摘要
Internal fixation of intracapsular hip fractures results in a high failure rate with non-union and avascular necrosis being the two most important complications. In order to prevent these possible complications treatment should consist of an anatomical reduction and stable fixation by insertion of a low volume, dynamic implant, providing angular and rotational stability to the femoral head. According to these principles a new implant, the dynamic locking blade plate (DLBP) was designed for the fixation of intracapsular hip fractures. We performed a biomechanical analysis in synthetic bone to compare the rotational stability and cut out resistance of the DLBP with a conventional sliding hip screw(SHS) and the more recently developed Twin Hook. The rotational stability of the DLBP proved to be three times higher than the rotational stability of a SHS and two times higher than the Twin Hook. There was no major difference in cut out resistance between the different implants. The design of the DLBP and possible advantages with regard to the healing of an intracapsular hip fracture are discussed. (C) 2008 Elsevier Ltd. All rights reserved.
引用
收藏
页码:283 / 287
页数:5
相关论文
共 30 条
[1]   Operative management of displaced femoral neck fractures in elderly patients - An international survey [J].
Bhandari, M ;
Devereaux, PJ ;
Tornetta, P ;
Swiontkowski, MF ;
Berry, DJ ;
Haidukewych, G ;
Schemitsch, EH ;
Hanson, BP ;
Koval, K ;
Dirschl, D ;
Leece, P ;
Keel, M ;
Petrisor, B ;
Heetveld, M ;
Guyatt, GH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2005, 87A (09) :2122-2130
[2]   Internal fixation compared with arthroplasty for displaced fractures of the femoral neck - A meta-analysis [J].
Bhandari, M ;
Devereaux, PJ ;
Swiontkowski, MF ;
Tornetta, P ;
Obremskey, W ;
Koval, KJ ;
Nork, S ;
Sprague, S ;
Schemitsch, EH ;
Guyatt, GH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2003, 85A (09) :1673-1681
[3]   Biomechanical analysis of the percutaneous compression plate and sliding hip screw in intracapsular hip fractures: Experimental assessment using synthetic and cadaver bones [J].
Brandt, Erwin ;
Verdonschot, Nico ;
van Vugt, Arie ;
van Kampen, Albert .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2006, 37 (10) :979-983
[4]  
BRAY TJ, 1988, CLIN ORTHOP RELAT R, P127
[5]   Internal forces and moments in the femur during walking [J].
Duda, GN ;
Schneider, E ;
Chao, EYS .
JOURNAL OF BIOMECHANICS, 1997, 30 (09) :933-941
[6]  
HAUSMANN TJ, 2006, OSTEO TRAUMA CARE, V14, P259
[7]   Internal fixation for displaced fractures of the femoral neck - Does bone density affect clinical outcome? [J].
Heetveld, MJ ;
Raaymakers, ELFB ;
van Eck-Smit, BL ;
van Walsum, ADP ;
Luitse, JSK .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2005, 87B (03) :367-373
[8]   Fixation of intracapsular femoral neck fractures with a one-hole plate dynamic hip screw [J].
HeyseMoore, GH .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 1996, 27 (03) :181-183
[9]  
Kuner E. H., 1995, Unfallchirurg, V98, P251
[10]   AVASCULAR FEMORAL-HEAD NECROSIS FOLLOWING FRACTURE FIXATION [J].
LINDE, F ;
ANDERSEN, E ;
HVASS, I ;
MADSEN, F ;
PALLESEN, R .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 1986, 17 (03) :159-163