11 (04) : 320 - 328
  • [8] Low-dose-rate or high-dose-rate brachytherapy in treatment of prostate cancer - between options
    Skowronek, Janusz
    JOURNAL OF CONTEMPORARY BRACHYTHERAPY, 2013, 5 (01) : 33 - 41
  • [9] High-dose-rate brachytherapy in combination with conformal external beam radiotherapy in the treatment of prostate cancer
    Zwahlen, Daniel R.
    Andrianopoulos, Nick
    Matheson, Bronwyn
    Duchesne, Gillian M.
    Millar, Jeremy L.
    BRACHYTHERAPY, 2010, 9 (01) : 27 - 35
  • [10] Simultaneous needle catheter selection and dwell time optimization for preplanning of high-dose-rate brachytherapy of prostate cancer
    Wang, Chao
    Gonzalez, Yesenia
    Shen, Chenyang
    Hrycushko, Brian
    Jia, Xun
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (05):