Intimal hyperplasia and vascular remodeling after everolimus-eluting and sirolimus-eluting stent implantation in diabetic patients: The randomized diabetes and drug-eluting stent (DiabeDES) IV intravascular ultrasound trial

被引:7
作者
Antonsen, Lisbeth [1 ]
Maeng, Michael [2 ]
Thayssen, Per [1 ]
Christiansen, Evald Hoj [2 ]
Hansen, Knud Norregaard [1 ]
Kaltoft, Anne [2 ]
Hansen, Henrik Steen [1 ]
Thuesen, Leif [2 ]
Lassen, Jens Flensted [2 ]
Jensen, Lisette Okkels [1 ]
机构
[1] Odense Univ Hosp, Dept Cardiol, DK-5000 Odense C, Denmark
[2] Aarhus Univ Hosp, Dept Cardiol, Skejby, Denmark
关键词
PCI; percutaneous coronary intervention; STENT; DIAB; diabetes; AD; coronary artery disease; stent structure; IVUS; intravascular ultrasound; CORONARY-ARTERY LESIONS; NATIONAL HEART; MELLITUS; RESTENOSIS; REVASCULARIZATION; ANGIOPLASTY; ANGIOGRAPHY; OUTCOMES; REGISTRY; LUNG;
D O I
10.1002/ccd.25180
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective To evaluate the effects of the everolimus-eluting Xience (TM)/Promus (TM) stent (EES) and the sirolimus-eluting Cypher (TM) stent (SES) on intimal hyperplasia (IH) in diabetic patients. Background Patients with diabetes mellitus have increased risk of in-stent restenosis after coronary stent implantation due to intimal hyperplasia (IH). Methods In a sub study of the Randomized Comparison of Everolimus-Eluting and Sirolimus-Eluting Stents in Patients Treated with Percutaneous Coronary Intervention (SORT OUT IV trial), serial intravascular ultrasound (IVUS) 10-month follow-up data were available in 88 patients, including 48 EES and 40 SES treated patients. IVUS endpoints included IH volume, in-stent % volume obstruction and changes in external elastic membrane (EEM) volume. Results Compared with the SES group, IH volume was increased in the EES group [median (interquartile range): 2.8 mm(3) (0.0-12.6) vs. 0.0 mm(3) (0.0-1.1), P = 0.001]. In-stent % volume obstruction was increased in EES compared to SES [median (interquartile range): 1.6% (0.0-8.2) vs. 0.0% (0.0-1.0), P = 0.001]. Peri-stent external elastic membrane (EEM) volume: (post procedure vs. follow-up EES [300 mm(3) (219-491) vs. 307 mm(3) (223-482), P = 0.73] and SES [316 mm(3) (235-399) vs. 323 mm(3) (246-404), P = 0.05]) and peri-stent plaque volume: EES [163 mm(3) (103-273) vs. 184 mm(3) (115-291), P = 0.18] and SES [186 mm(3) (139-248) vs. 175 mm(3) (153-243), P = 0.26]) were unchanged in both groups. In the proximal reference segment a significant increase in plaque area was seen in the EES group only, without vascular remodeling. Conclusion In diabetic patients, EES stent implantation was associated with increased IH volume obstruction without involvement of vascular remodeling. (c) 2013 Wiley Periodicals, Inc.
引用
收藏
页码:864 / 872
页数:9
相关论文
共 50 条
  • [41] Intravascular ultrasound assessment of optimal stent area to prevent in-stent restenosis after zotarolimus-, everolimus-, and sirolimus-eluting stent implantation
    Song, Hae-Geun
    Kang, Soo-Jin
    Ahn, Jung-Min
    Kim, Won-Jang
    Lee, Jong-Young
    Park, Duk-Woo
    Lee, Seung-Whan
    Kim, Young-Hak
    Lee, Cheol Whan
    Park, Seong-Wook
    Park, Seung-Jung
    [J]. CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2014, 83 (06) : 873 - 878
  • [42] Outcomes After Unrestricted Use of Everolimus-Eluting Stent Compared to Paclitaxel- and Sirolimus-Eluting Stents
    Mahmoudi, Michael
    Delhaye, Cedric
    Wakabayashi, Kohei
    Ben-Dor, Itsik
    Gonzalez, Manuel A.
    Maluenda, Gabriel
    Gaglia, Michael A., Jr.
    Torguson, Rebecca
    Xue, Zhenyi
    Suddath, William O.
    Satler, Lowell F.
    Kent, Kenneth M.
    Pichard, Augusto D.
    Waksman, Ron
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2011, 107 (12) : 1757 - 1762
  • [43] Everolimus-Eluting Versus Biolimus-Eluting Coronary Stent Implantation in Patients With and Without Diabetes Mellitus
    Gyldenkerne, Christine
    Olesen, Kevin K. W.
    Jensen, Lisette O.
    Junker, Anders
    Veien, Karsten T.
    Terkelsen, Christian J.
    Kristensen, Steen D.
    Thim, Troels
    Jensen, Svend E.
    Raungaard, Bent
    Aaroe, Jens
    Kahlert, Johnny
    Villadsen, Anton B.
    Botker, Hans Erik
    Christiansen, Evald H.
    Maeng, Michael
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2019, 124 (05) : 671 - 677
  • [44] Meta-analysis of everolimus-eluting stent as compared to sirolimus-eluting stent in patients undergoing percutaneous coronary interventions: An update
    Chen, Honglin
    Liu, Kun
    [J]. INTERNATIONAL JOURNAL OF CARDIOLOGY, 2011, 150 (01) : 101 - 103
  • [45] Mechanisms of In-Stent Restenosis After Drug-Eluting Stent Implantation Intravascular Ultrasound Analysis
    Kang, Soo-Jin
    Mintz, Gary S.
    Park, Duk-Woo
    Lee, Seung-Whan
    Kim, Young-Hak
    Lee, Cheol Whan
    Han, Ki-Hoon
    Kim, Jae-Joong
    Park, Seong-Wook
    Park, Seung-Jung
    [J]. CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2011, 4 (01) : 9 - 14
  • [46] Coronary Aneurysms After Drug-Eluting Stent Implantation Clinical, Angiographic, and Intravascular Ultrasound Findings
    Alfonso, Fernando
    Perez-Vizcayno, Maria-Jose
    Ruiz, Miguel
    Suarez, Alfonso
    Cazares, Miguel
    Hernandez, Rosana
    Escaned, Javier
    Banuelos, Camino
    Jimenez-Quevedo, Pilar
    Macaya, Carlos
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2009, 53 (22) : 2053 - 2060
  • [47] 7-Year Outcomes of a Randomized Trial Comparing the First-Generation Sirolimus-Eluting Stent Versus the New-Generation Everolimus-Eluting Stent The RESET Trial
    Shiomi, Hiroki
    Kozuma, Ken
    Morimoto, Takeshi
    Kadota, Kazushige
    Tanabe, Kengo
    Morino, Yoshihiro
    Akasaka, Takashi
    Abe, Mitsuru
    Takeji, Yasuaki
    Suwa, Satoru
    Ito, Yoshiaki
    Kobayashi, Masakazu
    Dai, Kazuoki
    Nakao, Koichi
    Tarutani, Yasuhiro
    Taniguchi, Ryoji
    Nishikawa, Hideo
    Yamamoto, Yoshito
    Nakagawa, Yoshihisa
    Ando, Kenji
    Kobayashi, Koichi
    Kawai, Kazuya
    Hibi, Kiyoshi
    Kimura, Takeshi
    [J]. JACC-CARDIOVASCULAR INTERVENTIONS, 2019, 12 (07) : 637 - 647
  • [48] A 10-month angiographic and 4-year clinical outcome of everolimus-eluting versus sirolimus-eluting coronary stents in patients with diabetes mellitus (the diabedES IV randomized angiography trial)
    Maeng, Michael
    Baranauskas, Arvydas
    Christiansen, Evald Hoj
    Kaltoft, Anne
    Holm, Niels Ramsing
    Krusell, Lars Romer
    Ravkilde, Jan
    Tilsted, Hans-Henrik
    Thayssen, Per
    Jensen, Lisette Okkels
    [J]. CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2015, 86 (07) : 1161 - 1167
  • [49] Biodegradable polymer-coated thin strut sirolimus-eluting stent versus durable polymer-coated everolimus-eluting stent in the diabetic population
    Gasior, Pawel
    Gierlotka, Marek
    Szczurek-Katanski, Krzysztof
    Osuch, Marcin
    Roleder, Magda
    Hawranek, Michal
    Wojakowski, Wojciech
    Polonski, Lech
    [J]. CARDIOLOGY JOURNAL, 2021, 28 (02) : 235 - 243
  • [50] Drug-eluting stent implantation could be associated with long-term coronary endothelial dysfunction - Comparison between Sirolimus-Eluting Stent and paclitaxel-eluting Stent
    Shin, Dong Il
    Kim, Pum Joon
    Seung, Ki-Bae
    Kim, Dong Bin
    Kim, Mi-Jeong
    Chang, Kiyuk
    Lim, Sung Min
    Jeon, Doo Soo
    Chung, Wook Sung
    Baek, Sang Hong
    Lee, Man Young
    [J]. INTERNATIONAL HEART JOURNAL, 2007, 48 (05) : 553 - 567